Default Insulate an un-heated attached garage?

Howdy all!

I have an attached 2-car garage that shares 1.5 walls with my house. Due to the large quantity of attached surface area, I think it's worth insulating the garage to keep it a few degrees warmer. The exterior walls are drywalled, but there is no insulation in them, nor in the ceiling (which is also drywall). I have easy access to the ceiling from the attic, and the walls I would either poke holes in and blow in insulation, or tear out to add fiberglass. I don't really want to do that, though.

The garage door (16 foot) is insulated as well.

Worth it? Pros, cons? What about a vapor barrier on the exterior walls and ceiling? Also, the garage attic and house attic share the same airspace...there is no wall in the attic separating them. Should something be done about this?

Thanks



__________________
Quattro is offline  
 
Reply With Quote Quick reply to this message
Old 12-02-2009, 09:41 PM  
Launchpad
Member
 
Launchpad's Avatar
 
Join Date: Nov 2009
Posts: 41
Default

Definitly vapor barrier if you insulate.

What exactly do you plan on doing with the garage? Work shop, storage, finished space, etc... will determine if you should only insulate the shared walls with the house and/ or get the attic/ garage attic sealed up.



__________________
Launchpad is offline  
 
Reply With Quote Quick reply to this message
Old 12-03-2009, 10:31 AM  
Quattro
Massive Tool Belt
 
Join Date: Oct 2006
Posts: 262
Default

Well, it was drywalled when we bought it...but whoever drywalled it didn't bother to insulate as well. So, that makes a vapor barrier pretty difficult. Why is it necessary in a garage?

I won't be heating the garage, but it's getting SOME heat from the attached walls, so I thought it would be best to contain that if possible. Plus, heat from two cars could "last" a little longer with some insulation in the winter.

Any way to avoid the vapor barrier?

The shared walls are already insulated and double-drywalled.

__________________
Quattro is offline  
 
Reply With Quote Quick reply to this message
Old 12-05-2009, 01:14 PM  
Launchpad
Member
 
Launchpad's Avatar
 
Join Date: Nov 2009
Posts: 41
Default

Vapor barrier is used anytime you have moisture that is a problem or can be a problem. Anyplace where cold air and warm meet there will more than likely be condensation.

Personaly I would put a vapor barrier on the walls that are between your garage and living space. For me that would be just more of a preventive measure from mold and rot, but I'm a mold guy so naturally I see mold and water everywhere I look.

The rest of the garage should be fine without any vapor barrier. I personaly would do a vapor barrier just in case I would want to heat it in the future and build a man cave up in there, but if you just want to blow the insulation in there it should be fine as long as you don't have any moisture going on.

You could try knocking out an inspection hole and taking a look at some of the pre exisiting insulation you have. If it is black and crusty looking, you have moisture issues and I would definitly slap up the barrier.

__________________
Launchpad is offline  
 
Reply With Quote Quick reply to this message
Old 12-06-2009, 12:09 PM  
Nestor_Kelebay
Emperor Penguin
 
Nestor_Kelebay's Avatar
 
Join Date: Mar 2009
Location: Winnipeg, Manitoba
Posts: 1,844
Liked 2 Times on 2 Posts

Default

I fully expect the walls common to the house and garage will have insulation and vapour barrier on the house side.

I live in Winnipeg, Manitoba, which isn't all that much colder than New York or Wisconsin. I had a friend that insulated his unheated garage with expanded polystyrene foam (and he didn't use a vapour barrier), and when he'd park his car in the garage and leave it in there overnight, the garage would still be mild temperature in the morning. I don't know what he did in the garage ceiling, I expect he used expanded polystyrene there too. But, he'd park 500 pounds of hot steel in there every evening, and that kept the garage warm all night. But, that's just what he told me. I dunno if he was exagerating or not.

__________________
Nestor_Kelebay is offline  
 
Reply With Quote Quick reply to this message
Old 12-06-2009, 12:26 PM  
Launchpad
Member
 
Launchpad's Avatar
 
Join Date: Nov 2009
Posts: 41
Default

Now that is some serious insulating! I'd be tempted to make my family live in the garage to save some mony on heating with the engine of my F250!

__________________

[B][COLOR="Blue"]I was lying in bed, looking at the stars, and I wondered, where did my ceiling go?[/COLOR][/B]

Launchpad is offline  
 
Reply With Quote Quick reply to this message
Old 12-18-2009, 12:46 PM  
Quattro
Massive Tool Belt
 
Join Date: Oct 2006
Posts: 262
Default

Well, EPS (extruded polystyrene) more or less IS a vapor retarder (perm of ~1 for the 1.5 and 2" stuff, IIRC).

I guess I could use that stuff in the ceiling, since I have access to the attic side of the drywall. I'd have to rip the exterior wall drywall down to install that, though. Would rather just blow it in from a hole in the top of the wall...although I don't know if any fireblocking exists in these particular walls....I wouldn't think so.

Nothing sounds easy at this point. Why couldn't the previous owners have put in insulation before drywalling!!! Grrr..

And yes, as I said before, the walls that are shared with the interior have a vapor barrier (on the interior side). Oh, and the only moisture would be that of the melting snow/ice from 1 or 2 cars (we normally only drive one at a time).

__________________

Last edited by Quattro; 12-18-2009 at 12:49 PM.
Quattro is offline  
 
Reply With Quote Quick reply to this message
Old 12-18-2009, 04:15 PM  
inspectorD
Housebroken
HRT_MODERATOR.png
 
inspectorD's Avatar
 
Join Date: Dec 2005
Location: Litchfield, CT
Posts: 4,075
Liked 123 Times on 103 Posts
Likes Given: 302

Default well

Contact Nu-Wool :: Premium Cellulose Insulation :: Home Page they seem to be able to handle your issue, I have seen them do it before with a high dense blown in, not to mention it is made for use in fire wall construction.
BPI , and building science also recommends them. good luck.

also. try on the same page http://www.nuwool.com/BuildingOfficials/Specifications/VaporBarrier.aspx

__________________

Just My
Made in the

inspectorD is offline  
 
Reply With Quote Quick reply to this message
Old 12-18-2009, 05:51 PM  
Trim Plus
Junior Member
 
Join Date: Dec 2009
Posts: 9
Default

Hi,
My opinion is that if your not going to heat that area for living or working space your wasting your money. The two walls between the house and garage are more sealed or resistant to the outside enviroment than any othe wall of the house just because they have the dead air space of the garage itself. your getting more cold and wind penatration from all other the other exterior walls. If you have a cold air or draft issue, inspect the attic or crawl space for poor insulation job or air penatration.

Good luck.
Leo
trimplus(dot)biz

__________________
Trim Plus is offline  
 
Reply With Quote Quick reply to this message
Old 09-07-2010, 03:28 PM  
AtticCare
Junior Member
 
Join Date: Sep 2008
Location: Pflugerville
Posts: 19
Default

oh yeah, except that could make it worse using vapor barriers. Look up the DOE and see what they say about vapor barriers......THEY ARE BAD, NOT GOOD, BAD. Anybody still using them knows nothing about const. Vapor retarders, ok, vapor barriers BAD NEWS. I will find the many photos I have of the damage caused by vapor barriers, yours is just a picture of mold, these show you why walls and ceilings HAVE TO DIFFUSE MOISTURE.



__________________
AtticCare is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Insulate open rafter roof busyflyin Roofing and Siding 30 01-29-2012 11:30 PM
Best way to insulate concrete slab cibula11 Bricks, Masonry and Concrete 13 01-14-2010 05:27 PM
Should I Insulate It Myself? jholt29 General Home Improvement Discussion 1 08-09-2008 12:56 PM
Heated towel bar jgmorten General Home Improvement Discussion 0 05-16-2008 10:57 AM
heated bathroom floor elementx440 General Home Improvement Discussion 7 04-02-2008 02:12 PM