Old 01-11-2008, 10:47 AM  
Rincon
Member
 
Join Date: Jan 2008
Posts: 52
Default Hangin Drywall in Basement

First off I apologize that this is a repeat post, however I can't seem to find the one I had been reading. I am going to hang drywall on concrete block walls in the basement. They have been sealed with some type of paint/sealer. I plan on using some size of furring strip (please suggest) by screwing to the block with tapcon screws by first gluing with construction adhesive then drilling my pilot holes through the furring strips then into the block. Is this OK. At first I was planning on just running the furring strips vertically with a slight gap between the poured concrete floor and the furring strip, however I have read somewhere that I should run a baseplate strip against the floor and the ceiling joists for the furring strips to attatch to. Is it necessary to run the top and bottom plates, or can I just hang the furring strips vertically. Also will I save time by using some type of gun (please suggest type) for attaching the furring strips to the block.
Thank You for your time!



__________________
Rincon is offline  
 
Reply With Quote Quick reply to this message
Old 01-11-2008, 06:24 PM  
ToolGuy
Senior Member
 
ToolGuy's Avatar
 
Join Date: Nov 2007
Posts: 482
Default

The gun you're refering to is a powder actuated fastening nailer, and uses powder actuated fasteners (obviously ). A couple of popular brands are Remington and Hilti, but there are others. You'll have to look into which is the proper length fastener and the proper color coded loads to use, lest someone here comes along who knows.

Personally, I prefer tapcons or similar masonry screws. The threads make for a far superior hold. And it doesn't take that long to predrill and drive the screws once you get set up and going. A cordless impact driver works well for driving the tapcons.

It's common practice to do floating corners with drywall, but not using any adhesive or fasteners withing about 8 - 10 inches of the corner. This allows some slight flexibility in case of expansion/contraction. Even though, I'd still run a horizontal member across the top in case of impact, so the corner doesn't crack. Also along the bottom. It's not a lot of work or materials, and makes for a better quality job.

Here's a video that shows the floating corners technique...

http://hwtv.jlconline.com/ It's the second video if they haven't added more lately.



__________________

[COLOR="DarkRed"][B]~ ToolGuy ~[/B][/COLOR]

[I]Save money on tools at [URL="http://mytoolbox.net"]MyToolbox.net[/URL]
[/I]

ToolGuy is offline  
 
Reply With Quote Quick reply to this message
Old 01-11-2008, 07:10 PM  
inspectorD
Housebroken
HRT_MODERATOR.png
 
inspectorD's Avatar
 
Join Date: Dec 2005
Location: Litchfield, CT
Posts: 4,054
Liked 122 Times on 102 Posts
Likes Given: 286

Default Egads...

I love the idea but...shooting into block ...you will end up with alot of pieces. Tapcon masonary screws are the way you need to go. Drill and glue the boards on. What I use instead of wood is steel studs. They are less expensive and easier to install. Plus they do not get moldy.
Keep the sheetrock off the floor at least an inch or two. Use durarock for a filler at the bottom if you need to for trim.
Good luck.

__________________

Just My
Made in the

inspectorD is offline  
 
Reply With Quote Quick reply to this message
Old 01-14-2008, 10:32 AM  
Rincon
Member
 
Join Date: Jan 2008
Posts: 52
Default

Thank You both for your advice. Once I have completed ripping out and cleaning up the old I believe I am ready now that have the know how to procede. I will check out the video.

__________________
Rincon is offline  
 
Reply With Quote Quick reply to this message
Old 01-15-2008, 01:24 AM  
ToolGuy
Senior Member
 
ToolGuy's Avatar
 
Join Date: Nov 2007
Posts: 482
Default

Quote:
Originally Posted by Rincon View Post
Thank You both for your advice. Once I have completed ripping out and cleaning up the old I believe I am ready now that have the know how to procede. I will check out the video.
Keep us posted and feel free to throw all the questions you have our way.
__________________

[COLOR="DarkRed"][B]~ ToolGuy ~[/B][/COLOR]

[I]Save money on tools at [URL="http://mytoolbox.net"]MyToolbox.net[/URL]
[/I]


Last edited by ToolGuy; 01-15-2008 at 08:38 AM.
ToolGuy is offline  
 
Reply With Quote Quick reply to this message
Old 01-15-2008, 08:54 AM  
Rincon
Member
 
Join Date: Jan 2008
Posts: 52
Default

ToolGuy
One decision that I have been struggling with is the size of furring strip to use. I have been told 1x's or 2x's. I am hanging 1/2" DensArmor. When looking at screws I can't seem to find any 1" for attaching the drywall. I haven't gotten a chance to look at the metal studs yet. 1x's would not be as thick as 2x's and loss of 2" of floor space is is not a problem. I am a bit worried about my wall receptacles. I hope they left some slack inside the wall for me to extend them to be flush with the drywall. Any thoughts?
Thanks

__________________
Rincon is offline  
 
Reply With Quote Quick reply to this message
Old 01-15-2008, 12:19 PM  
ToolGuy
Senior Member
 
ToolGuy's Avatar
 
Join Date: Nov 2007
Posts: 482
Default

Quote:
Originally Posted by Rincon View Post
...I hope they left some slack inside the wall for me to extend them to be flush with the drywall. Any thoughts?
Thanks
Who is they? I thought you were starting with bare cement block walls (except for the sealer).

My prefered method is to use 2x2 studs laid flat against the block every 16" on center, and attached with construction adhesive and 2-1/2" tapcons, maybe 4 or 5 per stud. Any protrusions, such as an over filled mortar joint or a crooked block, I chop away with the claw of my hammer. Then I place 1-1/2" foam board insulation between the studs. I generally use 1-1/4" screws for the drywall, but 1-5/8" will do just as well. I never use 1" screws.

Anyway, this leaves 1-1/2" depth (thickness of a 2x2) for electrical boxes. If you need deeper boxes for any reason, you may nave to chop into the block a little to accomodate them.

What inspectorD says about using powder actuated fasteners is a good point - cement block doesn't stand up to the impact very well. But about metal vs wood, I prefer wood for a few reasons. Wood has better insulation value (metal has zero), wood is more rugged, and you can fasten stuff to wood, such as a heavy mirror or shelves. I know metal is quicker and cheaper, but these are at the bottom of my priorities. You may feel differently, just a matter of preference. I like wood.
__________________

[COLOR="DarkRed"][B]~ ToolGuy ~[/B][/COLOR]

[I]Save money on tools at [URL="http://mytoolbox.net"]MyToolbox.net[/URL]
[/I]

ToolGuy is offline  
 
Reply With Quote Quick reply to this message
Old 01-15-2008, 12:39 PM  
sherod
Junior Member
 
Join Date: Jan 2008
Posts: 1
Default Installers Drywall question

Parents are building new construction - basement comes with drywalled ceiling - after visiting site drywallers hung drywall and left Electrical Conduit showing (butted up to or cut out around it).

Thus drywall hung to floor joists and any conduit under joists still shows.

Question - is this normal - what should we say to the builder?

I understand sewage/ductwork under the joists - however shouldn't the conduit be covered using perhaps firring strips along the joists first then drywall installation so the conduit is covered?

__________________

Last edited by sherod; 01-15-2008 at 12:59 PM.
sherod is offline  
 
Reply With Quote Quick reply to this message
Old 01-15-2008, 05:09 PM  
kok328
Supporting Member
HRT_SUPPORTER.png
 
Join Date: Nov 2007
Location: Grand Blanc, MI
Posts: 2,185
Liked 105 Times on 92 Posts
Likes Given: 61

Default

butted up to or cut out around it must not look very good in terms of finish. I don't mind looking at conduit but, there shouldn't be any reason not to surface mount it or cover it up w/drywall. Drywallers don't mess w/electrical so they worked around it. I prefer to surface mount for future access w/o having to tear into the wall. Maybe you'll want to disconnect those circuits, pull back some wire, install a J-box up in the floor joists, splice a longer wire (probably only less than a foot, unfortunately) and run it to the original location. If your lucky, some cutback trimmings might be long enough to extend other circuits the few more inches you'll need.
Funny, I just noticed a commercial the other day where OwenCorning has insulated, mold/mildew resistant, paintable, removable panel kits for finishing basements.
__________________
kok328 is offline  
 
Reply With Quote Quick reply to this message
Old 01-15-2008, 07:13 PM  
ToolGuy
Senior Member
 
ToolGuy's Avatar
 
Join Date: Nov 2007
Posts: 482
Default

Quote:
Originally Posted by sherod View Post
Parents are building new construction - basement comes with drywalled ceiling - after visiting site drywallers hung drywall and left Electrical Conduit showing (butted up to or cut out around it).

Thus drywall hung to floor joists and any conduit under joists still shows.

Question - is this normal - what should we say to the builder?

I understand sewage/ductwork under the joists - however shouldn't the conduit be covered using perhaps firring strips along the joists first then drywall installation so the conduit is covered?
Hi Sherod,

Please start a new topic when posting about your own project. I don't wish to be a nag but it's not good forum etiquet to jump in a semi-related thread with your own questions. Also, will save a lot of confusion. At first I thought it was the original poster responding to my reply and almost asked what this has to do with the walls.


__________________

[COLOR="DarkRed"][B]~ ToolGuy ~[/B][/COLOR]

[I]Save money on tools at [URL="http://mytoolbox.net"]MyToolbox.net[/URL]
[/I]

ToolGuy is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Drywall meets door frame Stirator Windows and Doors 23 11-27-2012 12:25 PM
Basement advice RyanBruner Flooring 9 09-19-2008 10:02 PM
Soffit Drywall Repair LanceM Walls and Ceilings 6 02-26-2008 07:35 AM
Getting basement air into the return? Quattro HVAC 8 01-10-2008 07:51 AM
height of drywall and finished floor marklevinson1 Flooring 1 04-05-2007 04:18 PM