Hey all, it's the FNG with the kitchen remodel! WooHoo!

We bought a GE double wall oven to replace the electric range that's going bye-bye. Will I need to run an additional 220V line? I haven't opened the box yet to see what connections are required. Just looking into the future a bit. This will be one of the last things we install in the new kitchen.

Also, we're putting in a gas cooktop, also from GE. I'm almost positive this is an electric-light appliance. This should be regular 110V, right? Would I be OK breaking off one of the main kitchen outlets to feed this? I would think so, but I'm not 100% sure.

Lastly, what kind of pipe/tubing can I use to run the new gas line to the cooktop? I had a professional install a valved nipple off my gas main, but it's about 25 linear feet from where the cooktop will be in the kitchen. Can I use flexible the whole way, or should I plan on hanging iron pipe all the way to the kitchen floor, then using flexible the last 3-4 feet?

Thanks!



__________________
Quattro is offline  
 
Reply With Quote Quick reply to this message
Old 10-12-2006, 02:22 PM  
jeff1
Senior Member
 
jeff1's Avatar
 
Join Date: Mar 2006
Posts: 412
Liked 19 Times on 17 Posts
Likes Given: 1

Default

Hi,

Quote:
I haven't opened the box yet to see what connections are required.
You should...the install sheet inside will also have electircal tips and info.

Quote:
We bought a GE double wall oven to replace the electric range that's going bye-bye. Will I need to run an additional 220V line?
-Should- be able to reuse the original line from the free standing range.

Quote:
we're putting in a gas cooktop, also from GE. I'm almost positive this is an electric-light appliance. This should be regular 110V, right?
Correct.

Quote:
Would I be OK breaking off one of the main kitchen outlets to feed this? I would think so, but I'm not 100% sure.
All appliance manufactures suggest dedicated lines for each appliance.

Quote:
what kind of pipe/tubing can I use to run the new gas line to the cooktop?
Check local codes! Here ( Great White North ) with me we would run copper to the cooktop and probably use a 4 foot flex line there so the unit can be moved/lifted, if and when service would be required.

jeff.


__________________

Appliance Repair Aid
http://www.applianceaid.com/
I support MADD, please don't drink and drive!

jeff1 is offline  
 
Reply With Quote Quick reply to this message
Old 10-12-2006, 03:03 PM  
Quattro
Massive Tool Belt
 
Join Date: Oct 2006
Posts: 262
Default

Super!

Just realized that my current breaker panel is full. I might need to add some double "skinny" breakers to make room for the new dedicated line to the cooktop.

Interesting that I can *probably* use just the 1 line from the free-standing range to feed both new wall ovens. I'll dig into that box this weekend.

Thanks for the great answers!

__________________
Quattro is offline  
 
Reply With Quote Quick reply to this message
Old 10-12-2006, 05:06 PM  
jeff1
Senior Member
 
jeff1's Avatar
 
Join Date: Mar 2006
Posts: 412
Liked 19 Times on 17 Posts
Likes Given: 1

Default

Quote:
Interesting that I can *probably* use just the 1 line from the free-standing range to feed both new wall ovens.
Most have one main feed in and the power is split inside the oven to feed both ovens.

Quote:
I'll dig into that box this weekend
Great

jeff.
__________________

Appliance Repair Aid
http://www.applianceaid.com/
I support MADD, please don't drink and drive!

jeff1 is offline  
 
Reply With Quote Quick reply to this message
Old 10-14-2006, 12:04 PM  
glennjanie
Senior Member
 
Join Date: Mar 2006
Posts: 2,992
Liked 2 Times on 2 Posts

Send a message via AIM to glennjanie
Default

Hello Quattro:
In our area we would run the black iron pipe to the location, put a 1/4 turn valve on, then run a stainless steel flex line 3' or less to make the connection. I can't speak for the codes in your area but ours has outlawed copper gas lines several years ago.
Glenn

__________________
glennjanie is offline  
 
Reply With Quote Quick reply to this message
Old 03-07-2007, 02:36 PM  
Quattro
Massive Tool Belt
 
Join Date: Oct 2006
Posts: 262
Default

A follow up question here. I noticed my local Menards has 25-foot (and longer) length of flexible gas line. I like the idea of running this instead of iron pipe. Anyone have experience with this? Seems like a great alternative, but not if it is prone to leaks, etc.

No, I still haven't finished this project! :-) In fact, we're just now getting really started on it. The flooring is almost all the way up, the wall cabinets are all off, and this weekend we will be demolishing the cupboard soffits! They are attic-inclusive, so it's going to be messy and cold! But, I have lots of help, so we should be able to just rip out the existing drywall and framing, and replace the hole with new drywall in a matter of a couple hours. I hope.

Thanks

__________________
Quattro is offline  
 
Reply With Quote Quick reply to this message
Old 03-07-2007, 05:48 PM  
jeff1
Senior Member
 
jeff1's Avatar
 
Join Date: Mar 2006
Posts: 412
Liked 19 Times on 17 Posts
Likes Given: 1

Default

Quote:
No, I still haven't finished this project! :-)


Quote:
I noticed my local Menards has 25-foot (and longer) length of flexible gas line. I like the idea of running this instead of iron pipe
Might help...
http://www.gastite.com/homepage.php?pg=homeowners

jeff.


__________________

Appliance Repair Aid
http://www.applianceaid.com/
I support MADD, please don't drink and drive!

jeff1 is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
painted wall oven door chirp General Appliance Discussion 4 06-25-2009 11:41 AM
Installing a woodburner: Stovepipe through double brick wall crapbathroom Bricks, Masonry and Concrete 1 12-31-2008 10:12 PM
BIG retaining wall is on its way out mjordant Bricks, Masonry and Concrete 5 05-11-2008 05:10 PM
Opening wall, don't think it's load bearing? CZSteve Walls and Ceilings 8 01-15-2008 12:45 AM
PWF Foundation Wall Repair Questions gc9713 Framing and Foundation 1 11-15-2007 10:09 AM