Hello,

This is my utility room.

I'm wondering how I can fix this? After removing the water heater the HVAC contractor discovered there were holes in the plastic pan, and the cement floor had all but disintegrated. You can barely notice the plywood below? It's ready to give way.

One suggestion was to refill with cement and put a new piece of plywood, then put the new water heater on top. The only catch is, that this utility room sits over top another utility room…My neighbors.

I don't know if any of you live in a condo, but this is something I have to consider before trying anything. I'm trying to get the condo association to cover this since there was no leak in the water heater.

If I end up having to fix this, I want to do it right.

Can anyone help?

Thanks kindly.



img_2841.jpg   img_2839.jpg  
__________________
WingNut is offline  
 
Reply With Quote Quick reply to this message
Old 02-22-2012, 06:58 AM  
aureliconstruction
Contractor
 
aureliconstruction's Avatar
 
Join Date: Dec 2011
Location: Boston, MA
Posts: 11
Default

The proper way of doing a utility floor from the get go is to put in a floor drain. Thee floor drain is extra water prevention. The floor drain can go in the basement and drain in a sink, depending on your local codes or state codes. Usually they do not want it to drain into a sewer. If installing a floor drain is not possible, have a sheet metal company fabricate a copper pan that is a few inches high. Do a mud job and tile it. Then, just for ****s and giggles, install a pump that pumps any eventual leak into a drain, washer discharge or wherever possible. The pan and pump would be the cheaper route, but both would work great.



__________________

[url]http://www.aureliconstruction.com[/url]

aureliconstruction is offline  
 
Reply With Quote Quick reply to this message
Old 02-22-2012, 07:09 AM  
WingNut
Junior Member
 
Join Date: Feb 2012
Posts: 3
Default utility room - cement flooring 2

Now I can present this to my property manager with confidence. I am going to wait for 2 more responses so I'm loaded with ammo. If all responses agree, then I'll be good to go.

If the condo assoc. won't do it and I have to, then so be it. Don't mind learning something new.

Thank you very much Aureliconstruction.

WingNut

__________________
WingNut is offline  
 
Reply With Quote Quick reply to this message
Old 02-23-2012, 12:37 AM  
BridgeMan
Senior Member
 
BridgeMan's Avatar
 
Join Date: Aug 2011
Location: Cottage Grove, Oregon
Posts: 738
Liked 75 Times on 67 Posts

Default

The concrete (not cement--cement is a grey, fluffy powder) floor in the photos is showing both surface scaling and delamination, in addition to the broken-out area adjacent to the plumbing drain line. Not sure a floor drain is the way to go, and I've never seen one in the dozen houses I've owned and lived in since 1969. A much more appropriate correction involves repairing the floor surface by removing and replacing all deteriorated concrete, plugging the open area at the pipe, then installing an off-the-shelf galvanized steel drain pan under the water heater. Since the floor is a structural component of your condo, but not an exterior element, your condo association is not likely to be responsible for the repairs. Depends on the fine-print wording of your condo agreement.

While you're at it, you need to do something about all of the electrical wiring code violations visible in the pix.

__________________

Last edited by BridgeMan; 02-23-2012 at 12:42 AM.
BridgeMan is offline  
 
Reply With Quote Quick reply to this message
Old 02-23-2012, 05:15 AM  
inspectorD
Housebroken
HRT_MODERATOR.png
 
inspectorD's Avatar
 
Join Date: Dec 2005
Location: Litchfield, CT
Posts: 4,075
Liked 123 Times on 103 Posts
Likes Given: 301

Default

Quote:
Originally Posted by BridgeMan View Post
While you're at it, you need to do something about all of the electrical wiring code violations visible in the pix.
The wiring exposed is for the electric water heater. Other than that I see no violations with the low voltage wires.
You also have a plumbing connection for the pan already at the floor level, I would continue with this setup, If you change it and there is a problem, you may be responsible for the whole thing if anything does happen in the future to the unit below. Also I would make sure your insurance company covers any of this in the future.
As far as the condo association? Is it written in your contract with the fees you pay for?
Good luck.
__________________

Just My
Made in the

inspectorD is offline  
 
Reply With Quote Quick reply to this message
Old 02-23-2012, 02:08 PM  
WingNut
Junior Member
 
Join Date: Feb 2012
Posts: 3
Default

Aureli Construction, BridgeMan, and InspectorD,

Thank you for all your responses. Very quick!

As it turns out, the condo association did the repair and cover the cost. Kid gloves with the property manager, who turned out to be a swell guy.

The white pvc pipe at the top left of the crater, continues from my utility room on through the two utility rooms below me, then drains out at the bottom.

The crater was cleaned out and refilled with a quick drying cement. I'm letting it dry through Sunday. The test will be putting the water heater on top of this Monday morn. Cross my fingers.

Contractors and property manager are still scratching their heads as to why the cement deteriorated so badly. Seems like my neighbor below may be having the same problem.

Thanks again to you all!

WingNut



img_2842.jpg   img_2843.jpg  
__________________
WingNut is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Adding a utility Sink ME87 Plumbing Forum 38 11-23-2011 09:59 AM
Can I temporarily connect my dishwasher in utility room while remodeling kitchen? ilyaz General Home Improvement Discussion 2 01-19-2010 07:19 AM
Wood Flooring over cement slab? EMayo Flooring 3 02-14-2008 12:25 PM
What do you hate most about your utility knife? chris1010 Tools 13 01-13-2008 08:35 PM
Ridgid Miter Saw Utility Vehicle - $99 MoJoe Tools 3 03-15-2006 03:45 PM