Old 12-21-2009, 03:53 PM  
plumber red
Junior Member
 
Join Date: Dec 2009
Posts: 2
Default bathroom re-do Q's

hi there

re-doing a bathroom upstairs which was badly renovated in the first place. 1950 house - cast iron stack, ABS/copper in bathroom

bathroom is 10x5 the tub is located with a 10' run to the main stack. the sink drains into the main stack and the toilet drains into the main stack. the sink is vented as is the tub at source.

the drain from the tub currently is 1.5" running striaght for 8' then it hangs a 90 degree bend and goes for 2 more feet to the main stack. it is vented at the 90 as well.

TUB DRAINS SLOOOOOOOOOOOOOOOOW

so i was thinking that the slope of the drain pipe is low, so increasing it to 2" might help but i have a few q's before diving in

-if my bathtub drain hole is 1.5" will it make any difference eif the pipe is 2"?

-do i NEED 2" or should 1.5" work? (wondering if there is an issue where it ties into the cast stack)

- can a toilet 4" waste pipe have a 90 degree bend in it laying horizontal and if so does it need to be a long sweeping one

- does a vent care if it has a 90 degree bend in it versus two 45's

- can i use flexible water supply hoses (typical for sinks) to supply a shower? thinking from the shutoff to the actual shower control so a run of 10" or so - otherwise i have to reroute the existing copper

thanks



__________________
plumber red is offline  
 
Reply With Quote Quick reply to this message
Old 12-27-2009, 07:12 PM  
DUNBAR
Master Plumber
 
DUNBAR's Avatar
 
Join Date: Jun 2009
Location: Northern Kentucky/Greater Cincinnati Area, Kentucky
Posts: 23
Default

Quote:
Originally Posted by plumber red View Post
hi there

re-doing a bathroom upstairs which was badly renovated in the first place. 1950 house - cast iron stack, ABS/copper in bathroom

bathroom is 10x5 the tub is located with a 10' run to the main stack. the sink drains into the main stack and the toilet drains into the main stack. the sink is vented as is the tub at source.

the drain from the tub currently is 1.5" running striaght for 8' then it hangs a 90 degree bend and goes for 2 more feet to the main stack. it is vented at the 90 as well.

TUB DRAINS SLOOOOOOOOOOOOOOOOW

so i was thinking that the slope of the drain pipe is low, so increasing it to 2" might help but i have a few q's before diving in

-if my bathtub drain hole is 1.5" will it make any difference eif the pipe is 2"? NOPE

-do i NEED 2" or should 1.5" work? (wondering if there is an issue where it ties into the cast stack) 1.5" will work, move the vent within 3'-6" of the drain opening

- can a toilet 4" waste pipe have a 90 degree bend in it laying horizontal and if so does it need to be a long sweeping one YES, AND NO

- does a vent care if it has a 90 degree bend in it versus two 45's No flat venting under 42", must be 45's to avoid clogging the vent
- can i use flexible water supply hoses (typical for sinks) to supply a shower? thinking from the shutoff to the actual shower control so a run of 10" or so - otherwise i have to reroute the existing copper Those lines you're mentioning are made for open locations only. Hard pipe those connections

thanks

Northern Kentucky Plumbers


__________________

Last edited by DUNBAR; 12-27-2009 at 11:50 PM.
DUNBAR is offline  
 
Reply With Quote Quick reply to this message
Old 01-03-2010, 07:41 AM  
plumber red
Junior Member
 
Join Date: Dec 2009
Posts: 2
Default

great, thanks for the info.

another question

does a toilet need to be vented additionally if it sits 30" from the main vertical stack

__________________
plumber red is offline  
 
Reply With Quote Quick reply to this message
Old 01-05-2010, 11:35 PM  
DUNBAR
Master Plumber
 
DUNBAR's Avatar
 
Join Date: Jun 2009
Location: Northern Kentucky/Greater Cincinnati Area, Kentucky
Posts: 23
Default

Quote:
Originally Posted by plumber red View Post
great, thanks for the info.

another question

does a toilet need to be vented additionally if it sits 30" from the main vertical stack


In Kentucky on 3" I believe you can go as far as 5' from toilet to vent. I'd have to get my plumber's bible out to confirm that but I'm pretty sure that's the maxium.

Depending on where you are located dictates the distance on a toilet.



Northern Kentucky Plumbers
__________________
DUNBAR is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Bathroom Help!!!! Vikeologist Flooring 8 03-10-2012 01:41 AM
Add Bathroom DIY cibula11 Plumbing Forum 4 09-13-2009 06:59 PM
bathroom odour stevelygee General Home Improvement Discussion 5 03-29-2007 08:25 AM
Bathroom Floor dennisc31 General Home Improvement Discussion 5 03-16-2007 08:41 AM