DIY Home Improvement, Remodeling & Repair Forum > DIY Home Improvement > Plumbing Forum > can i cap my tub overflow pipe?





Reply
 
LinkBack Thread Tools Search this Thread Display Modes
Old 12-28-2012, 05:11 PM  
DanTheMan
Junior Member
 
Join Date: Dec 2012
Posts: 9
Default can i cap my tub overflow pipe?

I am replacing the tub in my bathroom remodel, and the one i bought unknowingly was one without the overflow hole.

After reading this:

http://wiki.answers.com/Q/Are_bathtub_overflow_drains_required

It seems it is not necessary, so i bought a drain that pops up and down to close it to just bypass that trip lever. Then i took off the top half of the trip lever housing/overflow pipe and put a pvc cap over it (rational being this long pipe hits the tub where the hole should be and puts the whole assembly at a bad angle for the drain). After talking to my dad he was wondering if air needed to get through the overflow pipe to help it drain. Just confirming that there wont be an issue, i dont foresee one since the pipe will fill up to the level of the tub water anyway when you hit the drain...



__________________
DanTheMan is offline  
 
Reply With Quote Quick reply to this message
Old 12-28-2012, 06:21 PM  
nealtw
Senior Member
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 7,675
Liked 538 Times on 488 Posts
Likes Given: 997

Default

All of that may be true but people do forget that they have water filling the tub. One mistake could be very expensive. Why not just drill the hole? And welcome to the site.



__________________
nealtw is online now  
 
Reply With Quote Quick reply to this message
Old 12-28-2012, 06:49 PM  
CallMeVilla
Senior Member
 
CallMeVilla's Avatar
 
Join Date: Feb 2010
Location: San Diego
Posts: 1,054
Liked 266 Times on 216 Posts
Likes Given: 104

Default

Your drain must be connected to the ent stack (pipe) to operate properly. My guess is that it is. This will allow proper drainage. If you can be 110% sure you will never let the tub overflow, then you can live without the overflow pipe . . . but it is there for a good reason.

__________________
CallMeVilla is offline  
 
Reply With Quote Quick reply to this message
Old 12-28-2012, 07:19 PM  
DanTheMan
Junior Member
 
Join Date: Dec 2012
Posts: 9
Default



just so we are on the same page the vertical pipe that goes to the overflow there is a junction where the two connect and that is where i capped it with the pvc cap.


I have not drilled out a hole bc i am worried about it not being lined up well and ruining my tub and possibly flaking off the coating on the inside of the tub. If it is possible i could potentially hook up the pipe again. i had some free time today so i did that while i wait on a plumber to install the delta shower valve.

I have all the drywall ripped off around the tub so i can always just pick the tub up again to get in there if i need to.
__________________
DanTheMan is offline  
 
Reply With Quote Quick reply to this message
Old 12-28-2012, 07:22 PM  
Wuzzat?
Senior Member
 
Wuzzat?'s Avatar
 
Join Date: Jan 2010
Posts: 1,822
Liked 95 Times on 86 Posts
Likes Given: 53

Default

One other option is a water level detect circuit that cuts off the water flow with a solenoid valve. The water sensor could be under the tub or on the outside surface of the tub but this is hi-tech, expensive, may be impractical and maybe cost more than repairing water damage.

My tub fills at 6 GPM but I never put this to the test. I guess I should also try it with 2 GPM basins. I'm on city water.

__________________

Last edited by Wuzzat?; 12-28-2012 at 07:30 PM.
Wuzzat? is offline  
 
Reply With Quote Quick reply to this message
Old 12-28-2012, 07:43 PM  
DanTheMan
Junior Member
 
Join Date: Dec 2012
Posts: 9
Default

oh you mean vent stack right? yeah there are like three drain pipes i think that go into the vent stack before going out to the septic tank and one is for the tub and toilet in there.

__________________
DanTheMan is offline  
 
Reply With Quote Quick reply to this message
Old 12-29-2012, 09:06 AM  
CallMeVilla
Senior Member
 
CallMeVilla's Avatar
 
Join Date: Feb 2010
Location: San Diego
Posts: 1,054
Liked 266 Times on 216 Posts
Likes Given: 104

Default

It's funny how language can fail . . . The way I hear you, you have capped the overflow pipe inside the wall. (See my modified pic below) This tells me your vent stack is NOT piped above the overflow pipe. One of the key principles in plumbing is "air behind water" which means drainage works best when there is free air feeding into the drain line at or near the source.

Your tub should have a p-trap that connects below the drain pipe. From there the drain will travel a bit but a vent stack (pipe) has to intersect within 36" to guarantee good srainage flow. Since you have the wall open, you should check.

The cap on the overflow should not impede your air flow as long as the vent stack is not above it as part of the overflow piping.



__________________
CallMeVilla is offline  
 
Reply With Quote Quick reply to this message
Old 12-29-2012, 01:01 PM  
Wuzzat?
Senior Member
 
Wuzzat?'s Avatar
 
Join Date: Jan 2010
Posts: 1,822
Liked 95 Times on 86 Posts
Likes Given: 53

Default

Your link has taught me something.

When I flush slow-going drains with a garden hose plus adaptors that go from aerator threads to garden hose threads, I never flush the overflow.
Now I find that, out of three basins two have clogged overflows and the remaining overflow cannot keep up with 2 GPM.
All drains can keep up, though.

And I have some evidence that the bathtub overflow is clogged.

Possibly these overflows are there to humor us.

__________________
Wuzzat? is offline  
 
Reply With Quote Quick reply to this message
Old 12-29-2012, 03:01 PM  
CallMeVilla
Senior Member
 
CallMeVilla's Avatar
 
Join Date: Feb 2010
Location: San Diego
Posts: 1,054
Liked 266 Times on 216 Posts
Likes Given: 104

Default

Here is another pic of a typical tub, toilet and lav piping arrangement. It can help anyone who is plumbing a bathroom. Notice there is NOT overflow piping because this diagram features a shower floor setup. However, the physics of the drainage is identical for a tub or a shower.

Notice, also the p-trap and THEN the vent stack attachment. That setup would work fine for Dan-the-Man.



__________________
CallMeVilla is offline  
 
Reply With Quote Quick reply to this message
Old 12-29-2012, 06:44 PM  
DanTheMan
Junior Member
 
Join Date: Dec 2012
Posts: 9
Default

Ok so it looks like everything will work out bc you are right shower only systems would not have that overflow pipe. The p trap is right below the sub floor and there is about three feet or so of PVC pipe that dumps into the big pipe running to the septic where other pipes converge and the cent stack goes up at that point. Thanks for that picture.



__________________
DanTheMan is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Overflow Leaking?! TDP Plumbing Forum 8 12-05-2012 10:59 AM
old bath overflow removal- need help dorego Plumbing Forum 9 02-25-2012 06:03 PM
Need guidance in attaching new tub to old drain and overflow Please amodoko Plumbing Forum 3 12-07-2011 12:07 PM
sink overflow cap garbert Plumbing Forum 1 11-27-2011 03:12 PM
bathtub overflow?? Rob99 Plumbing Forum 10 11-08-2009 05:30 PM