DIY Home Improvement, Remodeling & Repair Forum > DIY Home Improvement > Plumbing Forum > Copper Tube Soldering Problems




Reply
 
LinkBack Thread Tools Search this Thread Display Modes
Old 07-04-2011, 08:49 PM  
1victorianfarmhouse
Senior Member
 
Join Date: Feb 2010
Posts: 150
Liked 9 Times on 5 Posts

Default Copper Tube Soldering Problems

Okay, so I'm in the process of replacing some old valves in preparation for adding a new water softener bought from a contributor on this list.

I'm new at soldering, but have been soldering with electrics for decades, so it's not that different. Of more than three dozen joints I've made, I have two that are leaking. One leak is horizontal, the other is vertical. Not huge, but enough, especially since they are on the line that goes from the well to the softener.

With every joint I sanded the tubing and fluxed both the inlet and outlet. I use a basic propane torch and solder, both bought at Menards.

I heat up the joint, then let the solder flow into it, just like I've seen on several videos. On these two joints, after they leaked, I resanded, cleaned them with alcohol and refluxed them, but did not take them apart. It seems that no matter how hot the joint gets (other joints six inches away start to soften) , the solder doesn't want to flow into it.

What happened? Do I need to remove these two and start over from scratch?

Is it contaminated somehow?

Thanks!

vince



__________________
1victorianfarmhouse is offline  
 
Reply With Quote Quick reply to this message
Old 07-04-2011, 10:20 PM  
Blue Jay
Senior Member
 
Blue Jay's Avatar
 
Join Date: Jun 2008
Location: La Rue, Ohio
Posts: 250
Liked 10 Times on 10 Posts
Likes Given: 16

Default

Sounds like you have water in the line where you are trying to solder. Need to get all water away from the area (at least 3" on vertical) not a torch made that will the joint hot enough/



__________________
Blue Jay is offline  
 
Reply With Quote Quick reply to this message
Old 07-04-2011, 10:33 PM  
1victorianfarmhouse
Senior Member
 
Join Date: Feb 2010
Posts: 150
Liked 9 Times on 5 Posts

Default

Interesting, and thanks!

I noticed the leaks once I turned the water on, should be interesting trying get the water out of the pipe now, it's about 6" vertical and 18" horizontal.

But now i know what to do...

vince

__________________
1victorianfarmhouse is offline  
 
Reply With Quote Quick reply to this message
Old 07-05-2011, 04:53 AM  
kok328
Supporting Member
HRT_SUPPORTER.png
 
Join Date: Nov 2007
Location: Grand Blanc, MI
Posts: 2,171
Liked 102 Times on 89 Posts
Likes Given: 61

Default

You need to take them apart, clean up the mating surfaces and reapply the flux.
It's the flux that draws the solder into the joint.
P.S.- I always use MAPP gas instead of propane, it heats the joint up faster so as to not allow the heat to travel to previously soldered joints.

__________________
kok328 is offline  
 
Reply With Quote Quick reply to this message
Old 07-06-2011, 04:15 PM  
JoeD
Contractor
 
Join Date: Mar 2006
Location: Welland, Ontario
Posts: 936
Liked 91 Times on 76 Posts

Default

You sanded the tubing. You should also sand the inlet side. Both surfaces need to be cleaned.

__________________
JoeD is offline  
 
Reply With Quote Quick reply to this message
Old 07-06-2011, 05:05 PM  
Redwood
Certified Lunatic
 
Redwood's Avatar
 
Join Date: Apr 2009
Location: Olde Tyme, Connecticut
Posts: 887
Default

Both surfaces need to be clean and fluxed and there can be no water present. It also helps to have an open valve to allow the pressure buildup from heating to escape....

Once wet it has to come apart for a complete do over....

__________________
Redwood is offline  
 
Reply With Quote Quick reply to this message
Old 07-06-2011, 08:55 PM  
1victorianfarmhouse
Senior Member
 
Join Date: Feb 2010
Posts: 150
Liked 9 Times on 5 Posts

Default

All fixed now. Thanks for the info! I did sand the tubing, both the inlet and outer, but didn't make it clear. The water got into the tubing when I removed an old pipe and some water spilled out of it onto the surface I was working on; I didn't realize some had gotten into the pieces I had prepped for assembly.

vince

__________________
1victorianfarmhouse is offline  
 
Reply With Quote Quick reply to this message
Old 07-07-2011, 09:41 PM  
Bevix
Junior Member
 
Join Date: Mar 2011
Location: Takoma Park, Maryland
Posts: 3
Default

Here's a tip for the water issue in horizontal lines:

Take some white bread (not that hippie 28 grain type--the bad for you Wonder bread type) and stuff a small plug in the line--not too much and not too tight. It will temporarily keep any water away from your joints and will flush right out with no issues once the water is back on. Works like a charm.

For vertical lines, I usually don't have much problem. The key is to open to lowest valve in your house (usually an outside hose bib) so that the system can drain completely. Open several faucets throughout the house, too. That usually completely drains the system.

__________________
Bevix is offline  
 
Reply With Quote Quick reply to this message
Old 07-07-2011, 10:35 PM  
Redwood
Certified Lunatic
 
Redwood's Avatar
 
Join Date: Apr 2009
Location: Olde Tyme, Connecticut
Posts: 887
Default

I've never shared my lunch with a pipe yet....

__________________
Redwood is offline  
 
Reply With Quote Quick reply to this message
Old 07-08-2011, 12:59 AM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 9,439
Liked 746 Times on 666 Posts
Likes Given: 1303

Default

bread, I'm sure the health dept. would love that.



__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Basic Soldering of copper pipe Nestor_Kelebay Plumbing Forum 37 03-02-2013 01:50 PM
Solar tube lighting brasilmom Green Energy and Sustenance Living 3 04-14-2009 08:32 PM
Heat Tube dougnsue General Home Improvement Discussion 5 04-10-2009 01:02 PM
shower plumbing / soldering problems Christian Plumbing Forum 5 05-02-2008 06:25 PM
Risk of Explosion When Soldering Drain Pipe? travelover Plumbing Forum 3 10-22-2007 04:39 PM