Old 07-17-2012, 07:40 PM  
joecal
Junior Member
 
Join Date: Jun 2012
Location: Los Angeles, California
Posts: 15
Default crossover

Hello. I'm having a problem with hot water coming out of my cold water taps at times (even ones that have two handles). From what I've read, single handle faucets and valves that have become defective can cause this. Sometimes, once it starts, the hot water doesn't finally cool down after I let it run for a while. Other times, it'll cool down after a while. I'm not talking warm but hot water. I have a hot water heater and two showers with single handle valves (one is a moen) and I have a single handle Kohler forte faucet with one of those heads you can pull away from the unit. Since my Moen shower valve was leaking anyways I had my plumber replace the cartridge and now it no longer leaks. He felt inside the pipe where the cartridge goes into before he put it in to see if he could feel any grooves (which would allow water to pass he said) but said it felt ok. The new valve he put in was plastic. However, my crossover troubles still continue. I just got done turning on the kohler kitchen faucet and the water was coming out the tap was hot so i reached under the sink and felt the hot water line but it was cool, and the cold water line was hot. So it seems to me that the hot water wasn't coming from the hot water side of the kohler unit but from the cold water line itself. This leads me to believe that the odds are against there being a problem with the kohler faucet. However, that still leaves one other shower single handle valve (which I took a photo of and my local plumber supply store said was plastic and which they claim wouldn't be a cause of crossover since it was plastic). Is there any other trouble shooting anyone can recommend or any way that I can check the other shower valve (which is enclosed so i can't feel the hot and cold water lines. Also, I felt both lines feeding into my hot water heater and while the hot water line out was warm the cold water line in was also warm. Is it possible that the hot water may be coming back out of the hot water heater and going into my cold water line? Also, I have a clothes washer with a hot and cold line but it has two valves, one for the hot water and one for the cold water so it didn't seem possible to me that crossover could be happening there? Any suggestions would be much appreciated. Thank you.



__________________
joecal is offline  
 
Reply With Quote Quick reply to this message
Old 07-17-2012, 08:17 PM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 9,893
Liked 813 Times on 726 Posts
Likes Given: 1404

Default

If you have not run any water for a while, all water will be cool when you first turn it on. Run the cold water in the kitchen until it gets warm and then feel the the hoses at the washer and turn on each cold water in the house one at a time. Wherever you find instant hot water that will be the guilty guy.



__________________
nealtw is online now  
 
Reply With Quote Quick reply to this message
Old 07-17-2012, 08:58 PM  
joecal
Junior Member
 
Join Date: Jun 2012
Location: Los Angeles, California
Posts: 15
Default

Hello Nealtw, thanks for the response. I'll give that a try. If I understand what you're saying tho, it's possible that even a regular two handled faucet could be to blame? Thankss again, Joe

__________________
joecal is offline  
 
Reply With Quote Quick reply to this message
Old 07-18-2012, 03:07 PM  
joecal
Junior Member
 
Join Date: Jun 2012
Location: Los Angeles, California
Posts: 15
Default

nealtw, I did what you recommended two times. It took a while because most of the time the water comes thru cool as it should through the kitchen faucet and other faucets. Two times now it's come thru hot at the kitchen faucet. Both times this happened I felt both lines to this faucet and the hot water line felt cool but the cold water line felt warm. So I went and checked the cold water line into the washer and it was cool. I turned on all the other faucets in my bathrooms and utility room and the showers and they all felt cool. When I checked at my cold water line into my water heater it was hot. Is it possible that the hot water may be backing out of the hot water heater into the cold water line at times? Thankss, Joe

__________________
joecal is offline  
 
Reply With Quote Quick reply to this message
Old 07-18-2012, 04:18 PM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 9,893
Liked 813 Times on 726 Posts
Likes Given: 1404

Default

Do you or have you had a circulating pump hooked up?

__________________
nealtw is online now  
 
Reply With Quote Quick reply to this message
Old 07-18-2012, 11:26 PM  
joecal
Junior Member
 
Join Date: Jun 2012
Location: Los Angeles, California
Posts: 15
Default

nealtw, don't know. From what I've read that's a pump that provides nearly instant hot water. But we've never had instant hot water in the 8 months that we've lived in this house so if there is such a pump it's never worked. I looked in the closet where my water heater is at but I don't see anything other than the cold water line into the top of the water heater and the hot water line out the top and one other line coming out the side of the heater that I figured was the pressure release valve with a pipe that goes into my wall. Is there any way I can check myself to see if I have one of these circulating pumps? Thanks, Joe

__________________
joecal is offline  
 
Reply With Quote Quick reply to this message
Old 07-18-2012, 11:38 PM  
joecal
Junior Member
 
Join Date: Jun 2012
Location: Los Angeles, California
Posts: 15
Default

nealtw, ok I looked on line and I see that that device is installed on the hot water line near where it exits the hot water heater and then there are connecting devices that you put under a sink which connects the hot and cold water. I don't have anything like this on my hot water line out of my hot water heater.

__________________
joecal is offline  
 
Reply With Quote Quick reply to this message
Old 07-19-2012, 12:06 AM  
joecal
Junior Member
 
Join Date: Jun 2012
Location: Los Angeles, California
Posts: 15
Default

nealtw, i just took a good look under my kitchen sink and there is a box called an in sinkerator instant hot water dispenser. Now I didn't think it was an issue since I unplugged it when we moved in 8 months ago. I see it has a line from the cold water side but if it's unplugged I don't see how it could heat up the cold water. And as far as I see I don't see anyplace where the hot water line feeds into it.

__________________
joecal is offline  
 
Reply With Quote Quick reply to this message
Old 07-19-2012, 01:05 AM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 9,893
Liked 813 Times on 726 Posts
Likes Given: 1404

Default

As you might guess, I am quickly running out of questions to ask. Turn off the infeed to the tank, do you get cold water then? If yes turn it back on and turn of the hot stop under every sink and washer and see if that corrects it at the showers.
It must be nice sitting on a worm toilet.

__________________
nealtw is online now  
 
Reply With Quote Quick reply to this message
Old 08-07-2012, 10:47 AM  
Garmo
Junior Member
 
Join Date: Sep 2011
Location: , WI
Posts: 6
Default

JoeCal -
it is quite possible that your internal parts to one of your single hand faucets (shower would be most likely based on flow volume) is cracked inside allowing the water to cross over. You said one is Moen, do you know who the mfg is on the other one? Since the Moen parts were just replaced i would rule out that one, unless that is when the issue began.



__________________
Garmo is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On