DIY Home Improvement, Remodeling & Repair Forum > DIY Home Improvement > Plumbing Forum > Depth of drain pipe under slab




Reply
 
LinkBack Thread Tools Search this Thread Display Modes
Old 06-09-2006, 08:06 PM  
Mudball
Member
 
Join Date: May 2006
Posts: 53
Default Depth of drain pipe under slab

I have one ditch dug and one more to go for the 4" drain pipes under the slab. I have more trim digging to do depending on what the distance should be between the top of the horizontal 4" drain and the bottom of the slab. My plan is to dig the ditch deep enough to put a thin layer of sand in the ditch for the pipe to lay on and then cover the pipe in more sand and small river rock (pee gravel)...Im shooting for a 3" space between the top of the drain pipe and where the bottom of the slab will sit. Does this sound like enough space ?
Thanks



__________________
Mudball is offline  
 
Reply With Quote Quick reply to this message
Old 06-09-2006, 08:49 PM  
glennjanie
Senior Member
 
Join Date: Mar 2006
Posts: 2,992
Liked 2 Times on 2 Posts

Send a message via AIM to glennjanie
Default

That's perfect, mudball! I think you will come out OK on this job. May I revisit the fall issue? You said the sewer will be 60 feet long, National and Kentucky Plumbing code say 1/4 inch per foot is acceptable. If it falls 1/4" per foot you have 60 quater inch drops. 60/4=15 inches or some of us need to sit down with a tape measure and count the 1/4" increments in 15"; just to see if you come up with 60. I rest my case.
Glenn



__________________
glennjanie is offline  
 
Reply With Quote Quick reply to this message
Old 06-10-2006, 03:55 AM  
Mudball
Member
 
Join Date: May 2006
Posts: 53
Default

Thanks glennjanie. It looks like we are going to be sitting perfect on the correct amount fall for the pipe.
When you said..."That's perfect, mudball! I think you will come out OK on this job." Did you mean that Im ok on the first question as far as on the amount of distance between the top of the pipe and the bottom of the slab ?
Im actually referring to the highest (most shallow) the beginning part of the pipe because after that, the pipe will be dropping deep enough under the slab with plenty of gravel over it to protect it from the slab. Im concerned about the highest part of the pipe. Does that make sense
Sorry if I dont make questions very clear. I would say its because of my lack of experience and/or terminoligy...but Im learning. So 3" is ok ?
Thanks

__________________
Mudball is offline  
 
Reply With Quote Quick reply to this message
Old 06-10-2006, 09:55 AM  
glennjanie
Senior Member
 
Join Date: Mar 2006
Posts: 2,992
Liked 2 Times on 2 Posts

Send a message via AIM to glennjanie
Default

Good Morning Mudball:
Yes, the begining point being 3" below the bottom of the concrete is perfect. You can carry a 1/8" per foot fall from there to the foundation line. Then, when you get outside the foundation you need to install a test tee so you can seperate the building drain for testing. Kentucky code requires 18" cover over the sewer outside the foundation line which can be achieved with a 45 degree drop. Then the 1/4" per foot fall would be carried from there to the septic tank or other point of disposal. If your ground falls faster than that, you can make more 45 degree drops to keep the sewer 18" below the ground.
Glenn

__________________
glennjanie is offline  
 
Reply With Quote Quick reply to this message
Old 06-10-2006, 07:34 PM  
Mudball
Member
 
Join Date: May 2006
Posts: 53
Default

Thanks glennjanie. That sounds great. I'm so tired right now
Is has been a very hard hot long day. I guess I'll get it done soon. Thanks for the help. It looks like everything is going to be alright...in time



__________________
Mudball is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Moving a Kitchen sink - vent lines and drain pipe paulfavre Plumbing Forum 4 10-13-2008 01:05 PM
rebuilding shower floor gregrph General Home Improvement Discussion 7 05-29-2008 10:27 PM
Risk of Explosion When Soldering Drain Pipe? travelover Plumbing Forum 3 10-22-2007 04:39 PM
Floor Drain Question for GlennJanie manhattan42 Plumbing Forum 2 07-17-2006 11:46 AM
Run new drain through or around slab KeninCharlotte Plumbing Forum 2 07-01-2006 07:17 PM