DIY Home Improvement, Remodeling & Repair Forum > DIY Home Improvement > Plumbing Forum > Finned Baseboard and Slab Leak




Reply
 
LinkBack Thread Tools Search this Thread Display Modes
Old 01-08-2008, 10:11 AM  
tw40x81
Junior Member
 
Join Date: Jan 2008
Posts: 3
Default Finned Baseboard and Slab Leak

I've got a leak in the concrete slab where the copper tube is routed under a sliding door for my hydronic baseboard.

Can I route the tube over the door and though the drop ceiling, or would it be better to cut the concrete and replace the copper?



__________________
tw40x81 is offline  
 
Reply With Quote Quick reply to this message
Old 01-08-2008, 04:24 PM  
glennjanie
Senior Member
 
Join Date: Mar 2006
Posts: 2,990
Liked 2 Times on 2 Posts

Send a message via AIM to glennjanie
Default

Welcome TW:
If the installer didn't know to keep the copper tube seperate from the concrete it would be best to run it overhead. Concrete and copper just aren't compatible and the copper looses every time.
When you run the line into the drop ceiling, make one end higher by 1/4" and put in an automatic air vent in. That will now be the highest point of the system and it needs an air bleed to get the lines to run full and heat well.
Glenn



__________________
glennjanie is offline  
 
Reply With Quote Quick reply to this message
Old 01-09-2008, 05:31 AM  
inspectorD
Housebroken
HRT_MODERATOR.png
 
inspectorD's Avatar
 
Join Date: Dec 2005
Location: Litchfield, CT
Posts: 4,054
Liked 122 Times on 102 Posts
Likes Given: 286

Default Hmmmm

Glenn always knows just what to say.
And another point is ...if you have any more lines in the concrete, you might as well go ahead and change those out. The system will need to be drained anyway so now is the time.
Good luck.

__________________

Just My
Made in the

inspectorD is offline  
 
Reply With Quote Quick reply to this message
Old 01-10-2008, 09:12 AM  
tw40x81
Junior Member
 
Join Date: Jan 2008
Posts: 3
Default

Thank you, thank you, now I have a plan. Follow-up Question: Is there any way of neatly "trimming in" the copper that will run vertically up each side of the sliding door?

__________________
tw40x81 is offline  
 
Reply With Quote Quick reply to this message
Old 01-10-2008, 10:31 PM  
glennjanie
Senior Member
 
Join Date: Mar 2006
Posts: 2,990
Liked 2 Times on 2 Posts

Send a message via AIM to glennjanie
Default

Yes, you could use a 2 x 4 finish grade and rout out a channel in it for the pipe. You will probably be using 3/4" copper and the outside measurement of even the fittings is 1" while the tube is 7/8" od.
Some trim around the top and bottom could make it look like load-bearing posts.
Glenn



__________________
glennjanie is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On