I have a sewer smell coming from my toilet. I have had some rocking of the toilet so it might be the wax ring. If I remember, the flange was partially broken which caused the securing the toilet with the bolt a difficult thing to do. I would hate to take the toilet up if this is not the problem.

My other issue and possible cause is that the toilet is not vented properly. the venting ends in the basement. There is a cover on the pipe. When I remove the cover, I smell the odor. If I vent, will that take care of the problem?



__________________
cibula11 is offline  
 
Reply With Quote Quick reply to this message
Old 11-08-2007, 11:13 AM  
travelover
Senior Member
 
Join Date: Aug 2007
Posts: 693
Liked 2 Times on 2 Posts

Default

If it is not vented, it definitely should be, for several reasons, one of which is how well it flushes. Also if it is rocking, then the wax ring is not sealing, which will cause it to leak sewer gas.

Sorry to be the bearer of bad news, but you'll need to fix the flange, or the wax ring won't seal. if you take a picture of the broken flange, perhaps we can suggest a repair method.



__________________
travelover is offline  
 
Reply With Quote Quick reply to this message
Old 11-08-2007, 12:09 PM  
cibula11
Senior Member
 
Join Date: Dec 2006
Posts: 331
Default

I can't take a picture of it, but I remember exactly what the problem was. The place on the flange where the bolt attaches to is cracked. Other than one bolt being diffult to tighten, the flange was fine.

My floor is not extremely level so we did have to shim the toilet about 1/8". If I use a flange extender and one wax ring instead of a double ring ( the newer tile floor raised it too high just to use one ring), would that help? I also thought that the flange extender would solve the problem with the cracked flange.

__________________
cibula11 is offline  
 
Reply With Quote Quick reply to this message
Old 11-08-2007, 12:47 PM  
glennjanie
Senior Member
 
Join Date: Mar 2006
Posts: 2,990
Liked 2 Times on 2 Posts

Send a message via AIM to glennjanie
Default

Hello Cibula:
The toilet will never stay in place until you replace the flange or run bolts all the way through the floor. Shimming is good; takes all the rocking out of it. There is also a closed cell foam ring on the market now which remains resilient; whereas the wax ring seal is broken with one movement. After the toilet is set and shimmed like you want it, use silicone caulk to make a seal around the bowl. Most professionals do that now and it eliminates lots of call backs.
I'm suspecting the capped pipe in the basement is a clean-out. Make sure there is not a vent going through the roof. I can't imagine anyone installing a plumbing job without a vent.
Caution: The sewer gas you smell is also known as methane gas (same thing as natural gas) which is deadly. Be sure there is a vent somewhere.
Please let us know how it goes.
Glenn

__________________
glennjanie is offline  
 
Reply With Quote Quick reply to this message
Old 11-08-2007, 01:07 PM  
cibula11
Senior Member
 
Join Date: Dec 2006
Posts: 331
Default

2 questions:

1. Should I take the toilet off, repair flange (I was thinking of using a kit so that I have something to secure the toilet), add extender flange and then the closed cell foam that you refered to?

2. Honestly, there is no vent that exits the roof. One for the kitchen sink, but nothing else. I know that the sink and toilet are connected on the main waste vent. I can't go through the roof, but I could exit through the side of my house. Is that possible?

__________________
cibula11 is offline  
 
Reply With Quote Quick reply to this message
Old 11-08-2007, 04:07 PM  
glennjanie
Senior Member
 
Join Date: Mar 2006
Posts: 2,990
Liked 2 Times on 2 Posts

Send a message via AIM to glennjanie
Default

Hello Cibula:
Yes to number one.
Question #2. Yes you can go up the side of your house with 3" pipe (PVC or ABS) and through the overhang to 1' above the roof. If you can't go through the overhang, you may use 2 45* ells to off set and go around the overhang. I would want to paint the pipe to match the house upon completion. A 3" pipe can look a little out of place on the outside of the house.
Glenn

__________________
glennjanie is offline  
 
Reply With Quote Quick reply to this message
Old 11-08-2007, 06:33 PM  
travelover
Senior Member
 
Join Date: Aug 2007
Posts: 693
Liked 2 Times on 2 Posts

Default

Quote:
Originally Posted by glennjanie View Post
.......... A 3" pipe can look a little out of place on the outside of the house.
Glenn

Yea, it would look like England.


__________________
travelover is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
HELP!!! What's that smell??? GayleDu General Home Improvement Discussion 8 03-01-2013 10:32 AM
smell in island water dsjoiner Plumbing Forum 3 01-03-2009 03:23 PM
AC smell TaskBoy HVAC 2 09-08-2008 01:30 PM
Funky Bath Tub Smell! Please Help! dean General Home Improvement Discussion 4 05-01-2008 09:57 AM
Strange smell ! staticbob General Home Improvement Discussion 2 01-21-2007 11:19 AM