05-24-2009, 01:27 PM
|
|
|
Emperor Penguin
Join Date: Mar 2009
Location: Winnipeg, Manitoba
Posts: 1,846
Liked 1 Times on 1 Posts
|
Toilet rough-in
My understanding is that the standard toilet rough-in is 12 inches, and I understand that to mean that there should be 12 inches from the middle of the floor flange to the front face of the studs.
Is that correct?
My building has plaster walls, and I often find them to be over 3/4 inch thick, and I often find that the toilet floor flange is set too close to the wall anyhow.
Does anyone know if there are any commonly available toilets that are designed for a 10 inch rough-in, or that are designed for a 12 inch rough-in but leave plenty of room behind the tank?
I'm trying to solve this problem before I'm staring it in the face. I want to find a replacement toilet I can use if a toilet gets damaged and I have to replace it.
|
|
|
05-24-2009, 06:24 PM
|
|
|
Certified Lunatic
Join Date: Apr 2009
Location: Olde Tyme, Connecticut
Posts: 887
|
The rough in dimension is from the finished wall surface to the center of the closet flange.
|
|
|
05-24-2009, 09:02 PM
|
|
|
Emperor Penguin
Join Date: Mar 2009
Location: Winnipeg, Manitoba
Posts: 1,846
Liked 1 Times on 1 Posts
|
that's what I thought, but I had a plumber redo the toilet drain pipe under a basement suite, and he said it was from the studs, so I thought I was mistaken.
|
|
|
05-25-2009, 06:26 AM
|
|
|
Senior Member
Join Date: Sep 2006
Location: Lafe Arkansas, Arkansas
Posts: 166
|
12" to the finished wall is standard. You can purchase 10" rough toilets, but they are not usually an in-stock item. They can be ordered though.
__________________
if you have never made a mistake, you probably haven't done much.
|
|
|
05-25-2009, 12:00 PM
|
|
|
Senior Member
Join Date: Mar 2006
Posts: 2,998
Liked 1 Times on 1 Posts
|
There is also an 'offset' toilet flange that can make up for about 1 1/2" of mistake.
Glenn
|
|
|
05-25-2009, 03:12 PM
|
|
|
Emperor Penguin
Join Date: Mar 2009
Location: Winnipeg, Manitoba
Posts: 1,846
Liked 1 Times on 1 Posts
|
Thanks guys. I was aware of the 10 inch rough-in toilet and the offset floor flange.
I was more wondering if anyone knew of a 12 inch rough-in toilet that had plenty of room behind it that it could be used evenwhere the rough-in was only 11 or 10 1/2 inches instead of a full 12 inches of space.
|
|
|
05-26-2009, 05:57 AM
|
|
|
Senior Member
Join Date: Sep 2006
Location: Lafe Arkansas, Arkansas
Posts: 166
|
Since the rough-in measurement is designed to place the tank near or against the wall, finding one that consisently leaves thatmuchplay would be difficult. Sometimes you can get 1/4 to 1/2" in the floor and tank bolt holes.
__________________
if you have never made a mistake, you probably haven't done much.
|
|
|
05-30-2009, 05:30 PM
|
|
|
Certified Lunatic
Join Date: Apr 2009
Location: Olde Tyme, Connecticut
Posts: 887
|
Check the Toto Drake II out it is a 12" rough toilet that will fit all the way down to an 10 3/4" rough with a squeak fitting...
Check the specifications linked below they show a 1 1/4" gap between the tank and the wall. The Drake II is a great performer as well. !.28 GPF double Cyclone flush Technology, Sanagloss... What more could you want in a toilet?
Formerly called the Gwyneth and only a little higher priced than the regular Drake Probably the best deal to be had at Toto these days.
Toto Drake II Specifications
Toto Drake II Product Page
Toto Dealer Locator
|
|
|
05-30-2009, 05:55 PM
|
|
|
Emperor Penguin
Join Date: Mar 2009
Location: Winnipeg, Manitoba
Posts: 1,846
Liked 1 Times on 1 Posts
|
Thanks, Redwood, that was more what I was after; a 12 inch rough in toilet that allowed ample space behind it so that it would still fit even when you didn't have a full 12 inches of room.
I, for one, do not understand why a toilet tank should be tight against the wall. No one sitting on a toilet leans back into it the way you do on a couch or sofa. And, having the toilet tank tight to the wall only creates problems with condensation forming on the wall in that area and the resulting plaster damage.
I see absolutely no reason not to allow an inch or two of space behind a toilet tank.
|
|
|
05-30-2009, 06:26 PM
|
|
|
Certified Lunatic
Join Date: Apr 2009
Location: Olde Tyme, Connecticut
Posts: 887
|
Shop around...
Internet prices get as low as $321 USD...
Google Search for Drake II
|
|
|
| Thread Tools |
Search this Thread |
|
|
|
| Display Modes |
Linear Mode
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
|
|
|