DIY Home Improvement, Remodeling & Repair Forum > DIY Home Improvement > Plumbing Forum > water supply to toilet cuts out




Reply
 
LinkBack Thread Tools Search this Thread Display Modes
Old 12-04-2009, 11:43 PM  
Albear
Junior Member
 
Join Date: Dec 2009
Posts: 3
Default water supply to toilet cuts out

My wife turn off the supply line to the toilet and when I turned it back on, no water came on. I removed the flexible line at the stop value and when I turned the value on, water came out. I hooked up the line and the toilet started to fill but at half way the pipe in the wall thundered and no more water. I did the same thing again and it filled about a quarter of the way and then bang and it stopped again. I replaced fill tube assembly and that didn't help. The cold water to the sink and tub work fine. I did this a few more times with the same result. I am baffled!



__________________
Albear is offline  
 
Reply With Quote Quick reply to this message
Old 12-05-2009, 06:46 AM  
Raindem
Member
 
Join Date: Jul 2008
Location: Sonoita, AZ
Posts: 38
Likes Given: 1

Default

I'm just guessing but you might have some loose debris in your inlet valve. The banging you hear is the shudder of the pipe when the water flow is suddenly blocked by whatever is in there.



__________________
Raindem is offline  
 
Reply With Quote Quick reply to this message
Old 12-05-2009, 08:58 AM  
majakdragon
Senior Member
 
Join Date: Sep 2006
Location: Lafe Arkansas, Arkansas
Posts: 165
Default

I think you still had debris in the line when you changed the fill-valve. This is now blocking the flow. Disconnect the flex pipe again and run water for a minute. You may need to flush out the fill valve also.

__________________

if you have never made a mistake, you probably haven't done much.

majakdragon is offline  
 
Reply With Quote Quick reply to this message
Old 12-05-2009, 12:47 PM  
Albear
Junior Member
 
Join Date: Dec 2009
Posts: 3
Default

I removed the flexible hose and drained about 2 gallons of water and then it shut off again. I reattached the flex hose and closed the stop valve. After about 10 minutes I opened the stop valve and the toilet start to fill but it stopped again.

__________________
Albear is offline  
 
Reply With Quote Quick reply to this message
Old 12-05-2009, 02:01 PM  
Launchpad
Member
 
Launchpad's Avatar
 
Join Date: Nov 2009
Posts: 41
Default

I had a situation somewhat similiar to that with a work toilet. It would part way and shut off because of debris in the line. We kept a hammer beside the toilet and tapped on the lines to get it working again. Not a recomended solution, but it worked for a bunch of lazy redknecks....

__________________

[B][COLOR="Blue"]I was lying in bed, looking at the stars, and I wondered, where did my ceiling go?[/COLOR][/B]

Launchpad is offline  
 
Reply With Quote Quick reply to this message
Old 12-05-2009, 03:17 PM  
Redwood
Certified Lunatic
 
Redwood's Avatar
 
Join Date: Apr 2009
Location: Olde Tyme, Connecticut
Posts: 887
Default

Are you using a Watts FloodSafe supply line for your toilet?

__________________
Redwood is offline  
 
Reply With Quote Quick reply to this message
Old 12-05-2009, 03:30 PM  
Albear
Junior Member
 
Join Date: Dec 2009
Posts: 3
Default using watts floodsafe

I am using a Watts flood safe auto-shutoff connecter.

__________________
Albear is offline  
 
Reply With Quote Quick reply to this message
Old 12-05-2009, 06:50 PM  
Nestor_Kelebay
Emperor Penguin
 
Nestor_Kelebay's Avatar
 
Join Date: Mar 2009
Location: Winnipeg, Manitoba
Posts: 1,844
Liked 2 Times on 2 Posts

Default

OK, I'm gonna guess that Watts FloodSafe supply line connectors aren't at the very top of Redwood's list of "favourite things".

__________________
Nestor_Kelebay is offline  
 
Reply With Quote Quick reply to this message
Old 12-08-2009, 03:53 AM  
Superpack
Member
 
Join Date: Oct 2009
Posts: 98
Default

I always put pipe dope on the ferule before I install a new angle stop and especially if I am reusing the old ferule. Some of the new 1/4 turn stops don't touch the ferule when slipped onto the pipe so if that is what you have you need to tighten it enough to slide the ferule on the pipe to make contact with the new valve.

Regards,

__________________
Superpack is offline  
 
Reply With Quote Quick reply to this message
Old 12-17-2009, 09:23 PM  
Redwood
Certified Lunatic
 
Redwood's Avatar
 
Join Date: Apr 2009
Location: Olde Tyme, Connecticut
Posts: 887
Default

Quote:
Originally Posted by Nestor_Kelebay View Post
OK, I'm gonna guess that Watts FloodSafe supply line connectors aren't at the very top of Redwood's list of "favourite things".
How right you are Nestor they are well known for false trips.

The method he described of shutting off the water and loosening the compression fitting on the angle stop valve then retightening it and turning the water back on is how they are reset.

Unfortunately they are also becoming well known for failing at the connection between the compression connection and the flood safe valve which floods the home.

I would get rid of them ASAP

Unfortunately they are a marketing gimmick gone wrong that serves no useful purpose.
Can you imagine a need for a valve that offers protection from a no-burst hose bursting?
Sounds redundant to me...


__________________
Redwood is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Fitting copper water supply pieces together dogpal Plumbing Forum 9 10-14-2009 03:48 PM
Framing/Insulating around water supply pipe HeyPally Framing and Foundation 8 01-27-2009 08:26 AM
Erratic hot water supply with Takaji tankless B.Thomas Plumbing Forum 2 05-24-2008 08:58 PM
bath sink hot water supply line leak jmjoseph General Home Improvement Discussion 2 04-23-2007 09:21 AM
Water Supply Line and Building Code Carcosa Plumbing Forum 3 01-20-2007 10:18 AM