Default Colonial Gambrel Roof ventilation questions

Hi All,

I just purchased an old Colonial Gambrel house (1927) and the roof needs to be replaced. Right now there is Zero ventilation in the roof, its completely sealed. I talked to the roofer who suggested that I put in a ridge vent and a roof fan, but due to the style of the house I cant put in soffet vents.

Will the ridge vent and roof fan be sufficient? Since I am doing the roof over now I would prefer to do as much as I can to make it right.

Any other suggestions would be greatly appreciated.

Thanks



__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 08-09-2012, 01:28 PM  
nealtw
Senior Member
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 7,741
Liked 541 Times on 490 Posts
Likes Given: 1000

Default

Welcome to the site. Below is a link for vented drip edge which would only work if you have air space between the insulation and the roof sheeting all the way to the ridge.

http://www.google.ca/search?q=vented+drip+edge&hl=en&prmd=imvns&tbm=isc h&tbo=u&source=univ&sa=X&ei=vg0kUIPvEeWOiALk24HoBA &sqi=2&ved=0CEwQsAQ&biw=1016&bih=523



__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Old 08-09-2012, 03:57 PM  
oldognewtrick
Moderator
HRT_MODERATOR.png
 
oldognewtrick's Avatar
 
Join Date: Jul 2009
Location: Nashville, TN
Posts: 3,777
Liked 277 Times on 232 Posts
Likes Given: 89

Default

You can use a vented drip edge at the transition of the gambrel to the upper roof and ridge vent at the top. NEVER use ridge vent in combination with a power vent. And to House Repair Talk!

__________________
oldognewtrick is offline  
 
Reply With Quote Quick reply to this message
Old 08-10-2012, 07:02 AM  
joecaption
Senior Member
 
Join Date: Jan 2011
Location: Hartfield VA, VA
Posts: 1,359
Liked 36 Times on 31 Posts
Likes Given: 2

Default

Posting a picture of your home would sure help.

The reason Old Dog said that is a power vent will do nothing but suck air in through the ridge vent since that's it's closest source of air.
Not going to help with making the attic cooler, or getting rid of the moist air that's trapped there.

__________________
joecaption is offline  
 
Reply With Quote Quick reply to this message
Old 08-10-2012, 07:38 PM  
drewdin
Junior Member
 
Join Date: Aug 2012
Posts: 373
Liked 22 Times on 20 Posts
Likes Given: 73

Default

Hey guys, thanks for the quick responses! I'm a first time home buyer and learning about houses as I go.

I took some pictures of the house today, how do I know if there is air space between the insulation and the roof sheeting? I do know that there is horsehair plaster throughout the house so its not easy to open anything and take a peek. How can I check for the air space, any suggestions? Thanks again

https://www.dropbox.com/s/4udovl76ups6xmd/2012-08-10%2015.38.13.jpg

__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 08-10-2012, 08:27 PM  
drewdin
Junior Member
 
Join Date: Aug 2012
Posts: 373
Liked 22 Times on 20 Posts
Likes Given: 73

Default

I checked out those smart vents, they look pretty awesome. How do I know how many I need?

__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 08-11-2012, 07:32 AM  
joecaption
Senior Member
 
Join Date: Jan 2011
Location: Hartfield VA, VA
Posts: 1,359
Liked 36 Times on 31 Posts
Likes Given: 2

Default

Measure the lenght of the roof and devide by 4.
There not suppost to be installed all the way to the ends of the roof so round down when coming up with a number.
Your also going to need some 3" roofing nails, some vents come with the nails but check before leaving the store.
Your also going to need some ridge caps, one bundle of caps will do about 23 liner ft. of roof. I suggest not using cut up 3 tab shingles there to thin and tend to crack over time. Buy real hip and ridge caps. Yes there more expencive, but worth it.

__________________
joecaption is offline  
 
Reply With Quote Quick reply to this message
Old 08-22-2012, 08:20 PM  
drewdin
Junior Member
 
Join Date: Aug 2012
Posts: 373
Liked 22 Times on 20 Posts
Likes Given: 73

Default

thanks guys, i called DCI and found a local roofer who is going to install some smart vents. Thanks for all the help



__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Venting and Insulation of a Gambrel Roof smuttydog Insulation and Radiant Barriers 4 11-25-2010 02:51 PM
Roof Ventilation sdouglas Roofing and Siding 1 06-23-2009 12:15 PM
Help with ventilation of Gambrel Roof weng19 Roofing and Siding 5 03-04-2008 06:40 PM
Adding Attic/Roof Ventilation? 1parkpointer Roofing and Siding 4 12-07-2007 12:08 PM
Shed roof - Gambrel dakuda Roofing and Siding 5 06-03-2007 04:24 PM