Default Hole in sheathing under vinyl siding at outside outlet

I noticed that an electrical outlet on the outside wall of my house is well sealed to the siding with caulk, but the outlet (with vinyl siding) float and can be push/pulled 1/2" each way. I was prepared to put the retaining strips in the hole beside the outlet box and bend over the tabs to prevent the box from being pulled out. After removing the outlet, I saw that the metal box is screwed to the siding, and nothing else. I removed the box, and found that the particle board sheathing has been bashed in rather than cut. The crater is about 6" in diameter. There was a vacated wasp nest in there, and the insulation is compressed against the drywall also. I am guessing the builder forgot to install this outlet and retrofitted it with a hammer. All the other outside outlets feel secure, so for now I assume they were installed correctly.

I want to repair this, and get the outlet secured to something solid. I also want to get a better vapor and insulation seal at this site. It is a great source of air infiltration. I assume I should open the wall from the inside and put a piece of plywood over the sheathing hole larger than the hole and fill in the missing particle board with a custom piece. Then I will cut a rectangle for the outlet box and screw the box to this reinforced sheathing. Is this necessary or advisable? I think I can do this without removing any siding, because I am concerned about cracking it if I remove any. It will probably need a 10x10" wallboard hole, I think, and that is not very appealing, either. Is this what I should do?



__________________
edlank is offline  
 
Reply With Quote Quick reply to this message
Old 03-09-2009, 09:00 PM  
glennjanie
Senior Member
 
Join Date: Mar 2006
Posts: 2,990
Liked 2 Times on 2 Posts

Send a message via AIM to glennjanie
Default

Welcome EdLank:
I have 4 outdoor outlets that were pulled out of the original wall and moved to match the center of the vinyl sheet for appearance.
It may take both hands to plug in or unplug a cord but I don't think it is a problem you need to deal with. Does the siding not have the fan-fold insulation behind it? That would take care of the air infiltration.
Glenn



__________________
glennjanie is offline  
 
Reply With Quote Quick reply to this message
Old 03-10-2009, 07:32 AM  
jdougn
Senior Member
 
Join Date: Aug 2006
Posts: 132
Liked 1 Times on 1 Posts

Default

Welcome Edlank,

Glenn gives good advice. I'd be inclined to just let it ride too. You may want to use some canned expanding foam, Great Stuff is one brand, and foam the hole inside the wall. Expanding foam would keep out air, insects, and moisture. The foam will stick to most anything it touches so protect the siding and your clothes.
hth, Doug

__________________
jdougn is offline  
 
Reply With Quote Quick reply to this message
Old 03-11-2009, 12:55 PM  
handyguys
Senior Member
 
handyguys's Avatar
 
Join Date: Feb 2008
Location: USA
Posts: 815
Liked 1 Times on 1 Posts

Send a message via Skype™ to handyguys
Default

Additionally - That expanding foam, if you let it fill behind the jbox, will help hold it in place.

What an elegant, all be it a little half assed, solution. Sure, the proper thing would be to pull off all the siding, replace the damaged sheeting and put everything back.

One trip to the store, a $6 can of foam and 5 minutes and you are done! Great suggestion.

__________________

The Handyguys Podcast [url]http://www.handyguyspodcast.com[/url]

handyguys is offline  
 
Reply With Quote Quick reply to this message
Old 07-10-2011, 07:48 PM  
edlank
Member
 
Join Date: Apr 2008
Location: Hershey, PA
Posts: 53
Default

I could not settle for the foam solution alone. The first picture is what I found after taking off one piece of siding. It shows how well someone's hammer works. The sheathing had vapor barrier on the inside (?) but a gaping hole at this outlet. A wasp had built a nest within the wall.

With a piece of 1 by 8 behind the hole, I filled in with wood pieces and build it up and sealed it flush. This should decrease the air infiltration into the wall.

outsideoutlethole.jpg   outsideoutletfixed.jpg  
__________________
edlank is offline  
 
Reply With Quote Quick reply to this message
Old 08-02-2011, 03:08 PM  
BrianKiernan
Member
 
Join Date: Aug 2010
Posts: 42
Default

Nice repair

What do you call an electricians keyhole saw?

A hammer

__________________

Good Luck,
Brian
[URL="http://www.install-crown-molding.com"][COLOR="Blue"]http://www.install-crown-molding.com[/COLOR][/URL]

BrianKiernan is offline  
 
Reply With Quote Quick reply to this message
Old 08-17-2011, 09:05 AM  
edlank
Member
 
Join Date: Apr 2008
Location: Hershey, PA
Posts: 53
Default

For these electricians, that is right. A few seconds of cutting would have saved me hours, and avoided the horrible air infiltration this house had before I got back to fixing this.

Since then, I have worked on other outlets that were secured to the OSB, but were in the middle of very oversized holes.

What is the usual way of securing electrical devices to a structure with vinyl siding to avoid deforming the siding as the device is tightened? I used small wood strips under the siding at the box to keep the siding at its natural standoff height.

Is the vapor barrier on the inside of the OSB ever appropriate?

__________________
edlank is offline  
 
Reply With Quote Quick reply to this message
Old 08-17-2011, 10:40 AM  
TxBuilder
HRT_LIFETIMESUPPORTER.png
 
TxBuilder's Avatar
 
Join Date: Feb 2005
Posts: 1,677
Liked 5 Times on 5 Posts
Likes Given: 4

Default

Looks much better. Thats what I was going to suggest you do.

__________________
TxBuilder is offline  
 
Reply With Quote Quick reply to this message
Old 08-17-2011, 01:03 PM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 9,904
Liked 814 Times on 727 Posts
Likes Given: 1405

Default

I would bet it the the siding people that didn't want to take the time to put in the box extender to bring it out to fit their plug cover.



__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
How to flash/mount new window install with only T1-11 siding,..no sheathing! Dr_Jim Windows and Doors 16 08-20-2012 09:41 PM
cutting a hole for an electrical outlet daniel2229 General Home Improvement Discussion 9 07-22-2008 04:24 PM
Stains on vinyl siding tdoyon Roofing and Siding 3 01-29-2008 04:09 PM
can i paint vinyl siding elementx440 Roofing and Siding 1 01-31-2007 07:11 PM
painting vinyl siding ruby Roofing and Siding 3 03-29-2006 10:23 PM