Default Opinions on vented drip edge (inhaler style)?

(apologies if this shows up twice; using a new app for this :-)

My house (in southeastern Tennessee) was built in the late 1930s, and the roof has no overhang (no soffits). I'm having it re-roofed (stripping off the multiple layers of shingles down to the planking -- from what I can tell, there looks to be 3 layers of shingles, and the lowest level looks like ancient shingles from the 1960s, so yes, definitely in need of re-roofing). Also having gutters and several of the fascia boards replaced, too. The existing venting in my unfinished open attic space consists of 2 "not large" gable vents (one at each end of house). There's never been soffit venting, since there are no soffits.

As part of re-shingling, the plan is to add ridgeline vents. However, since the only intake would be from the gable vents, it doesn't seem to me that there would be sufficient airflow for decent ventilation. I've found information on vented drip edges (which add a lower source of intake air by retrofitting the intersection of the roof and the exterior wall), but I'm troubled by products like the Air Vent that have vents positioned basically over the gutter (and if the gutters are blocked or covered with snow/ice, might allow water to enter, in some instances).

I've discovered another approach, however, with products like the Ever-Flo Inhaler Vents. (Kudos on having a company name and product name that leads to Google results that mostly deal with respiratory ailments.) Here's a link: http://www.everflovent.com/pro_inhaler.html

This Inhaler vent basically goes BEHIND the gutter to feed air into the attic (the air actually enters underneath or below the gutter, as opposed to other vented drip edge designs where the air enters above the gutter). Use of gutter is optional in its use.

Seems like this would solve my ventilation problem. Anyone have experience with this approach or product?



__________________
philipluckey is offline  
 
Reply With Quote Quick reply to this message
Old 02-05-2012, 09:30 PM  
nealtw
Senior Member
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 7,729
Liked 541 Times on 490 Posts
Likes Given: 998

Default

I think that is the best answer, When you have that done you should also close the gable vents.



__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Old 02-06-2012, 06:35 AM  
oldognewtrick
Moderator
HRT_MODERATOR.png
 
oldognewtrick's Avatar
 
Join Date: Jul 2009
Location: Nashville, TN
Posts: 3,760
Liked 276 Times on 231 Posts
Likes Given: 89

Default

Also, make sure that the insulation in the attic does not restrict the air flow at the lower edge where the roof meets the sofit. If you have a built out attic the insulation in between the rafter bays will restrict your ability to have any air movement, unless they installed baffles between the insulation and roof deck.

__________________
oldognewtrick is offline  
 
Reply With Quote Quick reply to this message
Old 02-16-2012, 10:32 AM  
ZnCuSnRoofer
Junior Member
 
Join Date: Oct 2010
Location: Alexandria, VA, VA
Posts: 3
Default

Your house is perfect for a product I've been using for years with houses like yours that have no soffit.

Look here: http://www.dciproducts.com/html/smartvent.htm

or use this product if replacement gutters are in your future, when using FaciaFlow the existing gutters will need to be removed

http://www.gaf.com/Roofing/Residential/Products/Roof-Vents/Cobra-FasciaFlow-Vent

or this one: this product is a little newer but comes from a good company:

http://www.airvent.com/professional/products/intake-theedge.shtml


You absolutely need waterproof underlayment like Grace or GAF Weather watch at the eaves, dormers and valleys; it should extend at least 24" past the warm wall but further isn't really necessary.

The first and third linked products are a little more amenable to having insulation stuffed into the eave because they typically vent above the attic floor.



Good luck,
Tom
www.lyonscontracting.com

__________________
ZnCuSnRoofer is offline  
 
Reply With Quote Quick reply to this message
Old 03-07-2012, 11:53 AM  
philipluckey
Junior Member
 
philipluckey's Avatar
 
Join Date: Feb 2012
Posts: 3
Default

Well, i had my roof replaced last week, and wanted to share an update. I introduced the Cobra FasciaFlow boards to my roofing contractor -- he'd never seen such a thing. He checked with the local roofing supply company, and they didn't have any in stock. It could be ordered, but they order by the pallet (at $9,000 per pallet). Too expensive per piece, anyway. So we went with a vented drip edge instead (made of sheet metal). It's all done now, looks much better. In addition to removing all old shingles and installing new 3-tab Tamko 25-yr shingles, I had them build a roof over my front porch stoop and replace old gutters with new 6" gutters (with screens). All completed now; now I won't dread rainstorms!

Here's a short video summary of the new roof on my home:

__________________
philipluckey is offline  
 
Reply With Quote Quick reply to this message
Old 03-07-2012, 12:24 PM  
nealtw
Senior Member
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 7,729
Liked 541 Times on 490 Posts
Likes Given: 998

Default

I got a little dizzy watching the video, but it looks good.



__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Opinions on vented drip edge (inhaler style)? philipluckey Roofing and Siding 0 02-04-2012 10:18 AM
Is Drip edge needed in this situation? Dimeron Roofing and Siding 4 05-05-2009 02:49 PM
Drip Edge/Flashing Rchaffin Roofing and Siding 6 04-22-2009 07:14 PM
Do Nat. Gas Dryers need to be vented outside? phreaq General Appliance Discussion 7 02-14-2008 12:56 PM
Flashing/drip edge on roof - questions & advice Westy Roofing and Siding 4 09-24-2007 07:37 PM