Old 08-15-2011, 02:50 PM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 10,230
Liked 841 Times on 751 Posts
Likes Given: 1456

Default WhirlyBird Turbine Vents

Has anyone seen a study that shows these move more air than any other vent of the same size



__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Old 08-15-2011, 03:52 PM  
oldognewtrick
Moderator
HRT_MODERATOR.png
 
oldognewtrick's Avatar
 
Join Date: Jul 2009
Location: Nashville, TN
Posts: 5,403
Liked 458 Times on 381 Posts
Likes Given: 144

Default

Check out the MFG's websites Lomanco, Inc., Ventilation, Ventilators, Vents, Whirlybirds, Intake Vents, Exhaust Vents, Foundation Vents, Attic ventilation or Air Vent



__________________
oldognewtrick is offline  
 
Reply With Quote Quick reply to this message
Old 08-15-2011, 04:11 PM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 10,230
Liked 841 Times on 751 Posts
Likes Given: 1456

Default

I have checked it out, they don't make any claims like you would expect, if they really do better than flat vents.

__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Old 08-16-2011, 11:25 AM  
paul52446m
Senior Member
 
Join Date: Oct 2010
Location: Houghton Lake, Mi.
Posts: 435
Liked 1 Times on 1 Posts

Default

Quote:
Originally Posted by nealtw View Post
I have checked it out, they don't make any claims like you would expect, if they really do better than flat vents.
I have one 14"rd. wind vent in a attic that is 800 Sq.' At a 7 mi. an hr. wind, it will move 4 times more than the 12" sq vent that was there before. This was
tested with a CFM tester that i use for balancing commercial kitchen in restaurants. Paul
__________________
paul52446m is offline  
 
Reply With Quote Quick reply to this message
Old 08-16-2011, 02:13 PM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 10,230
Liked 841 Times on 751 Posts
Likes Given: 1456

Default

Wind blowing over an open hole will vacume the air, what happens when it is stopped and I would like to know how that would compare on a day when there is no wind because that what really counts.

__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Old 08-16-2011, 03:50 PM  
paul52446m
Senior Member
 
Join Date: Oct 2010
Location: Houghton Lake, Mi.
Posts: 435
Liked 1 Times on 1 Posts

Default

Your right the wind moving over a hole can pull a vacuum, but the same wind turning the wind vane moves a lot more air. and on a no wind day most roof vents are 6 or 8', mine is 14" and because its a flat roof i put it two foot in the air. This creates more chimney
action and moves more air. also it does not get under the snow and stop working like flat vents. I really like the wind vents

__________________
paul52446m is offline  
 
Reply With Quote Quick reply to this message
Old 08-16-2011, 06:17 PM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 10,230
Liked 841 Times on 751 Posts
Likes Given: 1456

Default

I'm just trying to settle an arguement for a couple of friends, everyone as an opinions and no one has proof. Still looking for that study or text book or something.
Thanks Neal



__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Can I replace the Whirlybird Turbine Vent on the Roof with something else? Cinderella Roofing and Siding 10 08-17-2011 08:47 PM
Switch from floor vents in slab to ceiling vents in attic? cubfan23 HVAC 1 07-21-2009 07:01 AM
Whirlybird to extract above ceiling in winter and bathroom in summer IAH Roofing and Siding 2 02-26-2009 10:56 AM
Roof venting with whirlybird? or another option? G Dot Roofing and Siding 11 12-11-2008 04:27 PM
Need help installing whirlybird please HeadOn Roofing and Siding 2 02-19-2007 12:28 AM