OIL is costing me an arm and a leg, they have these heat loans where there is no interest for 7 years. I am being pushed towards a 95% efficient boiler and an indirect water heater, my plumber told me that since my house is from 1927, there wis no way i could get that efficiency without going crazy and sealing the house, etc... but since the house is so old its not meant to function that way.

He is telling me to go with an 85% to 90% efficiency and a regular water heater.

I wanted to get everyones suggestions on efficiency and what is realistic vs what is worth the money. I am thinking that half of what the plumber is saying is true and the other half is he is old school.

I am just starting my research and any suggestions would be greatly appreciated.



__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 02-03-2014, 12:10 AM  
nealtw
Senior Member
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 8,948
Liked 679 Times on 608 Posts
Likes Given: 1201

Default

That sounds like two different dicussions. the house is the house. Your problem is, the cost of the better system compared to the cost of the fuel saved. If the house loses more heat then you will be using more fuel, I think that would point you to the system that uses less fuel.



__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Old 02-03-2014, 05:21 AM  
bud16415
Fixer Upper
 
bud16415's Avatar
 
Join Date: Feb 2013
Location: Erie Pa, Pa
Posts: 935
Liked 268 Times on 214 Posts
Likes Given: 95

Default

I agree with Neil the efficiency of your heat source is a separate thing than the efficiency of your house. Basically the heat source efficiency is a measure of the fuel burned and the heat that burning gives off and it’s the ratio between what goes into the house and whet goes up the chimney. The old systems needed to use some of the heat to get the waste products out of the house. It’s easy enough if the decision is between 90 and 95 % to take a look at what 5% of your fuel cost is and try and figure out how many years it will take to get a payback on the savings. It has been my experience that the higher efficiency units require more expensive or more frequent repairs. That may no longer true though some of the heating guys may have facts on that.

Many times the offset in heating cost can be seen thru things like insulation new doors and windows in an old home. So strictly speaking given X amount of money to spend you could get more bang for your buck doing those things and keeping a lesser efficient heat source. I think that’s what your heating contractor might have been alluding to. Sure if money is no object you would do everything.

An old timer once told me pertaining to small efficient cars and the cost of keeping them on the road, he said “If you wants all that economy you are going to have to pay for it!”

__________________
bud16415 is offline  
 
Reply With Quote Quick reply to this message
Old 02-03-2014, 10:51 AM  
drewdin
Junior Member
 
Join Date: Aug 2012
Posts: 389
Liked 23 Times on 21 Posts
Likes Given: 77

Default

Thanks for the insight, the plumber was pushing me away from the 95% indirect options while the heat loan place was pushing me towards it. Money is an issue, if i could get more from my oil I would keep it. I guess that leads me to insulation more in the attic, the exterior walls on the second floor and the crawl spaces to try get get more for my money.

I'll keep you posted on what i do

__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 02-03-2014, 11:24 AM  
nealtw
Senior Member
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 8,948
Liked 679 Times on 608 Posts
Likes Given: 1201

Default

With out knowing the numbers or doing the math I would lean toward the more efficient system. Changing the house to high efficiency is another problem.

__________________
nealtw is offline  
 
Reply With Quote Quick reply to this message
Old 02-03-2014, 11:58 AM  
bud16415
Fixer Upper
 
bud16415's Avatar
 
Join Date: Feb 2013
Location: Erie Pa, Pa
Posts: 935
Liked 268 Times on 214 Posts
Likes Given: 95

Default

The thing with making improvements to the house is they keep working forever once you spend the money. It’s really two different problems with the common denominator of money. Do you keep the heat you have in the house and use it longer or do you let it go but figure out a cheaper way to get the heat. A lot of these old houses were made the way they were because energy was cheap in 1927 or whenever. Most likely they heated with coal back then and a truck would dump a load into the basement. I know several people around here that heat with wood and don’t really care how much they burn because they have an endless supply. While I know another guy that built a super insulated underground house and a couple light bulbs and the people in it keep it heated.
My first house I looked into getting a gas well put in 30 years ago and it would have cost me $10,000 I remember thinking I could pay my gas bill with the interest off the 10k forever, or at least the payback seemed too far out to make the investment worthwhile. After about 20 years I wished I had put in the well.

Most of the time a mixed approach is best starting with the low hanging fruit. I guess there would be a way with math to figure out where you are at now knowing the sq ft and how much energy you use based around a monthly average temp. then you could get a feel for what way to go to get the biggest bang for your buck.

__________________
bud16415 is offline  
 
Reply With Quote Quick reply to this message
Old 02-03-2014, 07:51 PM  
BridgeMan
Senior Member
 
BridgeMan's Avatar
 
Join Date: Aug 2011
Location: Cottage Grove, Oregon
Posts: 731
Liked 66 Times on 60 Posts

Default

I was told by a reputable HVAC guy (when shopping for a new FA unit for a house in NM) that he wouldn't go with a 95% efficient gas furnace because they consistently had high failure frequencies, and were sometimes too complex for an average service tech to efficiently work on. He also said that repair parts were not only more expensive and less reliable than the parts used in less-efficient furnaces, but that they also weren't common enough to be stocked by local wholesalers, which often meant waiting up to a week longer (sometimes in bitterly cold weather) for a needed part to come in.

This was more than 20 years ago, so maybe things have changed regarding high-efficiency furnace reliability and their parts performance/availability.

__________________
BridgeMan is offline  
Wuzzat? Likes This 
Reply With Quote Quick reply to this message
Old 02-04-2014, 06:06 AM  
drewdin
Junior Member
 
Join Date: Aug 2012
Posts: 389
Liked 23 Times on 21 Posts
Likes Given: 77

Default

@BridgeMan, the exact words spoken by my plumber. I was up in the attic yesterday, there is barely any insulation and spots with none. Im going to start by getting that to an R38 and see how much oil i start saving.

__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 02-04-2014, 10:09 AM  
buffalo
Member
 
Join Date: Nov 2013
Posts: 56
Liked 3 Times on 3 Posts
Likes Given: 42

Default

My small contribution to the site , after driving Neal crazy with questions.

Every unit is sized by btus per hr , which is factored by the size of your house and insulation. For easy numbers lets say your bringing in 100,000 btus of natural gas. An 80% efficient furnace will only supply you with 80,000 btus as usable heat. The rest is out the chimney. A 95% efficient will supply 95,000 btu of heat.

I personally don't see many condensing high efficiency boilers going in around here. Boilers are much more expensive than forced air furnaces. What the price differance is between efficiency models I'm not sure , but I'd guess its sufficient. If your installer is afraid of them its probabaly because he didn't know much about them , and at that point I wouldn't want him to put it in . In my area , although plumbing outfits do install heating equipment , typically you want a heating contractor.

I'm in the same boat right now. I have an oil boiler and poor insulation. I believe oil is approximately 4x the cost of natural gas. It's a big reason why truck fleets who drive locally are converting their trucks to run on natural gas right now. Heating oil is basically diesel fuel. The conversions are big money , but thier paid off in a matters of years.

Back on subject , I have installed on demand boiler/domestic water units . I put one in my old house and my bill was cut in half. The boiler I replaced was pretty ruff. I will have natural gas tapped by next heating season. My plan is a forced air furnace but that would be expensive for someone hiring that out.

Before you decide look into rebates from the utility , and write offs from the government for installing high efficiency units.

__________________
buffalo is offline  
drewdin Likes This 
Reply With Quote Quick reply to this message
Old 02-08-2014, 08:44 AM  
Wuzzat?
Senior Member
 
Wuzzat?'s Avatar
 
Join Date: Jan 2010
Posts: 2,186
Liked 140 Times on 127 Posts
Likes Given: 80

Default

You'll also need to know this
http://www.degreedays.net/
for your location.



__________________
Wuzzat? is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Sizing water softener for best efficiency gembob Water Softener and Heater 20 12-09-2012 10:34 PM
Conversion from Direct to Indirect DHW heating...better pressure? broadbill HVAC 1 03-08-2011 10:13 AM
Fiberglass from attic pushed into house through light fixtures jaws51 General Home Improvement Discussion 2 07-14-2009 09:31 AM
Indirect H2O Heater: Water too hot! Porschepunk Plumbing Forum 4 10-15-2008 03:29 PM
Relative efficiency of hydronic baseboard? WestBentley HVAC 0 04-09-2007 12:01 PM