Quote:
Originally Posted by Wuzzat?
I guess that is technically a case where the solder did not "wet" the joint.

How long did that joint hold up against the 40 to 80 PSI water pressure, water hammer, chemical attack by what's in the water, etc., etc.?
Is the house on well water?
Did you open the joint by twisting?
I didn't have to swet off 2 of the joints, I twisted them off with channel locks by braking the crappy solder that was caked on. Those joists wasn't leaking which is amazing.

It was a apartment building on well water.

I wanted to install the new shower body by solder but landloard insisted I use pex line and adapters.

The hold bathroom was done completely wrong from tile to plumbing.


__________________
isola96 is offline  
 
Reply With Quote Quick reply to this message
Old 09-27-2012, 12:33 PM  
Wuzzat?
Senior Member
 
Wuzzat?'s Avatar
 
Join Date: Jan 2010
Posts: 1,851
Liked 95 Times on 86 Posts
Likes Given: 56

Default

Quote:
Originally Posted by isola96 View Post
I didn't have to swet off 2 of the joints, I twisted them off with channel locks by braking the crappy solder that was caked on. Those joists wasn't leaking which is amazing.

It was a apartment building on well water.

I wanted to install the new shower body by solder but landloard insisted I use pex line and adapters.

The hold bathroom was done completely wrong from tile to plumbing.
If those bad joints were seeping water at first, maybe small particles in the water clogged the leaks over time.
The well water pressure may only go up to 40 PSI and supposedly less than 20 PSI is a health hazard.

I don't get the impression that electricians check their work by putting heavy loads on the wiring and maybe nobody checks their plumbing work by putting 80 PSI on the lines. They'd need a booster pump.

http://www.google.com/search?client=safari&rls=en&q=%22class+action%22+pex+reliability&ie=UTF-8&oe=UTF-8


__________________

Last edited by Wuzzat?; 09-27-2012 at 12:38 PM.
Wuzzat? is offline  
 
Reply With Quote Quick reply to this message
Old 09-28-2012, 10:33 AM  
isola96
Senior Member
 
isola96's Avatar
 
Join Date: Oct 2011
Location: Lagrangeville, New York
Posts: 437
Liked 6 Times on 6 Posts

Default

Name:  image-976590006.jpg
Views: 27
Size:  30.2 KB

I'm not going to open another thread to continue my rant but what on earth?!? It's just so senseless to put shut offs here. Really come on lol
__________________
isola96 is offline  
 
Reply With Quote Quick reply to this message
Old 09-28-2012, 11:08 AM  
Wuzzat?
Senior Member
 
Wuzzat?'s Avatar
 
Join Date: Jan 2010
Posts: 1,851
Liked 95 Times on 86 Posts
Likes Given: 56

Default

Quote:
Originally Posted by isola96 View Post
Attachment 4324

I'm not going to open another thread to continue my rant but what on earth?!? It's just so senseless to put shut offs here. Really come on lol
I guess the guy was impulsive and did the first thing that popped into his head. He was "living in the moment."

So now to remove the faucet you at least have to remove the shutoff handle.

I prefer ball valve stops because you can tell if they're closed by just looking.
__________________
Wuzzat? is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On