Default Air Handler in the attic Question

There coming monday to install an Air handler in the attic of my house, right now there is no insulation up there.

I know once its installed, there will never be any insulation under it so I plan on buying some along with a sheet of wood and making a platform for it.

Does anyone have any other recommendations? How much should I put there? Should I even do it? Thanks



__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 04-12-2013, 09:13 AM  
nealtw
Contractor
 
Join Date: Nov 2010
Location: vancouver, b.c.
Posts: 9,704
Liked 790 Times on 705 Posts
Likes Given: 1353

Default

A buddy of mine has that, they put it right on the ceiling joists and then put in loose insulation all around it. The insulation gets into the overflow trey and plugs the pipe. It has to be serviced and they have no catwalk to walk on and nowhere to stand when servicing and when they come down thru the closet they bring insulation with them, so they they have to drap plastic over the clothes first.
So I would say yes.



__________________
nealtw is offline  
drewdin Likes This 
Reply With Quote Quick reply to this message
Old 04-12-2013, 10:19 AM  
bud16415
Fixer Upper
 
bud16415's Avatar
 
Join Date: Feb 2013
Location: Erie Pa, Pa
Posts: 1,112
Liked 319 Times on 253 Posts
Likes Given: 105

Default

My suggestion would be talking to them first. That is the guys installing the air handler. They may have a system of mounting it already in the works or then again they might not and welcome your idea.

I think nealtw’s suggestions are all great and a catwalk is very nice to have above your insulation. Depending on how it is framed and where you live the framing might be less than the thickness of insulation you will want and things will have to be framed up.

It’s a good idea just make sure you think it thru till the end first.

__________________
bud16415 is offline  
nealtw Likes This 
Reply With Quote Quick reply to this message
Old 04-12-2013, 04:56 PM  
CallMeVilla
Contractor
 
CallMeVilla's Avatar
 
Join Date: Feb 2010
Location: San Diego
Posts: 1,245
Liked 379 Times on 297 Posts
Likes Given: 153

Default

Rigid insulation is an option below and around the handler in the joist bay. I would certainly provide a plywood platform and plywood from the access to the handler for servicing.

Just got out of an attic electrical install where there was one piece of plywood to slide around so I could work on electrical. It sucked.

bad_electrical_work_in_the_attic.jpg  
__________________

Last edited by CallMeVilla; 04-12-2013 at 04:58 PM.
CallMeVilla is offline  
 
Reply With Quote Quick reply to this message
Old 04-12-2013, 05:05 PM  
kok328
Supporting Member
HRT_SUPPORTER.png
 
Join Date: Nov 2007
Location: Grand Blanc, MI
Posts: 2,179
Liked 104 Times on 91 Posts
Likes Given: 61

Default

The contractor should install large drip pan under the unit just in case the condensate pump fails.
Rolled insulation and plywood should be installed for servicing unless you want somebody coming through your ceiling.
CallmeVilla,FYI - that J-box looks overloaded and will need a cover plate installed.

__________________
kok328 is offline  
drewdin Likes This 
Reply With Quote Quick reply to this message
Old 04-12-2013, 05:11 PM  
CallMeVilla
Contractor
 
CallMeVilla's Avatar
 
Join Date: Feb 2010
Location: San Diego
Posts: 1,245
Liked 379 Times on 297 Posts
Likes Given: 153

Default

Hey KOK ... the photo is a real life mess ... the attic I am working on had three more nests like that which were WORSE that I had to clean up. Didn't take a photo yet of the recessed lights with the ROMEX insulation outside the light box and the wires hanging on the sharp edges of the holes without connectors.

Oh, did I mention the back-to-back GFCIs that were in adjoining walls??

__________________
CallMeVilla is offline  
inspectorD Likes This 
Reply With Quote Quick reply to this message
Old 04-13-2013, 10:09 AM  
drewdin
Junior Member
 
Join Date: Aug 2012
Posts: 391
Liked 25 Times on 22 Posts
Likes Given: 78

Default

Thanks Guys, I called the contractor and he said that he plans on hanging the AHU from the joists due to the 18" of blown in insulation that will be going in this summer. I like the idea but this also make me nervous, anything I should be aware of with a hovering AHU?

**He did say he was installing a drip pan

__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 04-14-2013, 03:09 PM  
GBR
Senior Member
 
Join Date: Mar 2009
Posts: 337
Liked 18 Times on 17 Posts
Likes Given: 9

Default

As said already, you install a catwalk (per code; width) high enough to get full R-value to the unit from the scuttle hole. Cover exposed Romex within 6' of the attic access from walking on, per code. "Hanging from the joists" or maybe rafters- make sure they add additional vertical supports to a bearing wall below to carry the additional roof loads. Be sure your drywall can carry the additional insulation weight; https://docs.google.com/viewer?a=v&q=cache:z2U03nVAiDoJ:dsps.wi.gov/sb/docs/SB-UDCComm11Ch21.pdf+cellulose+ceiling+sag&hl=en&gl=u s&pid=bl&srcid=ADGEESiot8OQXJEGkeOMrbhSksDvkz-H6pCCr76zthh5_hADKh98mRY6ETzrBqsiSgbTi0bzQetw_ev6O-8Bf3SPC9Ygt2P-4ZfBTqVRAqAYNIPQ8l-V29hkDT8bAmfs0NXQ2Hxf51fE&sig=AHIEtbQixCH3AO0RugCG h3VLQNBaXp54rA

And if plaster/lath, the ceiling joists are able to take the weight as they are already at 8#per sq.ft., the extra weight may over-span them.
Air seal the attic now, optimum time- as you will benefit greatly;http://www.google.com/url?sa=t&source=web&cd=23&ved=0CCUQFjACOBQ&url=htt p%3A%2F%2Fapps1.eere.energy.gov%2Fbuildings%2Fpubl ications%2Fpdfs%2Fbuilding_america%2Fba_airsealing _report.pdf&rct=j&q=foam%20board%20in%20attic%20re quire%20thermal%20barrier%20with%20drywall%20alrea dy%20installed%20on%20other%20side%20of%20kneewall &ei=IvqWTveuIKW0sQK3zPzwBA&usg=AFQjCNHwd56o0AxL i8-V03E5cMUmwWATQw&cad=rja

Verify the attic ventilation requirements for your location, add more if needed (moisture on framing/exterior ice dams).

Gary

__________________
GBR is offline  
2
People Like This 
Reply With Quote Quick reply to this message
Old 04-15-2013, 04:51 PM  
drewdin
Junior Member
 
Join Date: Aug 2012
Posts: 391
Liked 25 Times on 22 Posts
Likes Given: 78

Default

@GBR, awesome tips! Thanks!

__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Old 04-16-2013, 02:43 PM  
drewdin
Junior Member
 
Join Date: Aug 2012
Posts: 391
Liked 25 Times on 22 Posts
Likes Given: 78

Default

So the Air handler is installed, I have an easy wiring question. The installer told me I needed a disconnect and an outlet per code. Is there a special disconnect I need to mount?I saw there was a 1/2" Knockout that was access to two hot terminals and a ground but no neutral. Does that sound correct? I know I am not in the right section of the forum, i can ask in the electrical section. Thanks



__________________
drewdin is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Attic Cross Member Question Rmwoiak Framing and Foundation 15 03-04-2013 09:10 PM
insulating the attic in my cape cod question daddymikey1975 Insulation and Radiant Barriers 3 08-15-2012 03:57 PM
Air handler will not blow davvid20120 HVAC 6 05-22-2012 09:39 AM
air handler problems dogface General Appliance Discussion 1 03-05-2012 08:12 PM
Question about attic venting Moggy Insulation and Radiant Barriers 13 12-30-2010 05:12 PM