DIY Home Improvement, Remodeling & Repair Forum

DIY Home Improvement, Remodeling & Repair Forum (http://www.houserepairtalk.com/forum.php)
-   HVAC (http://www.houserepairtalk.com/f8/)
-   -   Trane XE90 Board (http://www.houserepairtalk.com/f8/trane-xe90-board-12638/)

NathanHale 11-27-2011 04:13 PM

Trane XE90 Board
 
hello everyone,i am new to this forum. i have a trane xe90 gas furnace. i just changed the board on it. my question is the old board had two terminals marked "PARK". i want to know into which terminal on the new board do the wires go into, in the new board?i see two of them say park on the new one and i am confused as to which wire from the old board goes where.thank you

joecaption 11-27-2011 06:05 PM

Try talking to Trane on this one. There's been about a dozen other people on these boards asking about the exact same model # sounds like an older model that was a lemon.

paul52446m 11-27-2011 06:13 PM

Trane XE90 Board
 
Quote:

Originally Posted by NathanHale (Post 64391)
hello everyone,i am new to this forum. i have a trane xe90 gas furnace. i just changed the board on it. my question is the old board had two terminals marked "PARK". i want to know into which terminal on the new board do the wires go into, in the new board?i see two of them say park on the new one and i am confused as to which wire from the old board goes where.thank you

Not sure what you are asking, but here is the answer i think you are looking for.
Your blower has 4 speeds, you put the speed you want for heating on the heat post. You put the speed you want on cooling on the cool post. The last two unused wires speeds go on the two parks. So is you want the same speeds you
had before then put the same two colored wires on the two parks and the same colors wired you had before on cool and heat.
Does this answer your question? The parks are just unused motor leads.
Paul

NathanHale 11-27-2011 06:25 PM

Quote:

Originally Posted by paul52446m (Post 64395)
Not sure what you are asking, but here is the answer i think you are looking for.
Your blower has 4 speeds, you put the speed you want for heating on the heat post. You put the speed you want on cooling on the cool post. The last two unused wires speeds go on the two parks. So is you want the same speeds you
had before then put the same two colored wires on the two parks and the same colors wired you had before on cool and heat.
Does this answer your question? The parks are just unused motor leads.
Paul


does it matter if i mixed up the wires going into the "park" post? while i was transferring the wires from the old board to the new board i might have interchanged the "park"wires. i might have put the wire that is supposed to go on the top "park"post on the bottom and vice versa.

paul52446m 11-27-2011 06:35 PM

Trane XE90 Board
 
Quote:

Originally Posted by NathanHale (Post 64396)
does it matter if i mixed up the wires going into the "park" post? while i was transferring the wires from the old board to the new board i might have interchanged the "park"wires. i might have put the wire that is supposed to go on the top "park"post on the bottom and vice versa.

Makes no difference. They are dead post, just to put the unused motor leads on. They do not tie to anything in the board. It is important not to hot up more than one motor lead at a time, so that is why they give you post marked Park or spare. Any other questions? Paul

NathanHale 11-27-2011 06:38 PM

Quote:

Originally Posted by paul52446m (Post 64399)
Makes no difference. They are dead post, just to put the unused motor leads on. They do not tie to anything in the board. It is important not to hot up more than one motor lead at a time, so that is why they give you post marked Park or spare. Any other questions? Paul


thank you so much from PA!! Good night!!

paul52446m 11-27-2011 06:43 PM

Trane XE90 Board
 
Quote:

Originally Posted by NathanHale (Post 64400)
thank you so much from PA!! Good night!!

stay warm!!!! Paul