hello everyone,i am new to this forum. i have a trane xe90 gas furnace. i just changed the board on it. my question is the old board had two terminals marked "PARK". i want to know into which terminal on the new board do the wires go into, in the new board?i see two of them say park on the new one and i am confused as to which wire from the old board goes where.thank you



__________________
NathanHale is offline  
 
Reply With Quote Quick reply to this message
Old 11-27-2011, 06:05 PM  
joecaption
Senior Member
 
Join Date: Jan 2011
Location: Hartfield VA, VA
Posts: 1,359
Liked 36 Times on 31 Posts
Likes Given: 2

Default

Try talking to Trane on this one. There's been about a dozen other people on these boards asking about the exact same model # sounds like an older model that was a lemon.



__________________
joecaption is offline  
 
Reply With Quote Quick reply to this message
Old 11-27-2011, 06:13 PM  
paul52446m
Senior Member
 
Join Date: Oct 2010
Location: Houghton Lake, Mi.
Posts: 435
Liked 1 Times on 1 Posts

Default Trane XE90 Board

Quote:
Originally Posted by NathanHale View Post
hello everyone,i am new to this forum. i have a trane xe90 gas furnace. i just changed the board on it. my question is the old board had two terminals marked "PARK". i want to know into which terminal on the new board do the wires go into, in the new board?i see two of them say park on the new one and i am confused as to which wire from the old board goes where.thank you
Not sure what you are asking, but here is the answer i think you are looking for.
Your blower has 4 speeds, you put the speed you want for heating on the heat post. You put the speed you want on cooling on the cool post. The last two unused wires speeds go on the two parks. So is you want the same speeds you
had before then put the same two colored wires on the two parks and the same colors wired you had before on cool and heat.
Does this answer your question? The parks are just unused motor leads.
Paul
__________________
paul52446m is offline  
 
Reply With Quote Quick reply to this message
Old 11-27-2011, 06:25 PM  
NathanHale
Junior Member
 
Join Date: Nov 2011
Posts: 3
Default

Quote:
Originally Posted by paul52446m View Post
Not sure what you are asking, but here is the answer i think you are looking for.
Your blower has 4 speeds, you put the speed you want for heating on the heat post. You put the speed you want on cooling on the cool post. The last two unused wires speeds go on the two parks. So is you want the same speeds you
had before then put the same two colored wires on the two parks and the same colors wired you had before on cool and heat.
Does this answer your question? The parks are just unused motor leads.
Paul

does it matter if i mixed up the wires going into the "park" post? while i was transferring the wires from the old board to the new board i might have interchanged the "park"wires. i might have put the wire that is supposed to go on the top "park"post on the bottom and vice versa.
__________________
NathanHale is offline  
 
Reply With Quote Quick reply to this message
Old 11-27-2011, 06:35 PM  
paul52446m
Senior Member
 
Join Date: Oct 2010
Location: Houghton Lake, Mi.
Posts: 435
Liked 1 Times on 1 Posts

Default Trane XE90 Board

Quote:
Originally Posted by NathanHale View Post
does it matter if i mixed up the wires going into the "park" post? while i was transferring the wires from the old board to the new board i might have interchanged the "park"wires. i might have put the wire that is supposed to go on the top "park"post on the bottom and vice versa.
Makes no difference. They are dead post, just to put the unused motor leads on. They do not tie to anything in the board. It is important not to hot up more than one motor lead at a time, so that is why they give you post marked Park or spare. Any other questions? Paul
__________________
paul52446m is offline  
 
Reply With Quote Quick reply to this message
Old 11-27-2011, 06:38 PM  
NathanHale
Junior Member
 
Join Date: Nov 2011
Posts: 3
Default

Quote:
Originally Posted by paul52446m View Post
Makes no difference. They are dead post, just to put the unused motor leads on. They do not tie to anything in the board. It is important not to hot up more than one motor lead at a time, so that is why they give you post marked Park or spare. Any other questions? Paul

thank you so much from PA!! Good night!!
__________________
NathanHale is offline  
 
Reply With Quote Quick reply to this message
Old 11-27-2011, 06:43 PM  
paul52446m
Senior Member
 
Join Date: Oct 2010
Location: Houghton Lake, Mi.
Posts: 435
Liked 1 Times on 1 Posts

Default Trane XE90 Board

Quote:
Originally Posted by NathanHale View Post
thank you so much from PA!! Good night!!
stay warm!!!! Paul


__________________
paul52446m is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
cost to replace board on Trane XE90 Fitmiss HVAC 5 11-11-2011 06:01 PM
trane xe90 blower davidjackowiak HVAC 1 11-23-2010 01:52 PM
Trane XE90 problem MikeD1980 HVAC 3 09-14-2010 06:13 PM
Trane XE90 Furnace Billshouse HVAC 1 02-02-2010 04:35 PM
Trane XE90 TheGunMan HVAC 0 06-04-2009 04:53 PM