Default how many lights on a single light switch?

trying to start planning out lighting an unwired garage. it's about 30'x40' and i'd like to have maybe two regular 60-100 watt incandesant bulbs over each car position (8 lights).

i'm thinking about ceiling fans that are wired to one switch and may have 3-4 lights on them along with the fan it's self. could i put all 8 on one switch? or preferably two three way swtiches to cover two entrances?

if not, and maybe preferably, what about 4 on two pairs of three ways? that way i might save a bit of energy being able to light whichever side of the garage i'm on.

or a last option, since one car position is closed in like a small shop area, and has a flouresant(sp?) light over it already, have 6 lights over the cars on three way switches, and a couple lights over the shop area on their own switch.

dose any of this sound feasable?
Philphine is offline   Reply With Quote
Old 03-22-2007, 05:59 PM   #2
JoeD
Senior Member
 
Join Date: Mar 2006
Location: welland ontario
Posts: 133
Default

YOu can put up to 1800 watts on a 15 amp circuit. That fully loads it up and I would not go that high. Put up to 1400 watts of lighting if that is all that is on that circuit.

I would certainly make shop room separate lighting.
JoeD is offline   Reply With Quote
Old 03-22-2007, 06:55 PM   #3
Philphine
Member
 
Join Date: Feb 2007
Location: louisville, ky.
Posts: 66
Default

can i ask just to make sure i understand, 1800 watts on a 15 amp circuit, would that be like 18-100watt bulbs on one switch? if so i'm thinking should be safe. i think i will try 6 lights with the shop area separate (it's not really a separate room though. it just has like a big counter around it). thanks.
Philphine is offline   Reply With Quote
Old 03-22-2007, 09:21 PM   #4
Daryl in Nanoose
Senior Member
 
Daryl in Nanoose's Avatar
 
Join Date: Feb 2006
Location: Nanoose Bay BC
Posts: 675
Default

How about this. 2 3-way switches at each door. 1- for one car 2nd for other car and then a seperate switch for the work area.
Daryl in Nanoose is offline   Reply With Quote
Old 03-23-2007, 07:49 AM   #5
Philphine
Member
 
Join Date: Feb 2007
Location: louisville, ky.
Posts: 66
Default

Quote:
Originally Posted by Daryl in Nanoose View Post
How about this. 2 3-way switches at each door. 1- for one car 2nd for other car and then a seperate switch for the work area.
there are really three car postions. i think i'm going to try 6 and leave the shop area separate. one for each of 3 spots seems a little too much and separating one out seems like too much just for one car position, where before it would have been the one car and the shop area on one side, and two cars on the other. the doors are on the 30' side (two doors) and cars go in back to back on each side (1 car and shop area on one side).
Philphine is offline   Reply With Quote
Old 03-24-2007, 04:31 AM   #6
Snoonyb
Junior Member
 
Join Date: Sep 2006
Location: OC CA.
Posts: 24
Default

Or, 12, 4',T5 fl's on 3-3ways
__________________
Illigitimas non-carborundum
Snoonyb is offline   Reply With Quote
Old 03-29-2007, 07:42 PM   #7
AndyD5
The Cable Guy
 
Join Date: Mar 2007
Location: Chandler, Arizona
Posts: 48
Send a message via Yahoo to AndyD5
Default

You could wire a single pull switch into one of the three ways so that it operates that mentioned third area so it is only lit when you desire it. also those places you can use regular light bulbs like on the fans use compact florescent they put out almost as much light as a 60 watt bulb which is 850 Lumens but only use 13 watts producing 800 Lumens each and they are much cooler temperature wize they do work indoor or outdoors so having them exposed to weather is no factor, and there is no spring inside them to break as easily if you should bumb them lightly
__________________
-Andy the cable guy

I love to work on my house would love to help you with yours!
AndyD5 is offline   Reply With Quote
Old 03-29-2007, 08:24 PM   #8
Mach1
noob
 
Mach1's Avatar
 
Join Date: Nov 2005
Location: Midwest
Posts: 6
Default

I wired my (smaller than yours) garage with six 8' fluorescent light fixtures. The pair of lights in the center of the garage are on one 3-way switch leg coming from the house.

The 3-way switch leg coming from inside the house goes to a 4-way switch next to the rear-entry door of the garage, and from there to another 3-way at the front garage entry door. So I can turn on the center pair of lights in the garage weather I'm coming in from the back, front, or from the house.

The other 4 light fixtures are switched in pairs from inside garage. I did it this way so I could have lights on in the garage when I'm not in there without having to have all the lights on.

Joe Michel
Mach1 is offline   Reply With Quote
Old 04-17-2007, 10:54 AM   #9
JoulesWinfield
Member
 
Join Date: Dec 2006
Location: SE Michigan
Posts: 33
Default

All you have to do is make sure that you have a switched light at each entry door and that you have calculated the load based on the fixtures that you are using. Remember that flourescent lights are to be calculated by the rating of the ballast not the bulbs. If you are adding ceiling fans to the circuits make sure you account for the fan as well as the lights.

I like mach1's idea. Just have a couple lights, on a three/four way and put the rest on another switch. Or have all the lights for the cars on one switch and the fans on another. Or put everything on the switchs and use remote controlled fan/light combos. You could set two fan/lights on the same channel and operate both from one remote.
JoulesWinfield is offline   Reply With Quote
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Rare single-button light switch cshep975 Electrical and Wiring 17 12-02-2009 03:36 PM
rewire light from switch to light davidh424 Electrical and Wiring 3 01-12-2009 08:56 PM
Special Light Switch Required CraigFL Electrical and Wiring 9 02-20-2008 05:29 PM
Illuminated wall switch glows but bulbs won't light Paul in Maryland Electrical and Wiring 3 10-21-2007 08:34 AM
Single switch to receptacle jeff7 Electrical and Wiring 7 02-18-2007 09:01 AM



New!
Plumbing Forum

Search Forums


Sponsors

All times are GMT -6. The time now is 07:10 PM.

Bike & Cycling Forums × Airsoft Forum × Tractor Forum × Home Brewing Forum × Firearms & Gun Forums × Homesteading and Survival Forum × Jeep Forum