OK, I'd like to hear about the scariest electrical you have ever encountered.
Here is my opening contribution (pics to follow next week):

My next big job requires commercial electrical and plumbing in a medium sized, two story building. "The plumbing is easily access from underneath in the basement," says the owner. "But the basement is a little flooded. You'll have to install a new sump pump."

Down we got into the basement and I can see abou 1 1/2" of standing water in the 50'x35' finished portion. "Where can I see the space under the flooring," I ask.

"Turn left," he says as I hit the standing water, holding onto the wall ... so I turn left and in front of me is ... wait for it ... a 20' wall full of main and breaker panels, many of them with rust on the doors.

Before I do anything more next week, that basement will be pumped out till bone dry.



__________________

Last edited by CallMeVilla; 02-22-2013 at 05:54 PM.
CallMeVilla is offline  
 
Reply With Quote Quick reply to this message
Old 02-22-2013, 07:07 PM  
Fireguy5674
Junior Member
 
Join Date: Dec 2012
Location: Jacksonville, Illinois
Posts: 163
Liked 27 Times on 23 Posts
Likes Given: 17

Default

That is bad but your builing is still standing. When I was working as a firefighter, went to fire one night when of course it was about 0 degrees F. When the fire was out the whole roof structure of the brick building was burned off. During the after fire investigation it was discovered that some one had run #10 or #12 conductors directly off of 100 amp cartridge fuses to power the building. The building 2nd floor had collasped about 6 monthes earlier so they put a roof over the remaining bottom floor and "rewired".



__________________
Fireguy5674 is offline  
 
Reply With Quote Quick reply to this message
Old 02-22-2013, 09:38 PM  
CallMeVilla
Senior Member
 
CallMeVilla's Avatar
 
Join Date: Feb 2010
Location: San Diego
Posts: 1,179
Liked 335 Times on 264 Posts
Likes Given: 127

Default

Yeah, a friend was buying a house in Washington DC and called me panicked. She had discovered soot in the celing of the basement and wanted to know what to do. The sellers were "highly motivated" to move and close "any" deal ... I told her to open the ceiling and look ... Discovered there had been a fire and most of the livingroom floor joists were burned or blackened. The wiring was cooked too. Kind of explained the bouncy floor, eh?

She demanded a $20,000 set aside to close the deal ... and got it. We fixed the damage for $9,500 and put the rest into repairs elsewhere in the house. At first, it was VERY scary when we opened up the celing ... but all turned out great.

__________________
CallMeVilla is offline  
 
Reply With Quote Quick reply to this message
Old 02-23-2013, 11:10 AM  
Fireguy5674
Junior Member
 
Join Date: Dec 2012
Location: Jacksonville, Illinois
Posts: 163
Liked 27 Times on 23 Posts
Likes Given: 17

Default

I am remoleding my home of 3 years right now. (I should be finishing drywall as I type.) I have found several different places where someone took the 1940's wiring (big, black fiber wrapped wires. You know the stuff) cut it off, wire nutted new 12-2/w ground to it and buried the connections in the wall. I have found a couple of places where they actually used boxes for a doing the same but still buried them in the wall. One stage newer work. When we first moved in the almost new 40 gal electric water heater would barely keep up with two people. When I moved the main breaker box I realized the the # 10 wire was hooked up to the water heater correctly and was hooked to a 20 amp single pole breaker at the panel and the second leg was hooked into the neutral bar. It works much better now.

It is a wonder more places don't burn.

__________________
Fireguy5674 is offline  
 
Reply With Quote Quick reply to this message
Old 02-23-2013, 09:28 PM  
poppa
Junior Member
 
Join Date: Feb 2013
Posts: 17
Liked 1 Times on 1 Posts

Default

I once encountered a water heater that had been wired directly off the entrance cable before the fuse box. After pulling all fuses and thinking it was safe to cut the wire, I wound up with a pair of melted side cutters and blinded for a while from the flash. Thanks to the good lord I wasn't hurt but learned a valuable lesson when dealing with electricity in very old houses. Folks could be very creative when wiring in devices back then.

__________________
poppa is offline  
 
Reply With Quote Quick reply to this message
Old 02-24-2013, 06:26 AM  
wilard
Junior Member
 
Join Date: Feb 2013
Posts: 9
Default

Call me villa

You are very wise to pump out all water.. I had a freind who's brother was killed going into a flooded basement to clean out a drain electricity and water do not mix



__________________
wilard is offline  
 
Reply With Quote Quick reply to this message
Reply


Quick Reply
Message:
Options

Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Am I using the right stuff? davecuz Flooring 2 10-19-2010 08:25 AM
More free stuff inspectorD Tools 6 12-09-2008 05:33 AM
Free Stuff PaPaDan Tools 11 12-02-2007 07:07 PM
New Guy With Old Stuff Bull Introductions 2 11-23-2007 11:13 PM