Posted in thread: York stellar plus keeps shutting down on 01-05-2010 at 04:26 AM
a volt meter will tell all ....find out what the ohms is on the sensor and it tell you what the
min.is ,,,Posted in thread: lux air furnace on 01-04-2010 at 07:06 PM
make sure you have a good ground at the igniter remove it carefully use some sand paper where
the igniter mounts to for a good ground reinstall and see what happens ....but before you put
it back look...Posted in thread: Oil Burner Acting Up. Help! on 01-04-2010 at 06:56 PM
lets not forget depending on what type of oil pump you have there is a strainer in it ....so if
it was a strainer you just spent 100 plus dollars on a pump compared to 5.00 for a strainerPosted in thread: Oil Burner Transformer on 01-04-2010 at 06:50 PM
if the be Beckett Burner is new it will have a solid state transformer ...you can tell it's
made of plastic it's a one time failure it does not get week over time. it will let you down
and fail ...if ...