Posted in thread: Gas Furnace Blower/Fan Occasionally Keeps Running on 01-24-2013 at 09:37 PM
Replace the limit switch the black square with the 2 red wires, its a wafer switch that can be
intermittent when closed it tells the blower there is heat a to turn on.Posted in thread: York Stellar Plus flame won't say lit for more than a second on 01-24-2013 at 09:24 PM
Your problem is the flame sensor, the long sensor that you used sandpaper on is the flame
sensor and you should lightly clean with scotch brite or sandpaper each fall before winter.
This senses the fl...Posted in thread: Blower Motor on 01-24-2013 at 09:19 PM
My earlier post was incorrect. My problem is the blower motor starts when heat cycle starts.
When draft inducer starts so does the blower. Everything works ok its just that the blower
shouldn't start ...Posted in thread: Draft inducer fan on 01-24-2013 at 07:53 AM
hello, My problem is that the Draft inducer fan runs through the entire cycle. Normally this
fan would shut down at blower motor start up but instead continues to run until heat cycle is
complete. Yor...