  • Posted in thread: Lennox compressor won't stay on on 08-19-2009 at 07:12 PM
    Sounds like you are low on freon which would cause compressor to go "off" on low pressure
    switch-pressure switch is located inside condensor. Check system charge.

  • Posted in thread: Freon copper in the wall and condensation pump in the attic on 08-19-2009 at 06:57 PM
    Have the condensate pump wired in series with the control voltage-wired this way if the pump
    fails the unit will not come "on" and you will know you have a problem- this will happen before
    it overflow...

  • Posted in thread: York attic thru the wall a/c on 08-19-2009 at 06:33 PM
    did not change blade for condensor-evaporator is a sqiurrel cage. this is the 2nd motor-(after
    thinking i had elimated all other possibllities i came to the same conclusion). i am working
    behind a ano...

  • Posted in thread: York attic thru the wall a/c on 08-19-2009 at 04:37 AM
    double shaft motor-old unit

  • Posted in thread: York attic thru the wall a/c on 08-17-2009 at 01:55 PM
    looking for some suggestions. unit has a double shafted motor whitch is going off on internal
    thermal overload. this is a new manufactures suggested replacement motor. amps,rpm's, and
    voltage are iden...