  • Posted in thread: carrier model 50js--048--301 on 06-02-2013 at 09:58 PM
    Take off the panel right above where your lineset connects on the unit. The capacitor should be
    in there. Remember to kill the power before digging around in there. Have fun!

  • Posted in thread: New House, New Problems on 06-01-2013 at 10:11 PM
    Shut the power off to your furnace. Get a volt meter and head outside to your a/c condensing
    unit. Shut off the disconnect and gain access to the electrical. Remove the two wires going to
    the contacto...

  • Posted in thread: No power to my thermostat on 05-31-2013 at 10:29 PM
    Those darn condensate pumps and their safety features! Usually don't see this issue unless
    furnace/air handler is installed in an attic or upstairs area. But good post about what could
    be a possibly o...

  • Posted in thread: Opinion on service charge on 05-31-2013 at 10:21 PM
    Thats sounds about right to me. As stated by kok328, the price of R22 has gone way up due to it
    being phased out. The other option would be to take this oppurtunity to update your system to a
    R410A co...

  • Posted in thread: Size of intake vent? on 05-18-2013 at 05:40 PM
    I take it this isn't the only return air for the furnace? You need to have the same square
    inches of return as you do of supply. So say you are bringing 2 6" runs into your bedroom, this
    calculates to...

  • Posted in thread: Looking for new HVAC and move furnace? on 04-19-2013 at 06:42 PM
    Oh and upgrade that dinosaur furnace to an energy efficient one while your spending the money.
    It will be a lot quieter as :D

  • Posted in thread: Looking for new HVAC and move furnace? on 04-19-2013 at 06:39 PM
    Centralizing in the attic is a viable option as long as it is installed correctly. Drip pan
    under the entire unit with a drain, everything insulated properly, unit supported properly with
    proper braci...

  • Posted in thread: Carrier furnace short cycling on 04-19-2013 at 06:25 PM
    4 minutes is way too long between when the burners ignite and when the blower motor comes on.
    Sounds like its shutting down on high limit, cooling down when the blower comes on, closing the
    limit swit...

  • Posted in thread: Help with Trane Model 2TWB3030A1000A on 04-19-2013 at 06:12 PM
    Anyway if that's the case it sounds like your reversing valve coil may have failed in the
    winter heating months. If this is the case it usually fails open which would still allow it to
    heat fine. Your...

  • Posted in thread: Help with Trane Model 2TWB3030A1000A on 04-19-2013 at 05:38 PM
    So you are saying that the condenser fan will start up again after it comes to a stop if you
    spin it manually? And that you changed the capacitor without testing it and it didnt help the
    situation? Al...