Posted in thread: York Stellar Plus won’t ignite on 11-17-2008 at 07:38 AM
Unit continues to work fine, tested by temps in the 20-s at night couple of times.York part #
for FLAME ROLLOUT switch pictured in post #12 is 025-26908-000 and I bought it real cheap
hereThank to kok...Posted in thread: York Stellar Plus won’t ignite on 11-11-2008 at 10:07 AM
Works for now(fingers crossed).Turned out inducer blower was working, but not good enough to
close the pressure switch.Removed inducer blower, vacuumed inside, rotated fan manually.Removed
flue collec...Posted in thread: York Stellar Plus won’t ignite on 11-09-2008 at 12:44 PM
Some history:At the end of last heating season this unit would ignite burners and after a short
while the flame would go out. I left it at that till new season, and when decided to take a
look – it wo...Posted in thread: York Stellar Plus won’t ignite on 11-09-2008 at 08:07 AM
Yea, that would fall under the "got his heat working" catagorey. Lord knows, I wasn't getting
him anywhere.You helped a lot and it's much appreciated , especially as problem still stands.I
was just di...Posted in thread: York Stellar Plus won’t ignite on 11-04-2008 at 03:50 PM
the switch/fuse has no continuity, needs to be replaced.I searched for exact same one, found
info but no place to buy it.It opens at 152 degrees C or 306 F.I think it was not supposed to
be there. Is ...Posted in thread: York Stellar Plus won’t ignite on 11-04-2008 at 08:16 AM
You were right on!The switch! First I didn’t see anything in the burn chamber, then
looked in our main unit York Diamond 80 and saw the cylinder switch! In this small broken unit
same wires just...Posted in thread: York Stellar Plus won’t ignite on 11-03-2008 at 12:18 PM
sure feels like something stupid (disconnected wire), before the pressure switches.Found
troubleshotting manual for control board through chart 1(page 2)with inducer running there is
25v between C an...Posted in thread: York Stellar Plus won’t ignite on 11-02-2008 at 08:25 AM
There is what I suspect is a limit switch, round with 3 tabs, has too many wires connected, how
to check it ?Checked pipes – clean.This unit is heating/cooling and cooling is fine, I
had to say ...Posted in thread: York Stellar Plus won’t ignite on 11-01-2008 at 03:31 PM
Gas is on; blue switch inside and red outside. Pressure switches not connected with each
other.LEFT one(with 3 wires) connected by tube to inducer motor. Tube from the RIGHT
switch(with 2 wires) split...Posted in thread: York Stellar Plus won’t ignite on 11-01-2008 at 08:55 AM
Ignator looks like this electronic means no pilot light, then it's electronic.Normally it
should glow, but does nothing.Somethere I read(not about my model), that there should be 115 v
coming to igna...
Leave CommentNewest Threads
- Small cabin help..?
- Basement Plumbing and Flooding Questions
- Your house is how old?
- Paint Chiping in Bathtub
- Driveway Sealer
- drylocking basement and removing mold on concrete
- Bathroom tiling
- Flooding Driveway
- One Word Game
- Completed Sanding, two questions before applying urethane finish.
- Install Quarter Round when there is large gap underneath the baseboard?
- Sistering floor joists in my hunting cabin to stop floor movement
- Shower pan
- Need opinions on what to do here... (Pics Included)
- Possible mold problems??
- Need some help





Browse Members
Register