VIEW MY

rodge

Gift Premium Subscription To rodge

Join Date:

11-01-2008

Last Activity:

04-22-2009 8:59 AM

    ABOUT ME

  • diy
  • rodger bryskin

LATEST ACTIVITY

  • Posted in thread: York Stellar Plus wont ignite on 11-17-2008 at 07:38 AM
    Unit continues to work fine, tested by temps in the 20-s at night couple of times.York part #
    for FLAME ROLLOUT switch pictured in post #12 is 025-26908-000 and I bought it real cheap
    hereThank to kok...

  • Posted in thread: York Stellar Plus wont ignite on 11-11-2008 at 10:07 AM
    Works for now(fingers crossed).Turned out inducer blower was working, but not good enough to
    close the pressure switch.Removed inducer blower, vacuumed inside, rotated fan manually.Removed
    flue collec...

  • Posted in thread: York Stellar Plus wont ignite on 11-09-2008 at 12:44 PM
    Some history:At the end of last heating season this unit would ignite burners and after a short
    while the flame would go out. I left it at that till new season, and when decided to take a
    look it wo...

  • Posted in thread: York Stellar Plus wont ignite on 11-09-2008 at 08:07 AM
    Yea, that would fall under the "got his heat working" catagorey. Lord knows, I wasn't getting
    him anywhere.You helped a lot and it's much appreciated , especially as problem still stands.I
    was just di...

  • Posted in thread: York Stellar Plus wont ignite on 11-04-2008 at 03:50 PM
    the switch/fuse has no continuity, needs to be replaced.I searched for exact same one, found
    info but no place to buy it.It opens at 152 degrees C or 306 F.I think it was not supposed to
    be there. Is ...

  • Posted in thread: York Stellar Plus wont ignite on 11-04-2008 at 08:16 AM
    You were right on!The switch! First I didn’t see anything in the burn chamber, then
    looked in our main unit York Diamond 80 and saw the cylinder switch! In this small broken unit
    same wires just...

  • Posted in thread: York Stellar Plus wont ignite on 11-03-2008 at 12:18 PM
    sure feels like something stupid (disconnected wire), before the pressure switches.Found
    troubleshotting manual for control board through chart 1(page 2)with inducer running there is
    25v between C an...

  • Posted in thread: York Stellar Plus wont ignite on 11-02-2008 at 08:25 AM
    There is what I suspect is a limit switch, round with 3 tabs, has too many wires connected, how
    to check it ?Checked pipes – clean.This unit is heating/cooling and cooling is fine, I
    had to say ...

  • Posted in thread: York Stellar Plus wont ignite on 11-01-2008 at 03:31 PM
    Gas is on; blue switch inside and red outside. Pressure switches not connected with each
    other.LEFT one(with 3 wires) connected by tube to inducer motor. Tube from the RIGHT
    switch(with 2 wires) split...

  • Posted in thread: York Stellar Plus wont ignite on 11-01-2008 at 08:55 AM
    Ignator looks like this electronic means no pilot light, then it's electronic.Normally it
    should glow, but does nothing.Somethere I read(not about my model), that there should be 115 v
    coming to igna...

0 COMMENTS
POST A COMMENT