Posted in thread: L flashing used on new roof ok? on 12-13-2011 at 02:22 PM
My contractor said theres 2 problems. He said metal studs is hard to nail too, and you would
have to nail the step flash high; so he would not be able to put blocking up without taking the
hardie boar...Posted in thread: L flashing used on new roof ok? on 12-12-2011 at 11:54 AM
I will present ideas to my contractor when he shows up. He said the top half is the hard part.
It's not hardie plank but 2 large sheets of hardie board and the brown trim piece. I will
present these s...Posted in thread: L flashing used on new roof ok? on 12-10-2011 at 12:29 PM
My contractor is going to send his roofer out next week to take a look to see if step can be
put over the L flashing. I had too other roofing companies come out to look at the job. Both
said they prob...Posted in thread: L flashing used on new roof ok? on 12-07-2011 at 01:16 AM
Yes thats correct. He left the siding in place, and on the right side there is a hole from the
original roof, he covered it with tyvek. Above the new roof he just chalked a 3" line and cut a
hole foll...Posted in thread: L flashing used on new roof ok? on 12-06-2011 at 06:52 PM
Hey guys I'm assuming that where the original roof was it had blocks. Also it's a 2 story house
so I don't believe its accessable from the attic. What do you think about putting the step over
the L fl...Posted in thread: L flashing used on new roof ok? on 12-06-2011 at 01:57 PM
I talked to him today. He said the reason he did not use step is the tight space and also there
is no blocking behind. He used the metal studs as blocking. He said the previous roof had
blocking built...Posted in thread: L flashing used on new roof ok? on 12-05-2011 at 09:22 AM
Joe caption your right. Also thats not counter flashing, that IS the flashing. Thousands of
these half to 1 million homes are made with no sheathing behind the hardie plank, hardie board.
Also If I do...Posted in thread: L flashing used on new roof ok? on 12-04-2011 at 10:51 PM
certainteed.Posted in thread: L flashing used on new roof ok? on 12-04-2011 at 07:15 PM
I agree with all of you 100%. I'm just trying to figure out a solution. This contractor was
highly recomended by a good friend of mine. Turns out this contractor knows people I
know.(Thats what happen...Posted in thread: L flashing used on new roof ok? on 12-03-2011 at 01:55 AM
Yes the soffit has vent holes in everyone. What will happen if they leave the track flashing?
Should kickout flashing be used also? Also there is no sheathing behind the hardieplank, that
is how all t...
Leave CommentNewest Threads
- Tearing up ground level deck to deal with drainage issues at rear of house
- Floor Drain for AC Condensate Discharge
- Small hairline cracks in fiberglass balcony
- Fastening to vinyl siding
- Builder's Joke Thread
- Removing Shower Door/Frame Nails?
- Stainless Steel Fridge
- One Word Game
- Building a Time Machine
- New construction door in pole barn with ribbed aluminum siding
- Need to temporarily remove A/C to replace decking
- Replacing Prehung Front Entry Door in Stucco
- My cat is a moron, again
- preparing yard for grass
- Stucco Job
- moisture from missing singles at roof peak?





Browse Members
Register