DIY Home Repair Forum: Plumbing Forum 06-27-2013, 02:37 PM
Replies: 29
Views: 2,911
Posted By pumpguy
A shallow well might make it to shut off...

A shallow well might make it to shut off pressure, but not a deep well. It maybe doubtful that a 240v pump will run on 115v, but it does happen.
DIY Home Repair Forum: Plumbing Forum 06-27-2013, 01:34 PM
Replies: 29
Views: 2,911
Posted By pumpguy
You would be surprised. I have had them working...

You would be surprised. I have had them working that way for years. They just won't build enough pressure to shut off.
DIY Home Repair Forum: Plumbing Forum 06-27-2013, 01:27 PM
Replies: 29
Views: 2,911
Posted By pumpguy
Check the voltage at L1 and L2 either on the...

Check the voltage at L1 and L2 either on the outlet side of the pressure switch or at the control box.
DIY Home Repair Forum: Plumbing Forum 06-27-2013, 12:13 PM
Replies: 29
Views: 2,911
Posted By pumpguy
Make sure you have 240 volts to the pump. Half...

Make sure you have 240 volts to the pump. Half power or 115 volts can make it act that way, and could have happened during a power outage.
DIY Home Repair Forum: Plumbing Forum 04-11-2013, 07:36 AM
Replies: 10
Views: 2,020
Posted By pumpguy
It sounds like your pump or well is not producing...

It sounds like your pump or well is not producing enough water.