Posts Made By:
thermalmedics
DIY Home Repair Forum:
HVAC
04-19-2012, 10:48 AM
Replies:
4
Has the price of R22 just doubled?
Views:
707
Posted By
thermalmedics
In January the EPA mandated a 45% reduction in...
In January the EPA mandated a 45% reduction in future production of R-22 in line with the scheduled phase-out. Prices immediately doubled nationwide.
Sad to see it happen because I think 22...
DIY Home Repair Forum:
HVAC
04-10-2012, 10:08 AM
Replies:
5
Lennox compressor won't stay on
Views:
1,459
Posted By
thermalmedics
anyone coming across this problem can refer to...
anyone coming across this problem can refer to these videos on low voltage and high voltage troubleshooting at the contactor
you tube vid high voltage
http://www.youtube.com/watch?v=ZArkm-OkF0g...
DIY Home Repair Forum:
HVAC
04-04-2012, 03:17 PM
Replies:
4
Goodman Indoor Unit Rusty Coils
Views:
422
Posted By
thermalmedics
thats right on. the aluminum is the outer shell...
thats right on. the aluminum is the outer shell with copper piping inside where the pressure is. take a look at this a coil in the video here
http://www.youtube.com/watch?v=dkbsuo6w5aI
you...
DIY Home Repair Forum:
HVAC
03-30-2012, 10:09 PM
Replies:
5
Lennox Compressor wont turn on
Views:
3,415
Posted By
thermalmedics
that's good advice back in the day we were told...
that's good advice back in the day we were told to hawk those like crazy. I always hated it because it was a way to generate more service calls for the company. Now I just teach people how to check...
DIY Home Repair Forum:
HVAC
03-30-2012, 09:56 PM
Replies:
6
Air handler will not blow
Views:
3,181
Posted By
thermalmedics
check this
along with that great advice I would rule out the thermostat and low voltage wiring issues.
1. pull the thermostat cover off of the wall. touch red to green wires together. does the blower...
DIY Home Repair Forum:
HVAC
03-30-2012, 09:47 PM
Replies:
3
A Trane XR13 outdoor fan
Views:
1,334
Posted By
thermalmedics
So the outdoor fan motor will not come on in...
So the outdoor fan motor will not come on in cooling or heating right? kok328's advice is right on.
1. I would pull power to the outdoor unit - you tube vid on how here-
2. with stick or...
DIY Home Repair Forum:
HVAC
03-24-2012, 07:45 AM
Replies:
5
Lennox Compressor wont turn on
Views:
3,415
Posted By
thermalmedics
can be frustrating
There are a lot of DIY friendly A/C fixes and there are some that just flat out need a professional. At least you wont ever have that problem again and have to pay through the nose!!
I got into...
DIY Home Repair Forum:
HVAC
03-22-2012, 01:26 PM
Replies:
5
Lennox Compressor wont turn on
Views:
3,415
Posted By
thermalmedics
check on the ask me help. gotcha some info
check on the ask me help. gotcha some info
DIY Home Repair Forum:
HVAC
03-14-2012, 02:56 PM
Replies:
6
Is it possible to inspect ducting for holes from inside? Or is this a sci-fi realm?
Views:
356
Posted By
thermalmedics
try the door trick
this door trick is a useful way (http://phxheatpump.blogspot.com/2012/02/how-do-i-know-i-have-duct-leak-old-door.html) I find to narrow the leak down to a return or supply line. If there are...
DIY Home Repair Forum:
HVAC
03-08-2012, 08:22 AM
Replies:
2
Getting rid of air intake
Views:
455
Posted By
thermalmedics
details
1. do you have a split system (http://www.thermal-medics.com/a-c-image-glossary/)or package unit (http://www.thermal-medics.com/a-c-image-glossary/)on the rooftop (im thinking you referred to a...
DIY Home Repair Forum:
HVAC
03-08-2012, 08:07 AM
Replies:
4
new HVAC :air quality problems
Views:
284
Posted By
thermalmedics
be sure there is not a leak
If you are just starting to notice the dust and insulation in the home I would definately rule out a duct leak.
Since the unit is new there is a possiblity that a leak developed during...
DIY Home Repair Forum:
HVAC
02-29-2012, 09:24 AM
Replies:
8
Remove blower motor on Convertible Trane (American Standard) Air handler
Views:
1,181
Posted By
thermalmedics
would work
The motor will probably work ok for awhile. Just curious why you dont replace it with an actual blower motor?
The two motors are cooled differently via airflow. Blower motors have openings on...
DIY Home Repair Forum:
HVAC
02-28-2012, 12:56 PM
Replies:
8
Remove blower motor on Convertible Trane (American Standard) Air handler
Views:
1,181
Posted By
thermalmedics
couldnt be the metal grinding
its not the metal grinding from the squirl cage fan is it? ive heard a lot of godawful and that is definately one you dont forget.
once the blower motor gets up to speed maybe the inner squirl...
DIY Home Repair Forum:
HVAC
02-28-2012, 09:51 AM
Replies:
8
Remove blower motor on Convertible Trane (American Standard) Air handler
Views:
1,181
Posted By
thermalmedics
short version
Steve,
sorry, short version not the novel...
remove squirrl cage assembly and it all slides out
DIY Home Repair Forum:
HVAC
02-28-2012, 09:31 AM
Replies:
8
Remove blower motor on Convertible Trane (American Standard) Air handler
Views:
1,181
Posted By
thermalmedics
blower motor
After pulling power to the air handler discharge the run capacitor for the blower motor. Just use and insulated screwdriver and touch both terminals WHILE HOLDING INSULATED HANDLE.
TAKE PICS OF...
DIY Home Repair Forum:
HVAC
02-26-2012, 09:13 PM
Replies:
13
Heat Pump Aux. heat running too often.
Views:
3,790
Posted By
thermalmedics
Sweeeeeeeeeeeeeeeeeeeeeeet!!!
Score one for the good guy!!!!!!!!!!!!!!!!!!!!!
Nice job dude
DIY Home Repair Forum:
HVAC
02-26-2012, 10:08 AM
Replies:
9
Im in trouble! Gotta big leak. Help if you can.
Views:
411
Posted By
thermalmedics
how bout the leak
So how bout the leak? Did it all blow out at the compressor when the wire set blew out. that is some serious meltage on the compressor housing. I have seen hard start kits hooked up to locked up...
DIY Home Repair Forum:
HVAC
02-20-2012, 07:29 AM
Replies:
13
Heat Pump Aux. heat running too often.
Views:
3,790
Posted By
thermalmedics
fun times
This is where things get fun. I have seen a ton of this crap by home warranty companies.....
here are a few questions to ponder aloud with the home warranty co.
1. They 'covered' the unit...
DIY Home Repair Forum:
HVAC
02-12-2012, 09:08 PM
Replies:
13
Heat Pump Aux. heat running too often.
Views:
3,790
Posted By
thermalmedics
dyes work
yes there is some dye type stuff you can dump in and look for. If it is leaking that much than it shouldnt take anyone too long to find it out. Dump whats left of the charge and fill it with...
DIY Home Repair Forum:
HVAC
02-11-2012, 09:42 AM
Replies:
13
Heat Pump Aux. heat running too often.
Views:
3,790
Posted By
thermalmedics
hot compressor
If the tech ohmed out the compressor when it was hot it would show an open (IP) or internal protection that it has to stop it from burning up. Often like DIY Mike says many compressors are condemed...
DIY Home Repair Forum:
HVAC
02-10-2012, 10:12 PM
Replies:
9
24vac transformer frenquently burns out
Views:
2,149
Posted By
thermalmedics
check wiring as well
I have seen a few repeat transformer problems that are caused by stripped wiring or bad connections. Copper wire will heat up and start drawing current and smoke a 24v secondary side of the...
DIY Home Repair Forum:
HVAC
02-10-2012, 11:16 AM
Replies:
4
Another Trane blower issue
Views:
635
Posted By
thermalmedics
blower motor
If you are getting functionality with the other elements of the system. Exhaust motor, T-stat operation etc then I would be looking at the blower motor and run capacitor.
After disconnecting...
DIY Home Repair Forum:
HVAC
02-10-2012, 09:58 AM
Replies:
2
Heat Pump Repairs
Views:
453
Posted By
thermalmedics
DIY advice
You mentioned how can we trust them?
I am in Phoenix and have worked as an HVAC service tech doing all of it. I now work as a consumer advocate in the field.
#1 many companies pay service...
Showing results 1 to 23 of 23
All Sponsors:
IMPERIAL BLADES
DumpsterSpot.com
Newest Threads
My cat is a moron, again
This is a Test Thread
Ideas to decor Small Bathroom
New construction door in pole barn with ribbed aluminum siding
Need to temporarily remove A/C to replace decking
Building a Time Machine
preparing yard for grass
Stucco Job
Replacing Prehung Front Entry Door in Stucco
moisture from missing singles at roof peak?
glue or thin set ?
Transistion problem
Builder's Joke Thread
Mucisians
Happy Father's Day
One Word Game
FOLLOW US ON