triple D
DIY Home Repair Forum:
Electrical and Wiring
11-20-2010, 07:20 PM
Replies:
3
wiring "issues"
Views:
611
Posted By
triple D
you can save it...
You will need to go and get about 75 or so purple wire nuts for aluminum to copper splice. These are the only ul listed and code approved way to do this. Count up all switches single pulls and three...
DIY Home Repair Forum:
Electrical and Wiring
09-18-2010, 09:30 PM
Replies:
11
Service Outlet
Views:
788
Posted By
triple D
just to clarify...
the outlet in the basement ten feet away would of been fine for service plug code, if it was a gfi. You must have one within 25 ft of furnace. Adding the one you did, you are correct in naming it the...
DIY Home Repair Forum:
Electrical and Wiring
09-16-2010, 10:15 PM
Replies:
11
Service Outlet
Views:
788
Posted By
triple D
code requires gfi..
the service/convience outlet located in relation to furnace must be gfi protected, as it is assumed repair personnel will be utilizing this to do there duties on the furnace. I think if I looked...
DIY Home Repair Forum:
Electrical and Wiring
09-16-2010, 10:00 PM
Replies:
2
Inaccessable outlet - remote control?
Views:
583
Posted By
triple D
hire someone....
A real electrician should be able to get both plugs switched from one location. Probably with no damage to walls at all if there is access above or below. Maybe close in cost to. Just a thought, good...
DIY Home Repair Forum:
Electrical and Wiring
09-13-2010, 01:11 AM
Replies:
3
battery backup for sump pump?
Views:
3,403
Posted By
triple D
use a marine pump....
Depending on how much water you need to move, and how fast, you could put a bildge pump in there. Then cut the float switch off and wire to a standard sump float. Use two deep cycle batteries, and go...
DIY Home Repair Forum:
Electrical and Wiring
09-06-2010, 09:52 PM
Replies:
6
Ceiling Fan Wiring
Views:
1,031
Posted By
triple D
light bulbs?
If you have flourescent bulbs, you will also go through dimmers.
DIY Home Repair Forum:
Electrical and Wiring
09-06-2010, 09:41 PM
Replies:
5
Popping GFI but not non-GFI outlets - need help
Views:
985
Posted By
triple D
what?
Is the extension cord wired to the lugs of breaker box directly with no splices along the way? And you have the black white and green unhooked? If this is the case the cord needs to be replaced, it...
DIY Home Repair Forum:
Electrical and Wiring
08-16-2010, 06:27 PM
Replies:
17
HOT and NEUTRAL both reading 120V???
Views:
9,411
Posted By
triple D
o.k. here it is....
If the nail or screw had touched the hot to the neut as you earlier indicated causing some kind of 120volt anomoly on the neut, you would blow the breaker in less than a second. you would never have...
DIY Home Repair Forum:
Electrical and Wiring
08-16-2010, 06:12 PM
Replies:
4
What should I do with this wire?
Views:
704
Posted By
triple D
is that comfortable?
If it is a pain to get to either end, just set a skill saw to cut 3/4 inch into studs, and cut a path from a to b that is 1 inch wide then staple wire to back of notches and put a metal nail plate...
DIY Home Repair Forum:
Electrical and Wiring
08-16-2010, 06:05 PM
Replies:
4
the difference bettween wet rated and damp rated?
Views:
744
Posted By
triple D
wow!!!
Is that your fan set up? Do you use it? Cause I dont think its to safe....
DIY Home Repair Forum:
Electrical and Wiring
08-08-2010, 12:47 AM
Replies:
8
Outlet gets voltage reading, but does not work
Views:
5,355
Posted By
triple D
try this dude....
I pull this trick once in a while at work when i'm stuck with the puke meter. Get an extension cord and take it to a good plug. Test hot to neut and to grnd should be the same both ways 118-125volts....
DIY Home Repair Forum:
Electrical and Wiring
08-08-2010, 12:33 AM
Replies:
17
HOT and NEUTRAL both reading 120V???
Views:
9,411
Posted By
triple D
precisley!
That is exactly correct Joe, your trouble shooting skills are right on. The neutral slowly burned itself the rest of the way apart over time. The breaker would of never held, from the time the screw...
DIY Home Repair Forum:
Electrical and Wiring
07-30-2010, 12:05 AM
Replies:
8
natural gas-powered generator inside home?
Views:
1,494
Posted By
triple D
why inside??????
Just have to know why inside, I'll check codes but I'm pretty sure this one might be a no go. To many factors at hand. Is there no room outside? How big do you need it?
DIY Home Repair Forum:
Electrical and Wiring
07-29-2010, 11:58 PM
Replies:
4
Dryer blowing fuse
Views:
2,525
Posted By
triple D
check the cord
turn off breaker, then pull dryer out and unplug cord. Look at the prongs to see if surrounding rubber is dark and melted. Then remove cover on dryer over cord connection. Check that all nuts or...
DIY Home Repair Forum:
Electrical and Wiring
07-28-2010, 12:06 AM
Replies:
2
Noalax necessary?
Views:
667
Posted By
triple D
yes wire nut....
You take alum. to alum. or copp. to alum. and put together like regular junction, except you must only use a purple wire nut. It might be filled with the substance you mentioned....But you cannot...
DIY Home Repair Forum:
Electrical and Wiring
07-11-2010, 09:51 AM
Replies:
7
ceiling fan remote
Views:
761
Posted By
triple D
canopy....
the vast majority are mounted in ceiling canopy.
DIY Home Repair Forum:
Electrical and Wiring
07-11-2010, 09:47 AM
Replies:
11
any rule of thumb for figuring max recommended bulb wattage?
Views:
1,349
Posted By
triple D
rating????
I think the deciding factor here is, what is the temp. rating of wire you used to wire fixture internally. Just curious, did you hook a grnd. tail to fixture? It looks like a pretty cool light, good...
DIY Home Repair Forum:
Electrical and Wiring
07-01-2010, 12:00 AM
Replies:
6
Telephone line wiring?
Views:
734
Posted By
triple D
what line?
I know this post is old, and they probably have a phone by now. But was there even an existing line anywhere in their proposed half of the house?
DIY Home Repair Forum:
Electrical and Wiring
06-26-2010, 08:32 AM
Replies:
6
grounding breaker panel
Views:
2,098
Posted By
triple D
5 feet
what did'nt show up in speedy's post is the number 5 before the 'symbol. you must be within 5' of the foundation or slab (where the pipe enters the building line) when you hook to water line. And you...
DIY Home Repair Forum:
Electrical and Wiring
06-25-2010, 11:25 PM
Replies:
6
grounding breaker panel
Views:
2,098
Posted By
triple D
rods.....
is your entire house plastic plumbing including main line coming in? if so you should have two ground rods outside, with a #6 copper to them from neutral bar.
DIY Home Repair Forum:
Electrical and Wiring
06-20-2010, 11:29 PM
Replies:
1
Mounting Checkolite pot rack with lighting
Views:
625
Posted By
triple D
cant get instructions
your link is not working for me, web page cannot be found.....could help ya if I could see what is not in the top of other link(mounting plate)
DIY Home Repair Forum:
Electrical and Wiring
06-20-2010, 11:23 PM
Replies:
8
help with 3 way wiring
Views:
1,111
Posted By
triple D
try this....
turn off power and disconnect all wires on the two single pole switches on right.(i know your using three ways for these, and thats fine, well get to that in a minute) Turn power on and test the blk...
DIY Home Repair Forum:
Electrical and Wiring
05-28-2010, 07:14 PM
Replies:
6
Dual Brite Porch Lights
Views:
2,789
Posted By
triple D
polarity???
Have you varified line and load? Not just by color, but with a volt detector?
DIY Home Repair Forum:
Electrical and Wiring
05-28-2010, 07:12 PM
Replies:
3
To sub or not to sub?
Views:
458
Posted By
triple D
yeah.....
You are in referance to copper? also keeping the grounds all tied to grnd bar, tied to panel box, and keeping all neutrals together on a floating bar, seperate from grounds? Yah that sounds like your...
DIY Home Repair Forum:
Electrical and Wiring
05-28-2010, 07:03 PM
Replies:
3
Change from 220V to 110V (& Gas line install)
Views:
3,090
Posted By
triple D
I cant believe my eyes!!!!!
That device must be made in china! How the hell does the other end get changed to a 15 or 20 amp single pole breaker? further more, that is for a 4 wire plug. Does the o.p. have a four wqire plug?...
Showing results 1 to 25 of 295
Page 1 of 12
1
2
3
11
>
Last
»
FOLLOW US ON
All Sponsors:
IMPERIAL BLADES
DumpsterSpot.com
Newest Threads
One Word Game
Hallway header options where door is
Carrier AC Outside Fan Will Not Turn ON
Granite Installed - Possible Issue?
Install Quarter Round when there is large gap underneath the baseboard?
Req opinions on professionally completed drain repair.
Hall Way Door - Is this load bearing?
Need some help
Pavers in an enclosed patio
Lawnmower Question
Driveway Resurfacing
Shower faucet leaking when shower is on and replacing stem does not help
Macs
Kitchen flooring
sheetrock and plaster question
How do I fill in a Koi Pond?