Old 11-13-2017, 06:40 PM  
ashtonallen
Junior Member
Join Date: Jan 2017
Posts: 14
Liked 1 Times on 1 Posts
Likes Given: 7

Default Running Romex Into Attic

I'm planning to add an outlet for my wall mounted TV. The source outlet is about 3 studs away from where I want to put the new outlet. To avoid having to repair drywall caused by running romex across the studs, I would like to drill a hole in the wall header, run romex from the source outlet straight up into the attic, run it along the header across 3 studs, then drop it back down through a drilled hole in the header to the new outlet. I live in Wilmington, NC and wonder if there would be any code problems with doing this? Also, does anyone have a suggestion how to affix the romex to the header?


ashtonallen is offline  
 
Reply With Quote
Old 11-14-2017, 01:26 AM  
joecaption
Senior Member
Join Date: Jan 2011
Location: Hartfield VA, VA
Posts: 1,944
Liked 247 Times on 195 Posts
Likes Given: 60

Default

Header?
A header is what's over windows and doors to support the roof.
Guessing you mean the top plate.
That's what sits on the top of walls.
Studs sit vertical inside the wall, so I have to guess you really mean the joist in the attic.
If I was going to do it I would drill 1/2" holes with a spade bit through the middle of the joist and run the wire though the holes instead of over them.


joecaption is offline  
 
Reply With Quote
Old 11-14-2017, 04:39 AM  
ashtonallen
Junior Member
Join Date: Jan 2017
Posts: 14
Liked 1 Times on 1 Posts
Likes Given: 7

Default

Thank you for the help with terminology. Just to make sure I’m clear. You would go to the edge of the joist and drill a long hole in the center the length of the several studs?
ashtonallen is offline  
 
Reply With Quote
Old 11-14-2017, 06:44 AM  
afjes_2016
Established Member
Join Date: Aug 2016
Location: , Northeast PA - USA
Posts: 252
Liked 112 Times on 92 Posts
Likes Given: 106

Default

What I do sometimes especially if the wall is an outside wall and fishing romex in an insulated wall can be quite tricky if not impossible at times.

A less labor intensive suggestion of course is if you have basement with access. Go down into basement and then back up again three studs over.

And if that is too much trouble you may want to consider taking off the trim where the floor and wall meet. Cut the sheet rock only high enough from the floor level up so it does not extend past the top of where the floor molding will be. Once you cut a strip of sheet rock then drill holes thru the studs. Run your romex thru those holes in the studs. Place a nail guard over each stud that you drilled (reason being sometimes it is difficult to get the drill in there and make the hold far enough back in the stud so a sheet rock screw does not puncher it or a nail from the floor molding. Put your floor molding back against the wall and secure it. Done. No need to replace the sheet rock you cut out because the floor molding is high enough to cover the cut out portion. But I would at least put spacer between the floor molding and the stud where you cut out the sheet rock to take up the difference in depth of the wall so the floor molding does not bow inward because of the void now.

Note be cautious of box fill calculations of the box you are tapping into. What size box it is and how many romexes are there now?
__________________

To the OP (O.riginal P.oster to this thread/topic).

If at any time you do not feel confident enough to perform a trouble shooting method that I suggest or feel you may not have the experience or comfort level to do so please ask questions before proceeding.
Electricity is dangerous and if not handled properly can cause serious injury or worse!
afjes_2016 is offline  
 
Reply With Quote
Old 11-14-2017, 07:32 AM  
bud16415
Fixer Upper
HRT_ADMIN.png
 
bud16415's Avatar
Join Date: Feb 2013
Location: Erie Pa, Pa
Posts: 4,323
Liked 1435 Times on 1099 Posts
Likes Given: 774

Default

Up and over or down and over or straight over. Makes no difference in code. If the attic is just a unfinished space with insulation showing and I went that way I would just use what is called a cable staple to secure the wire to whatever wood framing is there.

I personally like afjes_2016 method with removing the baseboard. Be careful drilling the holes because the bottom of the studs will have nails coming up thru them.

The steel plates mentioned are used to keep a future nail from going thru a wire. They are used when the wire is close to the surface. So in the baseboard method if you can’t get your drill back in far enough and you just notch the face of the stud for the wire you will want to put the protective steel plates where the wire is close to the surface. Not that anyone is likely to hang a picture at floor level but someone could re-nail the trim I guess

If your walls are just painted without texture cutting a slot in the drywall and repairing it is not a big deal also. If your walls have a texture or some covering then it gets a little harder. I always keep a few pieces of drywall scraps around to make patches out of. They do sell smaller pieces you can manage in your car for just about the price of a full sheet.

There is one other method and that is to use surface mounted track to incase the wires with a snap on cover. Not only will that hold your power cord it will hold all the other inputs going to the TV from your equipment rack. Keeps it all neat and tidy and when you need to add a cable you don’t have to rip the house apart again.
bud16415 is online now  
tuffy Likes This 
Reply With Quote
Old 11-14-2017, 07:44 AM  
bud16415
Fixer Upper
HRT_ADMIN.png
 
bud16415's Avatar
Join Date: Feb 2013
Location: Erie Pa, Pa
Posts: 4,323
Liked 1435 Times on 1099 Posts
Likes Given: 774

Default

I didnít mention in the last post another common option and one I have used in my own home theater. We all know what an outlet is but they also make a box called an inlet. And you can buy the whole deal called a power bridge. Here is a link.

https://www.amazon.com/dp/B00GWGZKF6...a-307437706068

This would all be installed in the one stud cavity and near the floor would be the inlet. From the inlet you would just then run the patch cord over to your outlet you plan on tapping into. One reason I use a power bridge is I have my electronics powered off a battery backup power conditioner and I plug that into an outlet and then run out of that to the inlet. The power bridge also provides passage for cables and such.

Now you have 5 or 6 options to think about.
bud16415 is online now  
 
Reply With Quote
Old 11-14-2017, 08:11 AM  
Snoonyb
Senior Member
Join Date: Sep 2006
Posts: 2,420
Liked 423 Times on 375 Posts
Likes Given: 1

Default

Also, there is a good chance that after drilling the double top plates above the stud bay of the existing recp., there will be a fire block that need to be drilled through. So, rather than the additional expense of a flex bit, there is a flexible fiberglass rod for locating obstructions within wall cavities, and you may have to use it either going up or down.

Instead of drilling the ceiling joists, nail a 1x4 across the span an staple the romex beside it, on either side.
__________________
Illigitimas non-carborundum
Snoonyb is offline  
 
Reply With Quote
Old 11-14-2017, 08:59 AM  
Sparky617
Member
Join Date: Nov 2014
Location: Cary (Raleigh), NC
Posts: 760
Liked 257 Times on 205 Posts
Likes Given: 159

Default

I used one of the inlet boxes that bud talks about. One challenge is I get a 60 cycle hum on my subwoofer when I use that line. If you use the power inlet make sure you have plenty of separation between your audio/video cables and the 120VAC power cable.
Sparky617 is offline  
 
Reply With Quote
Old 11-14-2017, 02:29 PM  
mabloodhound
Restoration & Renovations
Join Date: Jun 2008
Location: Halifax, MA
Posts: 98
Liked 22 Times on 17 Posts
Likes Given: 18

Default

Drilling the top plate is a good idea and will work. KISS principal applies
mabloodhound is offline  
 
Reply With Quote
Old 11-14-2017, 02:46 PM  
bud16415
Fixer Upper
HRT_ADMIN.png
 
bud16415's Avatar
Join Date: Feb 2013
Location: Erie Pa, Pa
Posts: 4,323
Liked 1435 Times on 1099 Posts
Likes Given: 774

Default

Quote:
Originally Posted by Sparky617 View Post
I used one of the inlet boxes that bud talks about. One challenge is I get a 60 cycle hum on my subwoofer when I use that line. If you use the power inlet make sure you have plenty of separation between your audio/video cables and the 120VAC power cable.
They used to be made to take regular romex between the inlet and the outlet. Now I see they have a special cable that Iím sure is code compliant. I wonder if they are using some shielding in there now.

I have never had any trouble with picking up 60hz hum I wonder if it is because I have the power conditioner inline.


bud16415 is online now  
 
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off


Similar Threads
Thread Thread Starter DIY Home Repair Forum Replies Last Post
Romex under raised foundation help please remout Electrical and Wiring 10 10-18-2015 06:00 AM
12/2 Romex or 14/2 Romex for Recessed Can Lighting? savatreatabvr Electrical and Wiring 24 01-18-2014 06:15 PM
Help wire running wire thru Attic.... Rockrz Electrical and Wiring 21 05-14-2013 06:31 PM
Nm-b romex run outdoors alexb5647 Electrical and Wiring 24 03-11-2013 10:17 AM
Romex Routing in Attic 69-er Electrical and Wiring 3 02-19-2007 03:40 PM



Newest Threads