  1. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    Tom, just want to be clear here. There is a meter with 200 amp breaker and ground rod. Then there are 3 wires to house with square d 200...

    Dec 9, 2018 at 9:01 PM
  2. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    I will also make those changes in the subpanel connected to the main. Mark neutral, use large lug. Anything else? When we are done with...

    Dec 8, 2018 at 1:10 AM
  3. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    Sorry just saw your reply.

    Dec 8, 2018 at 1:02 AM
  4. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    So, the only thing that needs to be done in this box is use large lug for the bare stranded wire, but leave on neutral buss bar?

    Dec 8, 2018 at 1:01 AM
  5. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    There are only 3 wires for both buildings. There is a rod at meter, house and garage. Sorry, thought I indirectly answered that.

    Dec 7, 2018 at 2:57 PM
  6. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    I definitely appreciate the help! Honestly my head is hurting...……………..Thanks

    Dec 7, 2018 at 4:36 AM
  7. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    Dec 7, 2018 at 4:34 AM
  8. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    Yes, that wire needs to be moved to ground bar instead of the neutral bar. That goes to a ground rod, not from house. Does that neutral...

    Dec 7, 2018 at 4:25 AM
  9. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    Yes, that bare wire is the grounding rod for supply. Need to use bonding screw for that panel?

    Dec 7, 2018 at 4:22 AM
  10. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    Tank is in the same room as the house main panel. The breaker is in this panel. The detached garage is not even close to that meter and...

    Dec 7, 2018 at 4:14 AM
  11. js5518 attached a file to the thread Bonding screw main panel/ grounded neutral.

    detached garage[ATTACH]

    20181205_163847_1544115571954_resized.jpg Dec 6, 2018 at 5:11 PM
  12. js5518 attached a file to the thread Bonding screw main panel/ grounded neutral.

    sub inside next to main attached with conduit[ATTACH]

    20181206_103217_1544115564859_resized.jpg Dec 6, 2018 at 5:10 PM
  13. js5518 attached a file to the thread Bonding screw main panel/ grounded neutral.

    main inside[ATTACH]

    20181206_103144_1544115566731_resized.jpg Dec 6, 2018 at 5:09 PM
  14. js5518 attached a file to the thread Bonding screw main panel/ grounded neutral.

    Outside. [ATTACH]

    20181206_102443_1544115569193_resized.jpg Dec 6, 2018 at 5:08 PM
  15. js5518 replied to the thread Bonding screw main panel/ grounded neutral.

    So, you would consider the outside 200 amp breaker as the main? This is where it should be bonded and everything after is separated ?...

    Dec 6, 2018 at 3:51 PM