Water Supply Connection for House and Irrigation

House Repair Talk

Help Support House Repair Talk:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.

jasontf

New Member
Joined
Jun 2, 2011
Messages
2
Reaction score
0
I'm installing an irrigation system and I need to replace the tee that goes into my house to use one side for my sprinklers (instead of an existing hose bib). The existing installation is 3/4" copper pipe (from the meter) to a compression fitting, then the main shutoff 1", then a galvanized union 1", then the tee into the house and hose bib. After the tee, I'll have a pressure vacuum breaker, then SCH 40 PVC to the irrigation valves.

When I replace the tee, must I use galvanized again? I would prefer pvc with threaded connections (SCH 80?), but this is above ground. If I wrap it in pipe insulation and electrical tape, will it be to code? This is PVC after the main house shutoff just outside the structure.
 
Depends on if it gets cold there. If so i would not reccomend using pvc you can use a product called pex. PEX Information

This is the best product on the market, if you use this buy the crimper that uses stainless steel crimp rings. Available at home depot or lowes.

If weather is not an issue the pvc is just fine. Use schedule 80
 
Both PEX and PVC need to be shielded from UV light...

PEX more so...
 
Although pex is not designed for outdoor use you can always wrap in and insulation or bury a few inches down.
 