  1. maxdad118

    No heat! Bad control?

    Problem resolved, bad gas control. $76 on Amazon and about 20 minutes to swap it out
  2. maxdad118

    No heat! Bad control?

    Flame sensor needs a flame and I don’t have an opening gas control to get a flame
  3. maxdad118

    No heat! Bad control?

    Video
  4. maxdad118

    No heat! Bad control?

    Hello, my Goodman faf stopped heating. I’m getting 24+ Volts at control and vac switch checked ok. What do you think? It’s about 10 years old.
  5. maxdad118

    LG LRG3095ST/02 gas range F11 heat error, temperature sensor, ignitor, control board, or something else

    I bet it does, try it! You won’t hurt anything. There should be a part number on the igniter itself. Norton is usually the brand or make. Also it does not matter the wire configuration.
  6. maxdad118

    LG LRG3095ST/02 gas range F11 heat error, temperature sensor, ignitor, control board, or something else

    The reason the broiler igniter hasn’t failed yet is because it seldom used compared to the oven.
  7. maxdad118

    LG LRG3095ST/02 gas range F11 heat error, temperature sensor, ignitor, control board, or something else

    Does the broiler share this igniter or do you have separate burners for both? If separate and you said the broiler works I’m betting the oven igniter is bad. The igniter could still glow but be weak, the valve needs xxx amount of micro amps to open- try swapping that out, be careful not to break...
  8. maxdad118

    Ruud Furnace is making buzzing noise while furnace filter is inside unit

    My mistake, I didn’t even realize there was a video? Ignore my reply. Lol.
  9. maxdad118

    Ruud Furnace is making buzzing noise while furnace filter is inside unit

    Sound of the transformer probably, get a cheapie stethoscope from harbor freight and probe around, just be careful not to short anything out. Put the end on the housing of the components.
  10. maxdad118

    Random malfunction on Rheem furnace.

    How are the vacuum hoses going to the inducer switches? If they don’t close I don’t think you will get 24v at the control. Have you pulled them off to check for any cracks?
  11. maxdad118

    Random malfunction on Rheem furnace.

    That looks like a place for a ground.
  12. maxdad118

    Random malfunction on Rheem furnace.

    15v is an odd number? Xformers are usually 120/24v? Seems like a weird number to me..
  13. maxdad118

    Random malfunction on Rheem furnace.

    It could have a spark that lights a pilot, like the 3-wire flame switch type
  14. maxdad118

    Random malfunction on Rheem furnace.

    I don’t think it’s a bad board, gas control. Maybe try checking for bad/loose connections. I do a fair amount of furnace troubleshooting in my line of work, although I’m not a licensed hvac contractor. It’s intermittent and random, it appears, correct? Was the pilot actually cleaned? Do you have...
  15. maxdad118

    Using rafter ties as base for storage in 1950’s house

    So my question is this, a lot of these were added to make a bedroom in the garage. I can make out a few of the originals but was is there a ‘rule of thumb’ for the distance between them or quantity of them? I’ve seen other homes of this vintage and they don’t have nearly as many. I’d like to...
  16. maxdad118

    Using rafter ties as base for storage in 1950’s house

    Pardon the chicken scratch but when you say ‘notch’ are you referring to the lower pic? I was thinking of doing the upper pic. Which makes more sense
  17. maxdad118

    Using rafter ties as base for storage in 1950’s house

    That was my original plan but wanted expertise on this. I still have a bit of work to do before I get to this, more sheet rock to remove, moving stuff around to minimize the mess, lol.
  18. maxdad118

    Using rafter ties as base for storage in 1950’s house

    Ok thank you, though my roof rafters are only 2x4, can I use 2x6 ties(notched to fit onto top plate of wall)?
  19. maxdad118

    Using rafter ties as base for storage in 1950’s house

    I’m getting my garage back, it was once a bedroom. I have removed the wall and some of the sheet rock with plans to add more outlets, insulation and new sheet rock. I’m wanting to swap out the 2x4 rafter ties for maybe 2x6(?) for strength. Not sure if it’s needed but want to add some plywood...