  1. V

    CEILING TILE REPAIR/INSTALL (pics)

    Removing the staples is another headache. If i had one of them multitools i could cut them flush…someone used really long double staples so it is a real pain without disturbing what hasnt fallen yet. I saw this video and it seems like the easiest th8ng to do a,d buy some liquid paper to hide the...
  2. V

    CEILING TILE REPAIR/INSTALL (pics)

    Visiting my inlaws and they had a leak last year. Insurance paid for repair. There was some residual moisture in the ceiling and a section of tiles just fell. They are a kind of tongue and groove and it looks like the installers used 1/2-3/4” narrow crown staples(?) to attach the tiles in the...
  3. V

    what is this kind of ceiling called and can only a portion of it be fixed?

    I was just getting ready to create a post on a very similar situation. CEILING TILE REPAIR/INSTALL.
  4. V

    Mnpt copper on brass

    Channel locks broke these free.... I think channel locks were the only tools that would bite into the copper for secure purchase.
  5. V

    Mnpt copper on brass

    Okay...when I get back I will try and turn these that way.... what a headache. The smallest things prevent a project to COMPLETION,. THANK YOU
  6. V

    Mnpt copper on brass

    I have already cut the pipe. I know they aren't suppose to be sweated but was wondering if people sometimes do stupid stuff. Who knows. The pictures are upside down. I put a wrench to it and they wont move. Pipe wrench? Any ideas?
  7. V

    Mnpt copper on brass

    These were leaking for so long. I stopped the lead but now have to remove the old copper from this brass diverter. do you think they are sweated ? pipe wrench a little heat? Images are upside down.
  8. V

    General Electric A1g48t waffle iron

    When i saw that, i wanted no part of a half assed vintage Repair I would make and had to post here... Thank you.
  9. V

    General Electric A1g48t waffle iron

    That is exactly what the repair shop said, about build quality. I think i will do what you said and make a 12-14ga short extension cord. Big thank you. BTW, what is that clip or attachment for the power cord Anyway?
  10. V

    General Electric A1g48t waffle iron

    I‘ve had this waffle iron as long as I can remember and we use it now for a sandwich press... The power cord got damaged at some point and it was taped. The thing works just fine except the power cord gets warm and that means resistance and fire hazard. When i took it to my local appliance...
  11. V

    Verifying required box volume for welding circuit

    I am installing a 240v 40a welding circuit using 8-2 8awg romex and respectfully ask someone to please verify my box requirement below. The circuit will terminate in a plastic 18cu in box with a 50a/250v outlet. I calculate a volume of 15cu in. box requirement and is within this plastic box...
  12. V

    Alternative to ripping out drywall every time circuits are added to load center

    Man, as much as i searched this, i could not find the wealth of options from your link......big thanks....and access panel for my access panel
  13. V

    Alternative to ripping out drywall every time circuits are added to load center

    We have a 200 amp load center and everytime i have to add a circuit, pull some wire and anchor it through the side i have to cut out some drywall, do the install and repair the wall. Do they make a frame for the load panel that offers this kind of side panel access? thanks in advance
  14. V

    Reliance 310C transfer switch circuit not working

    310C transfer switch I installed a Reliance 310C transfer switch which has in the A&B position a double pole breaker which I replaced with (2) 20a breakers to use as separate circuits through the main load panel . BUT, when I replace these breakers, the A circuit, which powers the Frig...
  15. V

    SHARKBITE fittings for air line

    I am using the blue label copper I think "L" copper....none of my lines will be pressurized beyond 90 psi...thanks for the heads up !
  16. V

    SHARKBITE fittings for air line

    So what are you referring to ? Or do you mean just out of the blue with nothing in particular or specifically anecdotallike grass is green, sky is blue...
  17. V

    SHARKBITE fittings for air line

    ANother question: any pros or cons to using pipe dope over teflon tape for air fittings? thanks
  18. V

    SHARKBITE fittings for air line

    Thanks I have those specs. but has anyone here used them for this application.
  19. V

    SHARKBITE fittings for air line

    I am finishing up the preproduction elements of my project and have an issue that can be resolved with SHARKBITE coupler for 1/2" copper on my air line. Has anyone used sharkbites for air? thanks
  20. V

    Will oil pool in this hose?

    Yeah, thanks for that , but as I recall, the green oxidation is a reaction between the excess flux that remains and not a result of using copper tubing. I will use only as much as I need to get the job done!