  1. J

    Furnace leak

    Replace furnace
  2. J

    1 Zone not heating

    Damper motor for that zone could be bad or thermostat for that zone could be bad
  3. J

    Ancient furnace motor won't start

    Rescue motors don't come with capacitors. You have to buy it seperatley it should say on the motor box what size cap the motor will need two brown wires
  4. J

    York stellar furnace acting up

    Replacing the flame sensor won't fix your problem. Does your furnace have a circuit board? Does the gas valve have 24 volts across it as it drops out if so replace valve. If 24 volts drops out as flame drops out replace control board. Make sure rollout switches aren't opening.
  5. J

    Gas supply shuts off early

    Make sure flame sensor is also clean/polished with some sand paper until shiny chrome
  6. J

    wiring connections on a Robert Shaw standing pilot gas valve?

    It doesn't matter if its just two wires either way will work the same
  7. J

    Air handler blower motor

    Sounds like a relay in the circuit board is going out might need to replace board
  8. J

    Request for solution to the hot second floor, cold basement challenge.

    Do you only have one thermostat either upstairs or down. If so you might want to look into a zoning system where a thermostat would be added so you would have both floors controlled by dampers in the ducts. Can be kinda expensive but it would solve your problem