Found out what was blowing fuse in this dryer at least the problem.
After checking all wiring etc like you guys advised found no problem.
Here is what I found out,
When my grandson did the drying ,he could do up to ten loads no prob.
When his wife dried it blew fuse.
Believe it or...
Thank you Blue jay and Nestor
yes I am care full around all voltages and would pull dryer plug before I check for frayed wires.
Let me explain a little further 100 amp service to square d to main panel
This main panel has fuses,and old one 14 circuits or so,not enough to have proper...
re
checked voltage drop with dryer at high (Full of clothes) from panel to dryer,About 3 volts 238-241.
With amp probe on black lead 20-22 amps.
wire seems fine no change in voltage or current even when all other appliances on.
Did find a loose wire in box that shuts power of to dryer...
Hi
My Kenmore electric dryer app.five years old blows 30 amp fuse after it runs for half hour.works great till it gets hot,then fuse blows.Ffuses are tight and no bad connections in box .Could defective t-sat cause this.