DIY Home Repair Forum: HVAC 11-17-2008, 07:38 AM
Replies: 24
Views: 18,198
Posted By rodge
Unit continues to work fine, tested by temps in...

Unit continues to work fine, tested by temps in the 20-s at night couple of times.
York part # for FLAME ROLLOUT switch pictured in post #12 is 025-26908-000 and I bought it real cheap here...
DIY Home Repair Forum: HVAC 11-11-2008, 10:07 AM
Replies: 24
Views: 18,198
Posted By rodge
Works for now(fingers crossed).

Works for now(fingers crossed).
Turned out inducer blower was working, but not good enough to close the pressure switch.
Removed inducer blower, vacuumed inside, rotated fan manually.
Removed flue...
DIY Home Repair Forum: HVAC 11-09-2008, 12:44 PM
Replies: 24
Views: 18,198
Posted By rodge
Some history: At the end of last heating season...

Some history:
At the end of last heating season this unit would ignite burners and after a short while the flame would go out.
I left it at that till new season, and when decided to take a look...
DIY Home Repair Forum: HVAC 11-09-2008, 08:07 AM
Replies: 24
Views: 18,198
Posted By rodge
You helped a lot and it's much appreciated ,...

You helped a lot and it's much appreciated , especially as problem still stands.
I was just distracted by other things.

Bought 320F switch. Using it temporary to fix this unit. If fixed, Iíll...
DIY Home Repair Forum: HVAC 11-04-2008, 03:50 PM
Replies: 24
Views: 18,198
Posted By rodge
the switch/fuse has no continuity, needs to be...

the switch/fuse has no continuity, needs to be replaced.
I searched for exact same one, found info but no place to buy it.
It opens at 152 degrees C or 306 F.
I think it was not supposed to be...
DIY Home Repair Forum: HVAC 11-04-2008, 08:16 AM
Replies: 24
Views: 18,198
Posted By rodge
Problem solved for now!

You were right on!
The switch! First I didn’t see anything in the burn chamber, then looked in our main unit York Diamond 80 and saw the cylinder switch!
In this small broken unit same wires just...
DIY Home Repair Forum: HVAC 11-03-2008, 12:18 PM
Replies: 24
Views: 18,198
Posted By rodge
sure feels like something stupid (disconnected...

sure feels like something stupid (disconnected wire), before the pressure switches.
Found troubleshotting manual for control...
DIY Home Repair Forum: HVAC 11-02-2008, 08:25 AM
Replies: 24
Views: 18,198
Posted By rodge
There is what I suspect is a limit switch, round...

There is what I suspect is a limit switch, round with 3 tabs, has too many wires connected, how to check it ?
Checked pipes – clean.
This unit is heating/cooling and cooling is fine, I had to say...
DIY Home Repair Forum: HVAC 11-01-2008, 03:31 PM
Replies: 24
Views: 18,198
Posted By rodge
Gas is on; blue switch inside and red outside. ...

Gas is on; blue switch inside and red outside.
Pressure switches not connected with each other.
LEFT one(with 3 wires) connected by tube to inducer motor.
Tube from the RIGHT switch(with 2...
DIY Home Repair Forum: HVAC 11-01-2008, 08:55 AM
Replies: 24
Views: 18,198
Posted By rodge
Ignator looks like this ...

Ignator looks like this
http://www.theignitorstore.com/thumbnail/product/64297/640/480

If electronic means no pilot light, then it's electronic.
Normally it should glow, but does nothing....
DIY Home Repair Forum: HVAC 11-01-2008, 06:55 AM
Replies: 24
Views: 18,198
Posted By rodge
York Stellar Plus wonít ignite

Natural gas furnace, 12 years old, small, only heats 2 rooms,
Sticker says model # M3UF024SA for cooling, P2UDD06N03B01D for furnace, can’t find it anywhere.
Situation:
When heat is switched on...
Showing results 1 to 11 of 11