DIY Home Repair Forum: HVAC 04-12-2012, 12:11 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
The blower was actually shot. It did not run up...

The blower was actually shot. It did not run up to speed. I replaced the furnace.
DIY Home Repair Forum: HVAC 01-02-2009, 04:15 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
more stuff

blower looks OK. One speed stinks when it runs (smells burned) but it does run. So I think the motor is shot and there is something else amiss (since the speed that is "burned" never gets to run...
DIY Home Repair Forum: HVAC 12-23-2008, 11:10 PM
Replies: 23
Views: 7,988
Posted By johnceberhardt
P.S. my old carrier weathermaker hasn't failed at...

P.S. my old carrier weathermaker hasn't failed at all. I think i'll go give it a hug.
DIY Home Repair Forum: HVAC 12-23-2008, 11:07 PM
Replies: 23
Views: 7,988
Posted By johnceberhardt
Mine does the same thing. Look at the pictures in...

Mine does the same thing. Look at the pictures in my thread. Little blower always runs, igniter wire glows, ignites gas (nice flames), runs about 5 minutes, heats up the limit switch until it exceeds...
DIY Home Repair Forum: HVAC 12-22-2008, 11:58 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Just an FYI: In the mean time (York still close...

Just an FYI: In the mean time (York still close to dead) my Trane XE80 failed again over at the condo. LED on the control board flashes 4 times indicating a Hi Limit switch open. 3 hi limit switches...
DIY Home Repair Forum: HVAC 12-22-2008, 10:45 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
cleaned the trap still won't run

cleaned the trap still won't run
DIY Home Repair Forum: HVAC 12-16-2008, 10:14 AM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Drainage?

You mean your furnace caught a "cold" and had drainage problems? -WOW!

I never noticed a gurgle but that doesn't mean it's not the problem. I had the thing off when I disassembled and cleaned up...
DIY Home Repair Forum: HVAC 12-11-2008, 12:39 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Hi Brian, I appreciate the advice. That is...

Hi Brian,

I appreciate the advice. That is possible since I have not yet pulled apart the entire blower assembly. I will rip it apart next week and let you know. I have a cap tester but haven't...
DIY Home Repair Forum: HVAC 12-07-2008, 08:12 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Schematic and vent motor

Here is the latest strange thing that explains the latest twist of randomness. The vent motor was overheating and shutting the system down. It never got a chance to cool off because it never gets a...
DIY Home Repair Forum: HVAC 12-07-2008, 07:47 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Relays are random

I know it doesn't make any sense. Right now its relays are kicking off and on almost at random (very cold outside) , sometimes ignites and sometimes not. It will run for only a minute at a time-...
DIY Home Repair Forum: HVAC 12-06-2008, 06:44 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
During normal operations I only measured 70 volts...

During normal operations I only measured 70 volts at the black wire relay connection when activated (this is a 115-120 volt blower, right?). I connected the black wire up to 120 volts straight into a...
DIY Home Repair Forum: HVAC 12-06-2008, 12:49 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Hi Glenn, It not only thickens but it freezes!...

Hi Glenn,
It not only thickens but it freezes! I didn't get to it yesterday (work gets in the way) but the back half of the house maintained 63* all night despite the 6* temp outside. The old york...
DIY Home Repair Forum: HVAC 12-04-2008, 03:14 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Hi Glenn, After I test the blower I'll...

Hi Glenn,

After I test the blower I'll check out the relays. Relays are usually cheaper than blowers so I hope that's where the problem it. When I first cracked the case open I found lots of...
DIY Home Repair Forum: HVAC 12-04-2008, 10:02 AM
Replies: 24
Views: 15,780
Posted By johnceberhardt
plug wiring

I'll do this on Thursday or Friday. On my PSC motor the black is high speed and the red is low (according to the schematic and the red wire is currently not and has never been connected to anything).
DIY Home Repair Forum: HVAC 12-03-2008, 06:15 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Already did all that. It has a new filter and I...

Already did all that. It has a new filter and I removed the ducts to let it run wide open. The limit switch still slowly rotates until it hits the upper limit and shuts down (then repeats the cycle)....
DIY Home Repair Forum: HVAC 12-02-2008, 09:15 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Update

Still failing because I haven't worked on it yet. Heats a little and then resets. Here are some pictures.

Wires to blower are red-low (not connected), blue-med, black-hi, two browns and a white....
DIY Home Repair Forum: HVAC 11-30-2008, 02:17 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
Hi Glenn and kok328, No, unfortunately...

Hi Glenn and kok328,

No, unfortunately there is nothing in series that I’ve seen so far. The fan limit thermostat unit is a one-piece part that has a probe that extends into the firebox. There is...
DIY Home Repair Forum: HVAC 11-29-2008, 01:11 PM
Replies: 24
Views: 15,780
Posted By johnceberhardt
York Stellar Plus NG furnace wont' stay running-HELP

York Stellar Plus Natural gas furnace, I bought the house about five years ago so I donít know exactly how old it is. It is small; only heats back half of house and that consists of only a few rooms....
DIY Home Repair Forum: HVAC 11-28-2008, 11:24 AM
Replies: 24
Views: 18,197
Posted By johnceberhardt
Rodge and kok328, I have a similar furnace that...

Rodge and kok328, I have a similar furnace that just began to fail recently. It starts to run the burners ignite and preheat the vents. The fan limit control rotates as the temperature rises and...
Showing results 1 to 19 of 19