  1. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    The blower was actually shot. It did not run up to speed. I replaced the furnace.
  2. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    blower looks OK. One speed stinks when it runs (smells burned) but it does run. So I think the motor is shot and there is something else amiss (since the speed that is "burned" never gets to run unless i hold or keep the limit switch from cutting off the gas before it gets to run the faster...
  3. johnceberhardt

    York Stellar Erratic Starting

    P.S. my old carrier weathermaker hasn't failed at all. I think i'll go give it a hug.
  4. johnceberhardt

    York Stellar Erratic Starting

    Mine does the same thing. Look at the pictures in my thread. Little blower always runs, igniter wire glows, ignites gas (nice flames), runs about 5 minutes, heats up the limit switch until it exceeds 200* and shuts the gas valve down-restarts cycle. I think it's the blower motor but i haven't...
  5. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    Just an FYI: In the mean time (York still close to dead) my Trane XE80 failed again over at the condo. LED on the control board flashes 4 times indicating a Hi Limit switch open. 3 hi limit switches are all connected in series with yellow wires. Blower comes on but it will never set the igniter...
  6. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    cleaned the trap still won't run
  7. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    You mean your furnace caught a "cold" and had drainage problems? -WOW! I never noticed a gurgle but that doesn't mean it's not the problem. I had the thing off when I disassembled and cleaned up all the parts near the blower but never checked that for a clog. I had a carrier that shut down...
  8. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    Hi Brian, I appreciate the advice. That is possible since I have not yet pulled apart the entire blower assembly. I will rip it apart next week and let you know. I have a cap tester but haven't used it since most caps in the past have blown open or shorted out (and catastrophe for some other...
  9. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    Here is the latest strange thing that explains the latest twist of randomness. The vent motor was overheating and shutting the system down. It never got a chance to cool off because it never gets a break. I have a fan on it now and it is back to "normal" fail mode. At least this was logical...
  10. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    I know it doesn't make any sense. Right now its relays are kicking off and on almost at random (very cold outside) , sometimes ignites and sometimes not. It will run for only a minute at a time- getting worse. When it does run ands gets the flame lit, it shuts down right when the blower relay...
  11. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    During normal operations I only measured 70 volts at the black wire relay connection when activated (this is a 115-120 volt blower, right?). I connected the black wire up to 120 volts straight into a socket using a plug wire set and the blower seemed to work fine (it didn’t blow up or...
  12. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    Hi Glenn, It not only thickens but it freezes! I didn't get to it yesterday (work gets in the way) but the back half of the house maintained 63* all night despite the 6* temp outside. The old york kicked on and off all night long. Tonight we'll be lucky if it stays above zero. Right now it's a...
  13. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    Hi Glenn, After I test the blower I'll check out the relays. Relays are usually cheaper than blowers so I hope that's where the problem it. When I first cracked the case open I found lots of leaky hoses dripping water into the control box (and on the relays). I squirted some WD40 on them but...
  14. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    I'll do this on Thursday or Friday. On my PSC motor the black is high speed and the red is low (according to the schematic and the red wire is currently not and has never been connected to anything).
  15. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    Already did all that. It has a new filter and I removed the ducts to let it run wide open. The limit switch still slowly rotates until it hits the upper limit and shuts down (then repeats the cycle). The airflow is medium, it never goes to high speed. The airflow is probably not good enough to...
  16. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    Still failing because I haven't worked on it yet. Heats a little and then resets. Here are some pictures. Wires to blower are red-low (not connected), blue-med, black-hi, two browns and a white. Browns are connected to (through) what looks like a giant capacitor. Can't see the ground wire...
  17. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    Hi Glenn and kok328, No, unfortunately there is nothing in series that I’ve seen so far. The fan limit thermostat unit is a one-piece part that has a probe that extends into the firebox. There is a dial on it that rotates as it heats up. There are set tabs on it. The installer/consumer...
  18. johnceberhardt

    York Stellar Plus NG furnace wont' stay running-HELP

    York Stellar Plus Natural gas furnace, I bought the house about five years ago so I don’t know exactly how old it is. It is small; only heats back half of house and that consists of only a few rooms. Sticker says model # P1UDD06N03801A York Stellar Plus Natural gas furnace for furnace...
  19. johnceberhardt

    York Stellar Plus won’t ignite

    Rodge and kok328, I have a similar furnace that just began to fail recently. It starts to run the burners ignite and preheat the vents. The fan limit control rotates as the temperature rises and the blower motor kicks in. Very soon after this, it shuts down and repeats the cycle. Rodge, it...