  1. N

    condensation troubles

    like kok328 said, did you look inside the air handler where the evaporator coil is to check that the pan is relatively empty while it is running? the drain my be fine but the unit could be collecting water in the pan due to a leveling problem. usually there is an access panel you have to take...
  2. N

    hvac

    is it a 3-speed motor? can you post a picture of the motor that shows how you have it wired up? usually with a 3-speed motor you have black, blue and red wires for speeds (hi, medium and low), you have two orange wires connected together, two yellow wires connected together, a brown and brown...
  3. N

    which coil should i use?

    i live in texas, and don't ask me why, but all the houses around here have gas furnaces. really, it makes no sense considering i grew up in PA where we had a heat pump. go figure. in any case, i have two units in the attic and both had old horizontal A coils to start with, however i'm...
  4. N

    AC problem diagnosis

    i'm no expert, but i had a similar problem awhile back. neither the fan nor the compressor would turn on because the capacitor was shot. replaced the capacitor for like $12 and it was good to go.