  1. J

    GFI Issue?

    the load side of the GFCI outlet went to a junction box. From the junction box one wire went to 1 outlet and another wire went to 3 outlets and the 2 wall sconces. The loose neutral was the first of the 3 outlets in a string. Just so happened it was the LAST outlet I checked.
  2. J

    GFI Issue?

    thanks to all who provided input. I replaced the GFCI outlet and the same condition persisted. I pulled the outlets and switch out one by one and checked the connections. Found a loose neutral on, of course, the last outlet of the string.
  3. J

    GFI Issue?

    thanks all. i am going back to the RV today. I will check the existing outlets first for a compromised neutral. I have a new GFCI outlet that I bought to replace the existing one if the neutrals checkout OK.
  4. J

    GFI Issue?

    I have a circuit that has 3 outlets that work fine. Then there is a GFI Outlet which also works fine. There are four outlets and two small wall sconce lights that do not work. Using a plug tester (the little thing that plugs into a socket that has three lights) the 4 outlets say they are...