Recent content by Avant

House Repair Talk

Help Support House Repair Talk:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. A

    Gas Control Valve

    No worries. Just glad people are here to help. Next project is my 500Sq ft putting green in the back yard :)
  2. A

    Gas Control Valve

    Ok. I just fixed this stupid thing. Took the flame sensor out. Cleaned it. Then also disconnected the ignition module for a few minutes to clear the ingition lockout code. Plugged it all back and and BOOM. Works like a charm now! Thanks all for the help! Its working great now!
  3. A

    Gas Control Valve

    Found my fire place. FMIDVF36. Here is how it is wired.
  4. A

    Gas Control Valve

    Totally get what it does. Just don't see any place that it would plug/screw into on the gas valve or module.
  5. A

    Gas Control Valve

    House was built in 1997. Not sure the brand of fireplace. Found the Schematic. I am missing what looks like a ground from that "spark plug" back to the module But mine is wired like this.
  6. A

    Gas Control Valve

    Yea, this sensor only has the one 12v wire going to it. No other wire that goes back to the ignition module.
  7. A

    Gas Control Valve

    Ok uploaded with different client. Try now. post above this one should work.
  8. A

    Gas Control Valve

    Weird, I am uploading the pictures with google photos. Try them now.
  9. A

    Gas Control Valve

    The pictures are up. Not sure why you can't see them. It does not have a thermo coupling. It has a flame sensor. There is a Fenwal Ignition Control Module. When the switch is flipped to turn on the fireplace, the ignition module then gives power to the flame sensor/igniter as well as the...
  10. A

    Gas Control Valve

    Here are the images.
  11. A

    Gas Control Valve

    yea it has the wires hooked up. just measure resistance and it should be .7 or higher. ill do that today.
  12. A

    Gas Control Valve

    yea i dont have one anywhere. just that flame sensor.
  13. A

    Gas Control Valve

    The valve is a : 1/2" X 1/2" 24v Direct Spark Gas Valve (170,000 BTU) SKU: 722-051Brand: Robertshaw It ignites and flame goes for about 5 seconds then the lock out happens. The part that actually sparks (like a taser) has the electrode built on it. Looks like this.
  14. A

    Gas Control Valve

    So i got a new valve. it fires up but then shuts off after a few seconds. the ignition module sales "ignition lockout" I am guessing a bad electrode?
Back