  1. E

    Steam Boiler Replacement

    Paul, Sounds great. Thank you for your help it is greatly appreciated. Happy Thankgiving to you and your family. Lonnie.
  2. E

    Steam Boiler Replacement

    Correct. Each radiator has only one feed in. On my old boiler there is a large riser pipe coming out of the top and goes left that tees off to each radiator. Also a tee off this pipe that goes down and back to the bottom of the boiler. There is also a second large riser pipe that comes out...
  3. E

    Steam Boiler Replacement

    Paul, I took a couple of pics, let me know if you get them. The new boiler I have says SGO Series 3 Oil-fired natural draft steam boiler. My radiators have pipes only going in none going out with a vent on the other side.
  4. E

    Steam Boiler Replacement

    Well I would appreciate that. I haven't contacted the manufacturer yet they usually won't help the homeowner with such matters they'd say contact a professional. I purchased the boiler on ebay in a flood sale, had to replace the liner. Boiler is fine the box was ruined so they couldn't sell...
  5. E

    Steam Boiler Replacement

    My intent was not to insult Joe, I hope that's not what happened. I do appreciate the input but since I already have the new boiler it seemed like a mute point. Contacting the manufacturer is a good idea I will do that, I just thought somebody might be watching that could offer a simple...
  6. E

    Steam Boiler Replacement

    Many reasons. Cost for one, convenience is also a big factor. My steam boiler is down in the cellar and I would have to go down there everytime I wanted to put wood on it. Now I have a nice glass doored Lopi wood stove (looks good too) that is in my livingroom and the wood is handy just...
  7. E

    Steam Boiler Replacement

    I am currently in the process of replacing my 30 year old Oneida 110K BTU boiler with a new Weil-McLain SGO-3 114K. The only snag I see is the old boiler has two riser pipes and the new one only has a place for one. Everything else looks pretty straight forward. Any comments or suggestions...
  8. E

    Air Volume Control

    Thanks Blue Jay, I think I'll draw down some water in the tank and pump some air in there. My pump is quite old so when that dies someday I think I'll put on a new pump and get a tank with a bladder in it. As far as running the draw line back down the casing I'm a little afraid to undo it...
  9. E

    Air Volume Control

    It's a hand driven well and I had trouble years ago with the copper pipe that went inside the 1 1/2 inch well casing. It developed a small hole and we lost prime. We just hooked the suction line to the top of the well casing and it's worked fine since then. Is the mistake I made buying a...
  10. E

    Air Volume Control

    I have a shallow well (12 ft) with a GE 1/3 hp shallow well pump hooked to a 42 gallon epoxy lined (bladderless I think) water tank. It gets full of water and I have to almost completely drain it and then refill it frequently or else the pump comes on with any demand for water. What kind on AVC...
Back