Search results

House Repair Talk

Help Support House Repair Talk:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. T

    Any advice on installing service-mast (through-the-roof) and semi-flush meter/main?

    My current 200 AMP electrical service attaches to the rear of my single-family house's second-story roofline, and passes over a single story addition. During an electrical inspection, the city inspector recommended that the service be raised up since anyone walking on the addition roof (or...
  2. T

    Manual J Question - Number of occupants, multiple floors

    I'm doing a Manual J calculation (using version 7) for a two-story, with a finished basement, house. For the number of occupants (for sensible and latent heat gain), the example in the Manual J book specifies using one more person than the number of bedrooms in the house. But, my question...
  3. T

    Place DIY Basement Slab in Sections?

    So, like this? Then, remove the wood form, and you have the wire mesh hanging out, to be inserted into the next strip?
  4. T

    Place DIY Basement Slab in Sections?

    I had a few questions in regards to doing multiple pours for a basement floor (with rebar tying the sections together). 1. If you do multiple pours, do the 'joints' between the sections become natural crack lines? 2. When doing a new pour next to an existing cured section, what (if...
  5. T

    Has anyone else had a bad experience with web-based construction supply merchants?

    I'll go first... When is a cardboard box a case? I recently ordered construction window shims from, Mr. Shims. He sells a kit of shims that contains a variety of sizes and which is described as: 'Our assortment kits are enclosed in a heavy duty cardboard box. Inside are placed 100ea...
  6. T

    Rewiring old house question

    I would do the following: 1. Run a single 14-2 to master bedroom and run the overhead lights for the closet and bedroom on same circuit. 2. Run a single 14-2 to master bedroom and run to the receptacles 3. Run a single 14-2 to second bedroom and run the overhead lights for the closet...
  7. T

    Installation of Tuff-R sheet foam - in-cavity/out cavity?

    am redoing the plaster walls in a room in my house in New York (I am also opening up the wall cavities to redo the electrical wiring). I don't expect to find any insulation in my 2x4 walls (house built in the 1920's). I was thinking about furring out the walls to a true 2 x 6", then cutting...
Back
Top