Yes you could install a motorized damper. It likely wouldnt be a simple install as you'd need access to around the wall near that diffuser/grille. There may not be enough physical space for moto-damper in the existing wall, so you'd need to expand the wall or add a bulkhead. Also, you would need...
Appears you have an erv of some sort. Where is the central unit located? That round diffuser is connected behind the wall to some ductwork, trace out where the ductwork goes and you'll eventually find a unit with a fan in it, from there you can plan on re-wiring a...
I think that boot needs dimensions written on it, before we can make assumptions on if it'd fit. I am able to get all sorts of sizes of oval, as I'm currently working with 42/20, 44/22 and 16/8.
YOu can add self-tapping sheet metal screws to the s-cleats about 2" in from either end, keep in mind you are going through about 5 layers of tin. This will give the wall stack duct some added rigidity as short drive cleats dont stiffen it up much. Wouldnt hurt to add foil tape to the joints...
Does the hsi glow red hot during the operation? That should happen next. Then, gas valve clicks open, flame sensor keeps gas valve open, low limit initializes, blower kicks on...
Yeah that definetly looks like a 1st year installed that. Its cute. Instead, Install a 90 right off the bath fan outlet aimed at the jack. Then aim another 90 from the jack to the bath fan 90. Add another elbow (<90) to make up any difference needed. Foil tape or duct seal pipe joints. Wrap with...
Funny things happen when boards go faulty. The tech isn't out to lunch considering replacing it. The part does cost around $200. I've also never heard of a high limit opening prematurely. The blower running unnecessarily is something that keads me to the board.
Hey ya'll. i bought and installed some blackout roller blinds on the inside of my besroom window frames. The problem is light still pours in on the sides. I'm looking for some sorta plastic angle lengths or tracks that I can stick onto the sides of the frames. I am thinking of something along...
Thanks fir that Wuzzat. Ya I found the part 50a65-843 for only $100, but amazon.com doesn't ship north of the border. I grumbled and paid double, but at least the wife is happy(and cool) again.
Thanks for your help guys. I figure it is the relay, but I lack the expertise to locate a replacement, detach and solder on a new one. Where is a good online place for relays? I will keep the old one and get a buddy to solder on a new relay, and then I will have a backup board. I replaced the...
I am only getting 15v ac out from my board to the blower motor. Blower motors leads had a resistance in the 7ohm range. Blinking diagnostic was 'idle/waiting' position. when I turned stat up for a call for heat, inducer would turn on, then burner, then high limit and shut down no blower.
Do any...